Download Print this page

Ametek TELGUARD TG-PEM Quick Install Manual page 2

Advertisement

Use the three provided mounting screws to secure the TG-PEM
board onto the bracket.
5. Connect the TG-PEM to TG-7 or TG-7FS
Make sure there are no AC or DC power sources
connected to the TG-7 or TG-7FS. Connect power and
ground from the TG-PEM terminal labeled "TELGUARD
POWER" to the terminal block on the TG-7 or TG-7FS
labeled DC and GND. Do not overtighten.
Connect ribbon cable (provided) from the connector on
TG-PEM labeled "TO HOST" to the 3x2 6-pin header on
the TG-7 series board as shown. The dark color edge of
REFERENCE:
TO HOST TO TG-PEM
1
C
2
Note: At power-up, both LEDs will be on for 3 seconds then off for 3 seconds.
3x2 6-pin header
Dark edge on right
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8
TG-7FS
LTE
```
DC
STC2 STC1 TRIP
BATT
AC
DC GND
D1 D2
Reset
TELGUARD
POW ER
ZONE INPUTS
3
C
4
5
C
6
7
C
the ribbon cable should be oriented away from the
antenna of the TG-7 or TG-7FS.
6. Power Up and Configure
Connect power and ground from the panel
auxiliary output to the terminal labeled "PANEL
POWER" on the TG-PEM to provide power to the
TG-PEM and TG-7 or TG-7FS.
Complete the activation of the TG-7 or TG-7FS as
outlined in the TG-7 series manual.
If the TG-PEM was preconfigured, it should now
be ready; otherwise, visit www.telguard.com to
configure the TG-PEM.
When the TG-PEM is configured and ready, LED
D2 will be either solid amber (in power supply
only mode) or solid green (in power supply and
zone extender mode).
7. Connect Zone Inputs (if using)
Temporarily disconnect the power while you
connect any monitoring sensors to the zone
inputs.
For supervised zones, use a standard 2.2kΩ EOL
resistor (not included).
Reconnect power, allow the TG-7 or TG-7FS to
initialize, and check for proper operation.
Optional: Second TG-PEM Installation
See full Installation Manual for mounting and wiring
instructions.
POW ER
PASS THRU
PANEL
POW ER
8
LED
LED
STATUS
D1
D2
Ready, no
Off
Green
activity
Off
Off
Shut down
Amber
Communicator
Any
flash
activating
At least one enabled input is
Reportable
Red
Green
tripped or event(s) captured
event
Red
Event(s) reporting or waiting
Event
Green
flash
reporting
Red
Bootloader
Off
flash
error
Power supply
Off
Amber
only or
Not ready
DETAILS
TG-PEM is ready
Power to TG-PEM is below
minimum
TG is being activated
and waiting to be reported
for response
Device failure, contact
Technical Support
Power supply mode,
TG-PEM waiting for
configuration, or
Communicator not enabled
56051801 – Rev A

Advertisement