Page 7
Installation manual Blokhus (Extension modules & HE-module) Dear user Safety instructions Congratulations on your purchase of a Faber fire! A Please note! quality product from which you will experience warmth and atmosphere for many years. We It is advisable to always install a screen for the...
Through a wall or façade, use a Faber wall outlet. Depending on the flue calculation this can be 100/150mm or 130/200mm. C31, outlet via roof For a (flat) roof, use a Faber roof outlet with a diameter of 100/150mm. 7 < <...
Page 9
Take into account the installation requirements fireplace for connecting the control unit. (see chapter 3). Place the fireplace at the right place and level it. See fig. 1.8a for the wiring diagram of the Blokhus: A= Adapter (6V) Please note!
Installation manual Blokhus (Extension modules & HE-module) Removing glass Divide the ash material between the logs, don’t cover the air intake (the perforated parts at the back). 5.1 Front glass Remove the front panel. This is possible Please note!
Page 11
Cleaning Wall terminal has the correct Remove the front glass (see chapter 5). position and side up; You can clean the glass with Faber glass polish. Roof terminal has the correct This is a specially formulated cleaning agent that position.
Page 12
Installation manual Blokhus (Extension modules & HE-module) 11 Flue calculation Horizontal length: A simple way to calculate whether the exhaust The Horizontal Length consists of the configuration is possible in combination with your elements H, J, L, M, P and R fireplace, use the “Faber Flue App V2”:...
Page 16
Installation manual Blokhus (Extension modules & HE-module) 13 Calculation sheet Starter length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Bend 90°...
Page 17
Installation manual Blokhus (Extension modules & HE-module) found value Search in the table at TVH and THL and enter the value that is found. ……………………………… If the detected value is a number, check whether the completed STL is higher or equal to the value in the table.
Installation manual Blokhus (Extension modules & HE-module) 14 Technical data Technical data Type indication(s) Blokhus Type appliance C11/C31/C91 Diameter outlet/inlet 100/150 Gas connection 3/8" Indirect heating functionality Category II2H3+ Symbol Unit Reference gas/inlet pressure G20-20 G30-30 G31-37 mbar Emissions in space heating...
Page 19
Installation manual Blokhus (Extension modules & HE-module) 15 Outlet position Please note! These rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with the applicable rules as defined in the building regulations.
Page 29
Installation manual Blokhus (Extension modules & HE-module) 19.1 Installation requirements Remove the upper panel of the fire by loosening screws A (fig. 1.0). The distance between the top of the appliance to the ceiling must be at least Installation instructions 250mm.