Step
5
Release the discharge
pipe thermistor.
Pull out the outdoor
6
heat exchanger
thermistor.
Cut the clamp.
7
Unfasten the hook from
8
the partition plate with a
flat screwdriver.
Removal Procedure
Procedure
Discharge pipe thermistor
Clamp
Removal of Electrical Box / PCBs
Pay attention so as not to
lose the fixture for the
thermistor.
When reassembling, do not
insert the thermistor up to
the dent of fixture.
Dent
(R18744)
Pay attention so as not to
lose the clip for the
thermistor.
Outdoor heat
exchanger
thermistor
(R18745)
(R7395)
The electrical box can be
removed by lifting itself
without a screwdriver.
(R7318)
Points
Fixture
(R18746)
Clip
(R18747)