5. TRANSMITTER DIP-SWITCH CONFIGURATION - RANGE ADJUSTMENT
DIP - SWITCH
DIP
1
5 LINES
(FIG2):
off
DIP
off
off
on
DIP 4
⇒ on antiremoval and anti-opening disabled
DIP 5
6. TRANSMITTER CONFIGURATION DIP-SWITCH: SETTING OF OPTICAL NUM.
DIP - SWITCH 3 LINES (FIG.2):
Attention:
after the configuration of DIP, power OFF and then power ON
the barriers to confirm the configuration
DIP 1
DIP 2
Off
Off
Off
Off
7. RECEIVER DIP-SWITCH CONFIGURATION:
DIP - SWITCH:
1
2
Creep zone (terminals opposite side) disa-
3
4
5
6
* This function is used to allow small pets to pass through a protected window or door, when the alarm system is
armed.
** This parameter reduces the reaction time of the Active IR beams, therefore it is suggested to use it with care and in
places not directly exposed to sunbeams.
*** The plugs are not completely waterproof in order to avoid condensed water to stay inside and allow the beams to
transpire.
DIP
DIP
INDOOR
2
3
0.5 ⇨ 6 m
off
off
6 ⇨ 8 m
off
on
8 ⇨ 12 m
on
on
12 ⇨ 15 m
off
off
⇒ on antiremoval disabled
DIP 3
N° OTTICHE
Off
Off
Off
On
On
Off
On
On
OFF
Acoustic signalation (buzzer) disabled
Creep zone (terminals side) disabled
bled*
normal sensitivity
Anti-opening and anti-removal enabled
Anti-removal enabled
OUTDOOR
0.5 ⇨ 2 m
2 ⇨ 4 m
4 ⇨ 6 m
6 ⇨ 12 m
⇒ off antiremoval and anti-opening enabled
DIP 1
2
On
3
On
4
On
5
On
Creep zone (terminals opposite side) enabled*
OUTDOOR WIHT SUN
0.5 ⇨ 2 m
2 ⇨ 3 m
3 ⇨ 6 m
6 ⇨ 10 m
⇒ off antiremoval enabled
DIP 2
DIP 3
Off
Off
Off
On
On
Off
On
On
ON
Acoustic signalation (buzzer) enabled
Creep zone (terminals side) enabled*
High sensitivity**
Anti-opening and anti-removal disabled
disabilitati
Anti-removal disabled
N° OTTICHE
6
7
8
8