EVAP
AIR
75
Capacity
Total
MBtuh†
Sys
CFM
EWB
Total Sens‡
kW**
552AN060-F Outdoor Section With CK5A/CK5BA060 Indoor Section
72
66.5
32.5
4.51
67
62.4
41.9
4.44
1600
63†† 55.7
39.9
4.33
62
54.4
49.4
4.31
57
51.3
51.3
4.25
72
67.2
33.5
4.60
67
62.9
43.6
4.52
1800
63†† 58.6
42.9
4.46
62
57.5
53.4
4.44
57
54.7
54.7
4.39
72
67.6
34.3
4.68
67
63.6
45.4
4.61
2000
63†† 60.3
45.2
4.56
62
59.7
57.0
4.55
57
57.8
57.8
4.52
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CD5PX
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
CK5PA
060
CK5PT
060
CK5PX
060
F(A,B)4(A,B)N(F,B,C)
060
FB4(A,B)NB
070
FC4(B,C)N(F,B)
060
FC4(B,C)NB
070
FG3AAA
060
FK4(C,D)NB
006
FV4(A,B)NB
006
FX4(A,B)NB
060
COILS + 315(A,J)AV066110 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
CD5PX
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C).
** Total unit kW is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Capacity
Total
MBtuh†
MBtuh†
Sys
Total Sens‡
kW**
Total Sens‡
64.0
31.7
5.03
61.2
30.7
59.6
40.8
4.95
56.4
39.5
52.2
38.3
4.81
48.5
36.7
51.0
47.8
4.79
47.5
46.1
48.4
48.4
4.74
47.0
47.0
64.8
32.7
5.12
61.9
31.8
60.1
42.6
5.02
57.0
41.5
55.0
41.3
4.94
51.2
39.7
54.0
51.7
4.92
50.6
50.0
51.8
51.8
4.88
50.2
50.2
65.3
33.7
5.21
62.4
32.9
60.7
44.5
5.12
57.6
43.5
57.2
43.9
5.06
53.8
42.5
56.7
55.4
5.05
53.4
53.4
55.1
55.1
5.02
53.2
53.2
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.96
0.99
1.02
1.02
1.03
1.02
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.02
1.00
1.00
1.00
1.00
1.00
1.02
1.00
1.00
1.03
1.02
1.01
1.00
1.04
1.02
1.02
0.98
0.99
1.02
0.97
1.02
0.97
0.98
0.99
0.98
0.98
1.03
0.99
1.02
0.98
1.02
0.99
1.02
0.99
1.02
0.99
1.02
0.97
—32—
95
105
Capacity
Total
Total
MBtuh†
Sys
Sys
kW**
Total Sens‡
kW**
5.60
57.9
29.6
6.25
5.50
53.0
38.2
6.13
5.34
46.5
35.9
5.97
5.32
45.7
45.1
5.95
5.30
45.4
45.4
5.94
5.70
58.6
30.8
6.35
5.59
53.7
40.3
6.22
5.47
49.2
38.8
6.11
5.46
48.8
48.8
6.10
5.45
48.5
48.5
6.10
5.79
58.6
31.6
6.42
5.68
54.3
42.4
6.32
5.60
50.5
41.1
6.23
5.60
51.2
51.2
6.24
5.59
51.2
51.2
6.24
Indoor
Section
CK5PA
CK5PT
CK5PX
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CD5PX
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
115
Capacity
Capacity
Total
MBtuh†
MBtuh†
Sys
Total Sens‡
kW**
Total Sens‡
54.3
28.3
6.97
50.2
49.5
36.9
6.83
43.3
43.7
34.7
6.66
38.4
43.7
43.7
6.66
39.9
43.4
43.4
6.65
39.6
54.6
29.4
7.03
50.5
50.1
39.1
6.92
44.0
44.4
36.8
6.76
39.2
45.6
45.6
6.79
41.6
45.6
45.6
6.79
41.6
55.0
30.5
7.13
50.9
50.7
41.2
7.02
44.4
45.1
38.9
6.86
39.9
47.2
47.2
6.92
43.1
47.4
47.4
6.92
43.3
Cooling
Size
Capacity
060
1.02
060
1.02
060
1.02
060
0.98
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
0.98
060
060
1.03
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
125
Total
Sys
kW**
27.0
7.76
34.5
7.53
32.5
7.35
39.9
7.41
39.6
7.40
28.1
7.82
36.7
7.64
34.7
7.47
41.6
7.55
41.6
7.55
29.2
7.92
38.8
7.74
36.7
7.57
43.1
7.69
43.3
7.69
Power
0.99
0.99
0.97
0.98
0.99
0.98
0.99
0.99
0.99
0.97
0.99
0.99
0.97
0.97
1.00
0.98
0.97
0.98
0.98
0.98
0.97
0.98
0.98
0.97