8. SYNCHRONIZATION
As soon as the barriers are switched on they synchronize in a time between 1 and 10 seconds. If syncronization is OK
the Buzzer (make sure that is enabled, dip1 receiver On) after some seconds becomes OFF. If it doesn't happen (buz-
zer already on) verify the setting of range and the proper mechanical alignment of the barriers.
After the syncronization the led on the receiver flashes to indicate the quality of reception: see table.
1 flash
2 flashes
3 - 4 flashes
9. FUNCTIONING
Every receiver checks the direct beam and the oblique ones (upper and lower), this ensures the protection against false
alarms caused by small objects and bugs.
10. RISOLUZIONE DEI PROBLEMI
PROBLEM
led doesn't blink
false alarms
TABELLA QUALITA' RICEZIONE
bad reception
good reception
perfect reception
CAUSE
difficult initialisation
difficult reception
sun hitting the receiver
interference
operation not optimal
sufficiently good operation
optimal operation
SOLUTION
check alignment
verify presence of obstacles
switch off and on again
increase range and supply again
verify alignment
verify presence of obstacles
increase range and supply again
increase range and supply again
if TX is not hitten by the sun, invert positions of TX and
avoid using remote controls or other devices using
emitting infrared rays close to the RX
RX