To protect yourself, family and guests, you should:
INSTALL THE ALARM PROPERLY. Carefully read and follow
ALL the instructions in this manual. Test your unit every week. Alarms
that do not work will not alert you to hazardous levels of CO and need to
be replaced.. See the section, Test Procedure, in this manual for further
information.
 MAKE REGULAR VISUAL INSPECTIONS. Check all fuel burning
equipment including gas water-heaters, kitchen gas stoves, space heaters,
gas dryers and all pilot lights. Check the color of the pilot flame. The
color should be blue.
MAKE REGULAR VISUAL INSPECTIONS OF THE ENGINE
AND GENERATOR EXHAUST SYSTEMS. Cracked exhaust systems
can allow CO to enter the living area.
 PROFESSIONALLY
MAINTAIN
GENERATOR. Although gas engines and generators produce CO, a
poorly tuned engine and generator will produce greater amounts CO.

WHERE TO INSTALL

MTI recommends installing a gas alarm in each sleeping area.
The
NFPA
and
Consumer
recommends installing a CO alarm outside the sleeping area. The
65 Series CO alarm complies with that recommendation.
INSTALL ALARM at least 4 inches off the floor.
WHERE NOT TO INSTALL 65 SERIES ALARMS
DO NOT INSTALL behind furniture, drapes, in closets or areas that
will block air flow to the alarm.
DO NOT INSTALL within 12 inches (30cm) of opening windows,
exterior doors, heating or return vents, or other drafty areas..
DO NOT INSTALL on an outside wall.
DO NOT INSTALL on a wall switch controlled by a power line,
ground fault circuit or to a circuit breaker.
NOTE: Older RVs may have little or no insulation and therefore are
draftier. Carefully consider mounting locations. The following diagrams
provide additional alarm installation information:
Bath
Kitchen
Bedroom
CO DETECTOR LOCATION
FOR MINIMUM SECURITY
Do not install within 12" of
a windo w that can op en
Do not inst all
within 12" of vents
FIGURE 2
YOUR
ENGINE
Product
Safety
Commission
FIGURE 1
CO DETECTOR LOCATION
FOR ADDITIONAL SECURITY
Do not install within
12" of a door
Do Not install b ehind drapes
or furniture

INSTALLATION INSTRUCTIONS

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT
IN A MALFUNCTION OR FAILURE OF THE ALARM AND MAY
VOID THE WARRANTY.
SHOCK HAZARD: Turn off power before installing.
Power Supply 12 VDC.
Recommended Wire Size 14 GA. TO 18 GA.
AND
Connect the alarm to a properly fused circuit, maximum over
protection device rating 6 amps.
All connections must be in accordance with the National
Electrical Code in the Unites Stated and the Canadian Electric
Code in Canada .
Connect to wiring or circuit that CANNOT be turned off by a
switch or ground fault protector. Only use UL or recognized
permanent wire connectors. It is acceptable to connect the 65
Series CO alarm to the main disconnect. The alarm will be off
along with all other 12 volt equipment when the main disconnect is
turned to the off position. The RV must not be occupied when the
main disconnect is in the off position.
INSTALLATION INSTRUCTIONS
Follow these instructions carefully. Failure to follow these instructions can
damage the unit and void the warranty.
Important: The 65 Series Flush / Recess mount case requires 1 1/2"
(38mm) clearance behind the wall.
MODEL 65-541 / 65-542
1. Basic Model 65-541/65-542 - Select a wall location at least 4" off the
floor. Cut a 5 5/8" (143mm) W x 3 1/8" (79mm) H hole. For the 60-541
1/4" (6mm) hole
Drill a
2. Connect Supply (+) to the Red wire lead. Install a 1 amp fuse in the
positive (+) circuit. Connect the Black wire to the 12 volt Ground (-).
3. Reconnect the power supply. Warm up 10 minutes then test the alarm.
MODEL 65-541-R / 65-542-R (Relay Control)
1.
Model 65-541-R/65-542-R - With Normally Closed relay. This unit
supplies a relay with contacts rated 12 VDC, 3 amp (max). The relay is
energized whenever the alarm is operational. It may be used to shut down
a generator or to open an (optional) gas solenoid valve. The relay may
also be used to interface to alarm systems, using either the normally
closed or normally open contact, depending on the requirements of the
alarm system. In the event of an alarm the relay will shut off. It will
Models
!
WARNING
for the wires.