  • Page 1 MSI3750CS-5 RF Digital Weight Indicator CellScale System ® a component of the User Guide Measurement Systems International...
  • Page 2: Table Of Contents

    ID Code String 1 & String 2 ............34 6 – T ............35 ECTION OTAL TATISTICS Total .....................35 Auto Total ..................35 Total Menu (Setup Total) .............36 View Total ..................38 Clear All Totals ................39 Alternate Clear Total Methods ............39 Statistics ..................39 Page 2 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 3: Introduction

    MEASUREMENT SYSTEMS INTERNATIONAL INTRODUCTION The Measurement Systems International MSI 3750CS RF Weigh Meter is an element of MSI's CellScale System. ® Combined with 1 or more CellScales, the 3750CS provides complete control over all scale and data functions. The 3750CS serves as a remote terminal for any CellScale and has no internal measurement capability. One 3750CS can read the output of many CellScales, and 1 CellScale can also provide data to many 3750CS'.
  • Page 4: Features

    Set Point Relay outputs are available for Set Points 1-8. Set point management is performed by the CellScale, which has 32 programmable set points. The 3750CS has independent set point reaction (relays, messages, display modes, comm port outputs, etc.). Page 4 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 5: Section 1 - Unit Installation

    .5A at 24V. Fast blow or medium blow fuses are acceptable. White, Black, and Green – These are reserved for control functions used in specials. Usually these should be insulated and not wired anywhere. Please consult MSI for more information. TOTALIZE SWITCH OPTION When equipped with the totalize switch option, the user is responsible for providing a SPST (single pole, single throw) momentary switch.
  • Page 6: 3750Cs Table Mount

    Brown (TD) White (RTS) Grey (CTS) (NC) 9 9 (NC) Blue (GND) Blue (GND) 9-Pin Female ‘D’ 9-Pin Male ‘D’ Solder Cup View Solder Cup View 3750CS TABLE MOUNT 3750CS WALL MOUNT Page 6 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 7: Rf Scale Communications

    The Master transmits a sync pulse on a regular basis, providing synchronization of all remotes in the designated Network. Thus it forms the center of a cell. MSI provides four products capable of being the master unit: the CellScale, the CellModem, the 9300 Porta-Weigh+ Crane Scale, or the Trans-Weigh 6260CS Crane Scale. Up to 16 slaves can access the master unit.
  • Page 8: Antennas

    4) For maximum range, a 14dBi Gain Yagi Antenna is available by special order. Please contact MSI for details. 5) Corner Reflector – Often the best choice for a wall mounted antenna.
  • Page 9: Long Range Omni 9Dbi Antenna W/ Pipe Mount

    The Long Range Omnidirectional antenna (MSI P/N 12147) is pole mounted (up to 2” diameter) and extends the range of CellScale transmissions. MSI supplies this antenna with a 10’ (3m) coax cable pre attached. This antenna must be vertically mounted. The vertical Beamwidth (-3dB point) is 14 degrees. Also available with an N connector (MSI P/N 12037) for applications requiring longer coax cable lengths.
  • Page 10: Yagi Antenna

    VEHICLE MOUNT WHIP ANTENNA 9 dBi Corner Reflector A vehicle mount whip antenna is approved for use with MSI CellScale equipment and is avail- able by special order. This 5 dBi gain whip is rugged and waterproof and mounts in a 3/4” hole on the roof of mobile vehicles.
  • Page 11: Standard Antenna Bulkhead Extensions

    Standard 1/2 Wave Dipole, Patch Antenna, Vehicle Whip, or Long Range 9dBi Omni: The field strength radi- ated by any one of these antennas, when connected to MSI RF products, may exceed FCC mandated RF exposure limits. FCC rules require professional installation of these antennas in such a way that the general public will not be closer than 20 cm from the radiating aperture of any of these antennas.
  • Page 12: Rf Network Setup

    Defaults to 10 seconds. Entering 0 turns off the Time-out timer. MSI recommends at least a 5 second timeout period to handle small lapses in transmissions. The system defaults to 10 seconds.
  • Page 13 High Power, 1 equals Med Power, 0 indicates Low power. ENERGY 12) Press the 0, 1 or 2 key as needed. MSI recommends using high power (2) in most installations. 13) This completes the MODEM setup. Push the EXIT key to return to normal scale operation.
  • Page 14: Configuring For Multiple Networks

    Up to 5 addresses can be programmed. NET 1 The 3750CS uses 55-555 as a place keeper for empty NET addresses. NET 2 8) Push the EXIT key after all needed RF Networks are set up. Page 14 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 15: Interpreting The Rf Bar Graph

    (Phantom) network, try switching both the master CellScale and the 3750CS remote to another unused Network. MSI advises avoiding Network #0 when possible, as this is the Modem default, and therefore most likely to be found on units not properly set up.
  • Page 16 FIRMWARE VERSION NOTICE This User Guide is intended for CellScale equipment that uses MSI’s next generation of RF Modems. This guide applies only to 3750CS Indicators manufactured after 5/1/06. There are menu differences and feature additions not found in first generation CellScales.
  • Page 17: Section 3 - Scale Operation

    Multiplexer and provide individual wheel loads. Index position 5 shows front axle load, index 6 shows rear axle load, and index 7 shows total weight. The CellScale allows the user to name each channel and the name can appear Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 17...
  • Page 18: To Access Multiple Channels

    The SC INDEX steps from channel to channel as dictated by the Scan list stored in the CellScale. If the CellScale has only one scale channel defined, this procedure is not necessary. This is always the case for MSI- 6260CS Crane Scales and other single load cell systems.
  • Page 19: Setup Zero

    2) Push TARE again. Assuming no motion, the display temporarily reads “TARE SET” and then converts to a “NET” display. All following readings are devia- tions from the set Tare value. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 19...
  • Page 20 Tare Register. The display reads “TARING” followed by “TARE SET” and displays the Tare value for 1 second. All subsequent readings have the Tare value subtracted and are displayed in “NET” weight. Page 20 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 21: Setup Tare

    NET). The “ON TOTAL” setting clears the Tare Value after the load is totaled. The default for the “AUTO CLR” function is “DISABLED” . When disabled, the Tare Value can only be cleared manually (see “To Clear Tare and return to Gross Mode”.) Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 21...
  • Page 22 6) Push ENTER. The AUTO CLR is now enabled and ENABLED the 3750CS is back in the SETUP TARE menu. 7) Push EXIT to return to normal scale operation (with AUTO CLR the AUTO CLEAR TARE function enabled). Page 22 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 23: Net/Gross

    If working with an ID Code present the ID Name will return to the message display after the “GROSS” or “NET” message shows. 2) Pushing NET/GROSS again will revert the display to the NET mode. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 23...
  • Page 24: Units

    2) Turn on the Peak Hold mode by pushing the selected FUNCTION key. The display reads “PEAK NET” or “PK GROSS” to indicate peak hold mode is enabled. The display will only update when a greater value than previously recorded is detected. Page 24 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 25: Print

    EXIT twice to return to normal scale operation. All inactive channels will now be INACTIVE skipped. If all channels are inactive, the 3750CS weight display will be blank. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 25...
  • Page 26: Section 4 - Function Keys

    MSI can supply custom labels on request. For example, if the String 1 function is to be used to input a customer number, MSI can supply a label that reads “CUSTOMER”.
  • Page 27 STRING1 STATS 8) Push EXIT (SETUP) twice to return to normal scale SETPOINT operation, or assign another Function key using steps 3-6. ASSGN F5 Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 27...
  • Page 28: Id Codes

    • ID Codes are alphabetized when created using the standard ASCII convention. • The 3750CS provides a way to scroll through all existing ID Codes as an alternate means of selecting an existing ID code. ID CODE ORGANIZATION Page 28 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 29 LCD. However, when the ID Code is printed or transmitted to a computer, the proper lower case character will be sent. Font Substitutions: “F” for “f”, “P” for “p”, “X” for “x”, Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 29...
  • Page 30: Using Id Codes

    TESS 7) Push the STU7 key twice to get the “T” to appear. TEST 8) Push the SPACE 0 key to input a space. TEST_ Page 30 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 31 ID Code “567”. Total readings will be added to any existing totals previously stored on ID Code “567”. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 31...
  • Page 32 It can take a while to clear all the registers. The 3750CS indicates “WAIT” while this is occurring. Once finished deleting, the 3750CS returns to the WAIT scale mode with the default ID code activated. Page 32 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 33: Setup Id Codes

    6) The display reads “ID NAME”. Press EXIT to ...to finalize edit. ID NAME return to normal weighing mode or press UP or DOWN to reach the next selection. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 33...
  • Page 34: Id Code String 1 & String 2

    ® during the text entry process). Each string can be up to 20 characters in length. The MSI “@ codes” can also be embedded in the string which provides an extremely versatile output capability. See Section 7 – Comm Ports, for more details on programming “@ codes”.
  • Page 35: Section 6 - Total / Statistics

    Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 35...
  • Page 36: Total Menu (Setup Total)

    Another example: On a scale with a capacity of 1000 kg the user desires to Auto Total all weight that exceeds 50 kg. Since 50 kg is 5% of 1000 kg, the Total Threshold is set to 5%. The Threshold is entered in 1% increments. Page 36 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 37 7) Push the EXIT key to return to normal scale opera- tion. Auto Total is now enabled. The small “AUTO ∑” annunciator will appear. ∑ THRESH Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 37...
  • Page 38: View Total

    2) Press ENTER. The last weight totaled is subtracted and the number of weighments counter is reduced by one. If you change your mind, push EXIT to cancel the Clear Last Total opera- tion. Page 38 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 39: Clear All Totals

    ID Codes and provides the following information: GRAND TOTAL, Number of Totals, and the Overall Average (GRAND TOTAL divided by Number of Totals). Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 39...
  • Page 40 1) Push GRAND TOTAL. Displayed is the Grand Total obtained by adding the totals of all ID Codes. 2) (Optional) Push PRINT. The Grand Total and Grand # of samples will output to CommPort 1. Page 40 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 41: 3750Cs Meter Setup

    EXIT Not all the selections above are activated on every MSI 3750CS. Legal-for-trade issues and application issues require certain menu items to be under the Calibrate menu (under seal, see calibration section), and certain items to be disabled. Any or all menu items can be eliminated under software control (contact factory for details).
  • Page 42 9) WT TYPE – Displays “GROSS” or “NET” and other weigh mode types. 10) SC INDEX – Displays the Scale index, used in multichannel CellScale systems. 11) LC NUMBER - Displays the A/D channel and sub channel of the currently addressed CellScale. Page 42 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 43: Real Time Clock / Calendar

    You are back in the Set Sub-menu. 8) Push EXIT twice to return to the TIMEDATE sub- menu. Push EXIT again to return to normal scale operation. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 43...
  • Page 44: Setup Power Menu

    Operating the Clock from a battery powered MSI 3750CS has very little effect on battery life. The LCD and LCD drivers use only minimal power. The µP is only awake long enough to update the LCD so its average power consumption is small. Using the /MIN mode selections minimizes the µP power drain.
  • Page 45: Bar Graph Menu

    The 3750CS defaults to the MODEM setting of the Bar graph. The following procedure shows how to set up the Bar graph for PER CENT operation. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 45...
  • Page 46: Lock

    For added security an optional lock code (1-4 characters) can be entered. Once the MSI 3750CS is locked the message “LOCKED” will appear whenever a locked function is tried. To unlock push SETUP NET/GROSS and enter the lock code number.
  • Page 47 Use the LEFT / RIGHT keys to change the lock status. SETUP 7) Push EXIT (SETUP) to return to the Lock Menu, or push EXIT again to return to normal scale opera- tion. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 47...
  • Page 48 Unlocking is the same process as locking. Follow the Lock procedure above to unlock. The only difference is at step 5, the message “UNLOCKED” will appear. Unlocking does not change the Lock Mode parameters, so if no changes are needed, you do not need to enter the “LOCKMODE” menu. Page 48 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 49: Ection 8 - Set Points

    6) Send a message out the RS-232 port of the 3750CS (Set Points 1-32). This message can include weight parameters, time, date, and any random text the user requires (using MSI @ codes). These actions are independent of what the CellScale does, and are independent of other 3750CS’s that might be on the Network.
  • Page 50: Set Point Setup Menu

    Used to disable and enable all 32 Set Points at once. This parameter is stored in the CellScale, and therefore any 3750CS can disable the Set Points for the entire Cell. CURRENT SET POINT (CURNT SP) Page 50 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 51 Total or n Total Set Point. SET POINT STRING (SPSTRING) Up to 20 characters are stored for each Set Point (1-32). These characters form the Set Point Message associated Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 51...
  • Page 52: Example Set Point Programming

    ® The 20 characters can include MSI “@ codes” that allow Set Points to include in their message such characteris- tics of current weight, date, time, and any additional data required. This can form the basis of a powerful main- tenance tool.
  • Page 53 EXIT (SETUP) key to return to normal 200_ scale operation. VALUE 1 Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 53...
  • Page 54 This is the menu which defines how the two thresh- olds relate to each other. OP RELAT 14) Push ENTER. The message reads the current operator relationship which defaults to “NONE”. NONE Page 54 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 55 Set Point, continue on to any or all of the following procedures or push the EXIT OUT DEST (SETUP) key to return to normal scale operation. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 55...
  • Page 56 To Program the Local 3750CS Set Point Message Set Point messages are entered as ASCII “Strings”. You can combine MSI “@ Codes” in embed weight, date, and time information in the Set Point string. See the Comm Port section following for a table of “@ Codes”.
  • Page 57: Relay Output Option

    RELAY OUTPUT OPTION This option adds 7 SPDT Relays and 1 Logic Level output to the MSI 3750. The relays can be used in conjunction with alarms, motors, and other control circuitry to provide a complete automated production line, or to provide additional information to the scale operator.
  • Page 58 In figure 5 two relays are combined to turn on a motor when either Set Point is true. One major application for combining relays is to use one for a master start/stop for all the other relays. Page 58 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 59 Values of 1kΩ to 4.7kΩ usually will suffice. There are two complementary outputs as shown in Figure 7. The TTL Hi output goes high when the set point is tripped. The TTL Low output goes low Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 59...
  • Page 60 Besides providing a direct logic output to PLCs or other controllers, the logic output can be used to drive external relays. Figure 8 shows an example of the logic output driving an external N-channel MOSFET which can turn on a high-power relay. Figure 8 Page 60 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 61: Ection 9 - Communication Ports

    SECTION 9 – COMMUNICATION PORTS INTRODUCTION • The MSI 3750CS is equipped with a single RS-232 serial input/output and a Real Time Clock/Calendar. The Comm Port is intended for interfacing printers, data loggers, scoreboards, and computers to the 3750CS Meter.
  • Page 62: Comm Port Parameters

    2) Computer Control: The computer can control and receive data from the MSI 3750CS through the use of simple ASCII commands. These commands can be sent through the use of a data communications terminal, or a custom computer pro- gram.
  • Page 63: Comm Port 2 Setup Parameters

    To use this versatile feature, the user must input com- mand codes and data in a specific manner. Each command code consists of a 2 letter mnemonic. Some command Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 63...
  • Page 64: Example Printer Formatting

    Using formatting controls typical to modern bar-code printers is simply a matter of formatting the printer strings. The MSI 3750CS character set includes all upper case letters, lower case letters, numbers, and most of the rest of the standard ASCII set.
  • Page 65: Programming The End Of Line String

    Input Data Form With the exception of characters following the command “@” symbol, all characters are treated as printable text or control characters. The MSI 3750CS represents characters that can’t be displayed on the LCD with a “ “. º...
  • Page 66: Serial Output "@" Commands

    “x” spaces are output limited to 99. For more spaces use two @B commands in series. Note: For spaces fewer than 5, it is more memory efficient to enter spaces instead of the @B command. Example - Building on the previous example, we’ll center the “MSI 3750CS” on a 20 column printer: @B06å4åMSI3750åå5º...
  • Page 67 “@H”. Output Data Form: “x” tabs are printed (limited to 99). For more tabs use two @H commands in series. OUTPUT RF MODEM ID Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 67...
  • Page 68 Length: 6 Justification: left N E T Length: 6 Justification: left T A R E Length: 6 Justification: left T O T A L Length: 6 Justification: left T - C N T Page 68 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 69 Length: 11 Justification: full, leading hours zero suppressed 1 4 : 0 8 Length: 5 Justification: left, leading hours zero suppressed 1 4 : 0 8 : 3 6 Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 69...
  • Page 70 Lower Display combined with Lower Display Mode. Last totaled weight Note: will print dashes if no weight has been totaled. Output Data Form: 2 0 . 0 1 5 * * * * * * Page 70 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 71 @X1 @X2 @X3 @X4 @X5 @X7 - 2 0 . 5 0 2 Length: 8 Justification: right justified 1 2 3 4 5 6 7 . Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 71...
  • Page 72 Use the @# (where # = 0-31) commands in conjunction with the @Vx or @Wx commands to cause the print string to take data from any scale channel listed in the Channel List. See the CellScale manual for information Page 72 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 73: Computer Operation Via Host Codes

    COMPUTER OPERATION VIA HOST CODES The MSI-3750CS can interface to computers via RS-232. All functions can be controlled remotely and all setups can be downloaded automatically. The computer can query the scale at any time to get status, weight, or accu- mulated totals.
  • Page 74 13= Pk Hld off 7= View Total Tu r n o n t h e None Clock mode must be enable with seconds. Power Delay at least 200 ms before sending additional data. Page 74 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 75 4= Message S e t P o i n t Enter up to 20 characters Terminate string with semicolon. You can String embed @ commands. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 75...
  • Page 76 1= Upper Case If your printer prints lower case letters select Mode 2= lower case Set Units 1= lb. 5= oz 2= kg 6= g 3= tons (short) 7= daN 4= metric tons Page 76 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 77: Ection 10 - Cell Scale Calibration

    A full calibration must follow this operation. The second procedure returns all the 3750CS registers to defaults. However calibration in the CellScale is unaffected. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 77...
  • Page 78 (Next Test Wgt) Zero Cal SPAN Cal ERROR ERROR Too much Too little or dead load or INPUT VAL too much offset in the TEST weight on the load cell. scale. WEIGHT Page 78 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 79: Reset Calibration

    4) Push ENTER to reset all registers. The display will initialize while the registers are cleared. If you change your mind, pushing EXIT will cancel the Reset All operation. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 79...
  • Page 80: Calibrate Setup Menu

    “OIML” for European L-F-T applications. “METRIC” is the same as “INDUSTRY” except only kg and g units are enabled. Before starting the following procedure, you must be in the Top Menu Level of Calibration. See “Enable Calibration”. Contact MSI for details on the differences between the various configurations.
  • Page 81: To Calibrate

    CAL’ING “CAL’ING”. Wait for about 5 seconds. If the detected zero weight is within acceptable limits the message WEIGHT 1 “WEIGHT 1” will appear. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 81...
  • Page 82: To Enable / Disable Azm (Auto Zero Maintenance)

    AZM enabled. Disabling AZM will degrade temperature and drift performance of the CellScale. Also use caution in setting the AZM window too large. This can cause the scale to zero unexpectedly. MSI recommends keeping AZM below 5d for most applications. Page 82 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 83: Motion Band

    4) After entering the desired motion band, push MOTNBAND ENTER. 5) Push EXIT to return to normal scale operation, or push UP or DOWN to choose another Calibrate Setup function. Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 83...
  • Page 84: Center-Of-Zero (Coz) Indicator

    MSI, please contact MSI for details on determining the active weight. The MSI weight is found on MSI’s serial number tag. It is referenced as the “COMP WEIGHT” and is usually measured in pounds. Make sure you convert this weight if the scale is calibrated in units other than pounds.
  • Page 85 70 kg. MSI WT Make sure that the MSI WT is in the displayed units. If not convert the MSI WT to the calibration unit as shown on the display. 13) Push ENTER to store the MSI WT.
  • Page 86: Ppendixa - Menu Aps

    UNITS SC INDEX ID NAME TOTAL ID NUMBR ID CODE TEST GRNDTOTL CH NAME STRING 2 SETUP CLRLAST∑ STRING 1 2KEYCLR∑ STATS 1KEYCLR∑ SETPOINT CLRLATCH LOWER DISPLAY PEAKHOLD DISABLED MENU RF NTWK Page 86 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 87 MEASUREMENT SYSTEMS INTERNATIONAL UNIV TAR Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 87...
  • Page 88 3750CS CALE RF DIGITAL WEIGHT INDICATOR ® Enter 1 1-254 Enter up to 255 Characters Enter 1 Character Enter up to 8 Characters Page 88 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 89 8 HOURS PWR VEHI 4 HOURS PWR AC 2 HOURS POWER AUTO 1 HOUR SETUP POWER 30 MIN LIGHTING 10 MIN DISABLED AUTO OFF EXIT Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 89...
  • Page 90 3750CS CALE RF DIGITAL WEIGHT INDICATOR ® Page 90 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 91 MEASUREMENT SYSTEMS INTERNATIONAL Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 91...
  • Page 92: Ppendixb - Ascii Chart

    3750CS CALE RF DIGITAL WEIGHT INDICATOR APPENDIX B – ASCII CHART ® Page 92 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 93: Ppendixc - Specifications Ummary Of Eatures

    Networks. or sirens. 7 SPDT (form C) 1A/115VAC relays are provided SC Index: Switch between selected scale channels Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 93...
  • Page 94 A 9dBi gain antenna with a 10’ (3m) low loss coaxial cable. for blind check-weighing. Can also be configured as a totalize Increases transmission range and allows for remote locating the alert. Antenna. Mounting Bracket Page 94 MSI-3750CS-5 RF Weighmeter • User Guide...
  • Page 95: Ppendixd - Internal Iring

    MEASUREMENT SYSTEMS INTERNATIONAL APPENDIX D – INTERNAL WIRING Software V2-21 or greater, 2nd Generation Modem ® CellScale System • 3750CS-5 User Guide Page 95...
  • Page 96: He Msi Limited Arranty

    THE MSI LIMITED WARRANTY MEASUREMENT SYSTEMS INTERNATIONAL, INC., WARRANTS load sensing elements and meters against defects in workmanship and materials for a period of one year from date of purchase and warrants electrical cables and batteries against the same defects for a period of ninety (90) days from date of purchase.

Table of Contents