Drawer Kick-Out Connector And Power Connector; Specifications Of Drawer Kick-Out Connector; Drawer Kick-Out Drive Signal; Electrical Characteristics - Citizen CBM-1000 User Manual

Line thermal printer
Hide thumbs Also See for CBM-1000:
Table of Contents

Advertisement

8. DRAWER KICK-OUT CONNECTOR AND POWER CONNECTOR

8.1 Specifications of Drawer Kick-Out Connector

8.1.1 Drawer Kick-Out drive signal

A pulse specified by ESC p is output. In parallel interface mode, the SW(+) state
can be confirmed at No. 34 pin of the interface connector or by the DLE EOT, GS a
and GS r commands at the serial/parallel interface.

8.1.2 Electrical characteristics

• Drive voltage: DC 24 V
• Drive current: 0.8 A maximum (Within 510 ms)
• SW signal:

8.1.3 Connector Pin Configuration

No.
1
2
3
4
5
6
CAUTION:
• No output is produced while printing.
• The drawers 1 and 2 cannot be driven simultaneously.
• A solenoid used for the drawer should be of 36
be kept at 0.8 A or less; otherwise, breakdown or burning could occur.
• This connector cannot be connected to a telephone line. Do not connect to anything
other than the solenoid.
Signal level "L" = 0 to 0.5 V
"H" = 3 to 5 V
Signal
FG
Frame Ground
DRAWER 1
Drawer 1 drive signal
DRSW
Drawer switch input
VDR
Drawer drive power supply
DRAWER 2
Drawer 2 drive signal
GND
Common ground on circuits
Connector used:
Applicable connector: TM3P-66P (Hirose) or equivalent
Function
TM5RJ3-66 (Hirose) or equivalent
or more. The output current should
— 37 —
6
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents