Battery Telemetry
1. The R168 has built in voltage telemetry for your main flight battery or any battery up to 18v. Connect the
positive electrode of the battery to the BATT interface to so the telemetry sensor can take a voltage reading.
Note the ground circuit must be on the same circuit as the battery being read.
2. Please follow the below diagram. Please DO NOT connect the BATT sensor to a battery greater than 18v or
the receiver will be damaged.
To enable the telemetry function on your radio, navigate
to the telemetry page and select "Discover New
Sensors" to scan for sensors currently on the receiver.
Ensure you calibrate the voltage of the sensor. Select the
RxBt option and follow the popup menu. Adjust the ratio
parameter until the displayed voltage matches the actual
voltage of the battery being read by the receiver.