Routing Power Cables

Note: Continuous metal conduit should be used for all power cables to reduce radiated
electromagnetic interference (EMI). The conduit must be securely grounded to the
converter enclosure and the motor case. Conduit hubs should be IMC or rigid steel conduit
and be UL listed. Conduit hub locations can be seen in Figure 15 - Figure 19.
Route power cables through the supplied openings in the bottom of the enclosure, using
appropriate conduit or strain relief devices.
Important Note: If new openings are cut, be sure to completely remove all resulting metal
shavings.