Page 2
Specifications: 1.Accuracy:Class Ⅲ 2. Sensitivity:1.5~3.0mV /V 3. Nonlinear:≤0.01%F.S 4. Working Voltage:DC:5V 5. Speed:10times/seconds(optional) 6. Internal Resolution:500000~1500000 Power Source 100~240V 50/60hz AC INPUT 12V/1A DC OUTPUT 6V/4AH Lead-acid rechargeable battery included Low battery warnings The display battery symbol lights up when battery voltage is lower than 5.6 V The display battery symbol starts to flash when battery voltage is lower than 5.5V The scale will shut off automatically when battery voltage is lower than 5.4V Preparation:...
Page 3
PIN 1: EXC+ PIN 2: EXC- PIN 3: SIG+ PIN 4: SIG- PIN 5: SHIELD Counting function specification If in unit setup mode,set the pieces,then activate counting function , operate specification as below: 1. Press 【UNITS】 key for two seconds, it shows “0” in the display. At the same time, the light of “PCS”...
Page 4
All other key will be disabled when gross weight is activated. ▲: To increase values upward in setup mode. PRINT: Manually transmitting data through RS232 to computer or printer at normal weighing mode(RS232 setup must be set at keyboard transmission 232 3 or 232 6 ) Functions keys of special kinds of scale(CWB22、CWT22): PT: Press PT key, enter in the weight of the container and then put the container on...
Page 5
3. Auto power-off In the weighing model, press and hold 【 tare】 key, and then press 【print】 key, it shows UF-1. Press 【tare】 key twice,it shows UF-3. Press【print】key,it shows A OFF 00, press 【 zero】 key to move cursor to left or press 【tare】 key to move cursor to right. Press【net/gross】key to add number, the number means the time of power off.
Page 6
8. G value In the weighing model, press and hold 【 tare】 key, and then press 【 print】 key, it shows UF-1. Press 【tare】 key for eight times,it shows UF-9. Press【print】key,it shows -00-,and then shows 9.79423(G value of the manufacturing place). And then press 【print】...
Need help?
Do you have a question about the TWT-01 and is the answer not in the manual?
Questions and answers