Download Print this page

Faber Blokhus Installation Manual page 9

Extension modules & he-module

Advertisement

Installation manual Blokhus (Extension modules & HE-module)
4.2 Electrical connection
Install a 230VAC/50Hz wall socket near the
fireplace for connecting the control unit.
See fig. 1.8a for the wiring diagram of the Blokhus:
A= Adapter (6V)
B = LED Symbio-Module
C = Receiver
D = Ignition pin
E = Gas valve
See fig. 1.8b for the wiring diagram of the Blokhus
with I.T.C.:
A= Adapter (6V)
B = LED Symbio-Module
C = Receiver
D = Ignition pin
E = Gas valve
F = I.T.C. (Intelligent Technical Controller)
4.3 Smart Home installation
Please note!
This is only possible if the fire is equipped
with I.T.C!
The controller can be connected to an external
source, such as a Domotica system, by using a
Faber Interface Unit (article number A9323000).
4.4 Preparing the fireplace
Remove the fireplace from its packaging.
To do this unscrew the nut and bolt at the
bottom of the appliance.
Remove the front glass (see chapter 5)
and any mouldings, store them at a safe
place and remove the packaged parts
from the fireplace.
The included wall bracket (fig 1.9) is only
for use with the optional extension
module(s). See chapter 19 until 21.
Prepare the gas connection on the gas
valve.
If necessary, the lower and upper panel
can be removed. To do this, loosen the 2
bolts on the inside, lift the panel slightly
so that it can be moved forward (fig. 1.6-
B). The middle panel is already loose. This
is the access for the gas control unit.
8 <
<
<
<
4.5 Positioning the fireplace
Take into account the installation requirements
(see chapter 3). Place the fireplace at the right
place and level it.
Please note!
The fireplace can be levelled with the 4
adjustable feet in the bottom plate (see fig.
1.6-C). Use an Allen key 5 for this.
A wall bracket is supplied as standard with the
appliance, see fig. 1.9. Only use these in
combination with the optional extension modules,
see chapter 19.
4.6 Installing the flue pipes
Install the flue pipes according to the installation
manual supplied with the appliance (40011968)!
For fitting the flue pipe on the fire the top
plates can be removed (fig. 1.7).
The distance to combustible materials
must be min. 50mm, calculated from the
outside of the flue pipe.
Never start immediately with length-
adjustable concentric flue pipe on the
appliance.
Horizontal sections should be installed to
allow a slope towards the appliance
(3 degrees).
Built the system from the appliance. If this
is not possible you can make use of an
extendable adapter section.
For fitting of the flue system, the 0,5m
length-adjustable pipe must be used.
Make sure that the inner pipe is always
15mm longer than the outer pipe. Wall-
and roof terminal can also be cut. These
components must be secured with a self-
tapping screw.
Options:
For the installation instructions of the
optional extension modules and the HE-
module in combination with the flue pipes
see chapter 19 until 21.
Please note!
Only 1 HE-module may be used!

Advertisement