Connect to wiring or circuit that CANNOT be turned off by a
switch or ground fault protector. Only use UL or recognized
permanent wire connectors. It is acceptable to connect the 35
Series CO / LP gas alarm to the main disconnect. The alarm will be
off along with all other 12 volt equipment when the main disconnect
is turned to the off position. The RV must not be occupied when the
main disconnect is in the off position.
INSTALLATION INSTRUCTIONS
Follow these instructions carefully. Failure to follow these instructions can
damage the unit and void the warranty.
Select a wall location at least 4" but not more than 20" off the floor.
1. Disconnect the power supply being connected to.
2. This model requires a 1" clearance to recess the case. Cut a 5
3/8" W x 2" H hole
3. Connect the RED (+) power lead to the fused circuit. Connect
the BLACK lead to Ground (-).
4. Fasten the unit to the wall using the two screw holes located on
the ends of the case
5. Reconnect the power supply. Wait 10 minutes for warm up and
then test the alarm.
NOTE: All connections must be in accordance with the National
Electrical Code in the Unites Stated and the Canadian Electric Code in
Canada .

TEST PROCEDURE

!
TO REDUCE THE RISK OF CARBON MONOXIDE POISONING
OR PROPANE GAS EXPLOSION,
OPERATION AFTER THE RV HAS BEEN IN STORAGE, BEFORE
EACH TRIP AND AT LEAST ONCE PER WEEK DURING USE.
!
WARNING: THE TEST BUTTON ONLY TESTS THE
ALARM CIRCUIT NOT THE SENSORS. YOU MAY USE
PROPANE OR BUTANE GAS TO TEST THE GAS SENSOR.
Note it may take up to 10 seconds for the alarm to sound.
TO TEST THE CO SENSOR USE A CAN OF SAFE-T-ALERT
CO TEST GAS TO TEST THE 400 PPM CALABRATION
POINT. DO NOT TRY TO GENERATE CO TO TEST THE
ALARM.
The TEST/RESET button tests all ELECTRICAL functions of
the alarm. It does not check the sensor operation.
The alarm may be tested at any time -The TEST/Mute switch is located on
the front of the alarm Press and hold the test button for 1 second. The alarm
is working properly if the GREEN indicator light changes color to RED and
the horn beeps 4 times. The Gas LED should also blink Red.
IMPORTANT
- If this alarm does not test properly return it immediately
for repair or replacement.

OPERATION

Each time the unit is first powered up, the CO sensor requires a ten (10)
minute initial warm-up period to clean the sensor element and achieve
stabilization. The GREEN LED indicator will flash on and off during the 10
minute warm-up period. This unit cannot go into a CO alarm during the
warm-up period. To test your unit during the warm-up period, press the test
button. See Test Procedure in this manual. After the warm-up period, the
GREEN power ON indicator should glow continuously If the ON indicator
light does not light, see the section, Trouble-Shooting Guide, in this
manual for further information. Do not attempt to fix it yourself.
WARNING
TEST
THIS
ALARM'S
WARNING
Gas Alarm: When you power the alarm, it has a warm-up period of
approximately 1 minute. This unit cannot go into a gas alarm during the
warm-up period. After 1 minute the alarm can detect explosive gas.
Simultaneous CO and Gas Alarms— Because the risk of a propane gas
explosion is generally a more serious danger, your alarm unit gives the gas
alarm a higher priority during simultaneous alarm condition.
If your unit generates alarms for both Gas and CO at the same time, the gas
LED will flash red and the beeper will sound. The CO LED will be a solid
Red until the CO is ventilated out of the RV, at which time the LED will
return to the Green operational/safe color.
Brownout Protection - The unit can tolerate short power interruptions and
brownouts where the circuit voltage drops as low as 1VDC. If the brownout
lasts too long, the unit will reset and operate as described above.
LOW POWER OPERATION
This alarm will operate normally down to7 VDC. Do not operate this alarm
below 7 VDC.
VISUAL AND AUDIBLE ALARM SIGNALS
TM
This SAFE-T-ALERT
CO / Propane Gas Alarm is designed to be easy-
to-operate. The alarm has two indicator lights that display a specific color
for each monitored condition. There also is a matching sound pattern for
alarm conditions.
CO ALARM
The Red CO LED will flash and the alarm will sound 4 "BEEPS" then
silent for 5 Seconds. These signals indicates that the CO level is over 35
ppm. IMMEDIATE ACTION IS REQUIRED. See Procedures To Take
During An Alarm. This cycle will continue until the TEST/Mute button on
the front of alarm is pressed. Ventilate the RV. The RED light will stay ON
until the CO has cleared, or the alarm will reactivate in approximately 6
minutes if the CO is still present. DO NOT RE-ENTER THE RV. This
alarm will return to normal operation after the RV s properly ventilated.
PROPANE GAS ALARM
The Red LED will Flash and the alarm will sound a steady tone whenever a
dangerous level of propane or methane gas is detected. IMMEDIATE
ACTION IS REQUIRED. See Procedures Take During A Gas Alarm
The detector will continue to alarm until the Test/Mute switch on the front
of the alarm is pressed. Ventilate the RV. The RED Gas LED will continue
to flash until the gas has cleared, or the gas alarm will reactivate in
approximately 5 minutes if the gas is still present. DO NOT RE-ENTER
THE RV. This alarm will return to normal operation after the RV s properly
ventilated.
MALFUNCTION/SERVICE SIGNAL If any malfunction is detected, the
Gas LED will remain off and the Operational/CO LED will alternate
Red/Green and the alarm will sound once every 15 seconds. Press the
Test/Mute button. If the Test/Mute button does not clear the signals, check
the battery voltage. If the battery voltage is not low and the unit will not
return to normal operation, immediately remove the alarm and return
for service or warranty replacement. See the warranty section in this
manual.
OPERATION
AUDIBLE SIGNAL
NORMAL
NONE
CO ALARM
4 "BEEPS"
5 SECONDS OFF
PROPANE ALARM
CONSTANT
ALARM
"
BEEP" EVERY
MALFUNCTION
30 SECONDS
END OF LIFE
B BEEPS EVERY
25-30 SECONDS
VISUAL SIGNAL
STEADY GREEN
STEADY RED
FLASHING RED
ALTERNATING
RED/GREEN