Test Procedure; Operation - SAFE-T-ALERT 65 Series User Manual

Surface / flush / recess mount models

Advertisement

automatically re-energize after the unsafe levels of CO clears.
Select a wall location at least 4" off the floor. 60-542-R Cut a 5 5/8"
(143mm) W x 3 1/8" (79mm) H hole. 60-541-R drill
for the wires.
Do not connect to a previously installed solenoid.
2.
SPECIAL WIRING NOTICE.
3. Connect Supply (+) to the Red wire lead. Install a 5 amp fuse in the
positive (+) circuit. Connect the Black wire to the 12 volt Ground (-).
4. Reconnect the power supply. Warm up 10 minutes then test the alarm.
MODEL 65-541-MS / 65-542-MS
1. Model 65-541/65-542-MS Multi-station interconnect, (Maximum 10
units and 2000 feet of wire). Allows multiple 65-541/542MS alarms to
be connected together. When one of the alarms detects unsafe levels of
CO or gas it will activate. It will also activate the audible alarm of all
the interconnected units. Only the alarm that detected CO or gas will
have its Red LED light lit up so that you can determine the cause of the
alarm. Select a wall location no between 4" and 20" off the floor. 60-
542-MS Cut a 5 5/8" (143mm) W x 3 1/8" (79mm) H hole. 60-541-MS
1/4" (6mm) hole
drill
for the wires.
2. Connect the Red wire to the 12 volt supply (+). Install a 1 amp fuse in
the positive circuit (+). Note you must use a separate 1 amp fuse for
each alarm. Connect the Black wire to the 12 volt Ground (-).
3. Interconnect Wiring – Connect Blue wires from each alarm and Yellow
wires for each alarm. Continue connecting in series (Daisy Chain).
4. Reconnect the power supply. Warm up 10 minutes then test the alarm.
MODEL 65-541-R-MS / 65-542-R-MS
1.
Model 65-541-R/65-542-R-MS - With Normally Closed relay. This
unit supplies a relay with contacts rated12 VDC, 3 amp (max). The
relay is energized whenever the alarm is operational. It may be used to
shut down a generator or to open an (optional) gas solenoid valve. The
relay may also be used to interface to alarm systems, using either the
normally closed or normally open contact, depending on the
requirements of the alarm system. In the event of an alarm the relay
will shut off. It will automatically re-energize after the unsafe levels of
CO clears.
Select a wall location at least 4" off the floor. 65-541-R-MS Cut a 5
5/8" (143mm) W x 3 1/8" (79mm) H hole.65-542-R-MS drill
(6mm) hole
for the wires.
Do not connect to an existing installed solenoid.
2.
SPECIAL WIRING NOTICE.
3.
Connect Supply (+) to the Red wire lead. Install a 5 amp fuse in the
positive (+) circuit. Connect the Black wire to the 12 volt Ground (-).
1/4" (6mm) hole
4.
Interconnect Wiring - Connect Blue wires from each alarm and Yellow
wires from each alarm. Continue connecting in series (Daisy Chain).
SEE:
5.
Reconnect the power supply. Warm up 10 minutes then test the alarm.
Model 65-541-R-MS / 65-542-R-MS Wiring -
Only use UL or recognized permanent wire connectors to
replace any unit installed with spade connectors or wire nuts.
TO REDUCE THE RISK OF CARBON MONOXIDE POISONING,
TEST THIS ALARM'S OPERATION AFTER THE RV HAS BEEN
IN STORAGE, BEFORE EACH TRIP AND AT LEAST ONCE PER
WEEK DURING USE BY PRESSING THE TEST/RESET BUTTON.
WARNING: THE TEST BUTTON ONLY TESTS THE
ALARM CIRCUIT NOT THE SENSORS. TO TEST THE CO
SENSOR USE A CAN OF SAFE-T-ALERT CO TEST GAS TO
TEST THE 400 PPM CALABRATION POINT. DO NOT TRY
TO GENERATE CO TO TEST THE ALARM.
button tests all ELECTRICAL functions of the alarm. It does not check the
sensor operation.
The alarm may be tested at any time. The TEST/Mute switch is located on
the front of the alarm. Press and hold the test button for 1 second
IMPORTANT
for repair or replacement. If the alarm is over five years old replace it.
SPECIAL WIRING NOTICE.
!
SAFE-T-ALERT alarm to non Safe-T-Alert supplied
solenoid. You must use a new solenoid with the correct
electrical rating.
When the unit is first powered up, the CO sensor requires a ten (10) minute
initial warm-up period to clean the sensor element and achieve stabilization.
The GREEN LED indicator will flash on and off during the 10 minute
warm-up period. This unit cannot go into a alarm during the warm-up
period. See Test Procedure in this manual. After the warm-up period, the
1/4"
GREEN power ON indicator should glow continuously If the ON indicator
light does not light, see the section, Trouble-Shooting Guide, in this
SEE:
manual for further information. Do not attempt to fix it yourself.

TEST PROCEDURE

!
WARNING
!
WARNING
- If this alarm does not test properly return it immediately
DANAGER - FIRE RISK - DO NOT CONNECT A

OPERATION