INSTALLATION AND COMMISSIONING
GLOBAL PARAMETERS CONFIGURATION
Once that local parameters are set, the global parameters must be configured to ensure an optimum performance of
the unit. Consult the instruction manuals of the monitoring system for further information.
PAIRING WITH A U·vision UNIT
This unit is equipped with a wireless connection so that it can be paired with a U·vision or U·vision
Consult the U·vision instruction manual for further information.
INDICATOR LEDS AND DIAGNOSIS FUNCTIONS

INDICATOR LEDS

While the unit is in standby mode (the unit is online but not dispensing fluid), the following parameters can be checked:
• Press and hold F1 button to show the installed firmware version in the display.
• Press and hold F2 button to show the power supply voltage ( in volts).
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
INDICATOR
STATUS
ONLINE LED
Blinks there times U·vision unit paired
E.O.L. LED
S.V. ON LED
Blinking
BY-PASS LED
Blinking
DISPLAY
DISPLAY
DISPLAY
* Only U·valve + model.
Off
CAN cable not connected or CAN BUS ERROR
On
CAN cable correctly connected
Off
Not configured as end of line
On
Unit configured as end of line
Off
Solenoid valve closed
On
Solenoid valve open
Malfunction of the solenoid valve
Off
By-pass mode off
On
By-pass mode activated
Malfunction of the solenoid valve
Wifi connectivity not available*
C
Wifi configuration mode*
"C"
"C" Blinking indicates that wifi configuration is
being transmitted to the unit*
+
gun.
INDICATION
R. 02/20 838 844
EN
5