§1. Introduction
Wireless Communication Frequency
Wireless Communication Distance
Wireless Communication Rate
Serial Interface
Connect by RS232
Decimal System/Hexadecimal System
External AC Adapter
Rechargeable Internal Battery
Operating Temperature
Storage Temperature
Relative Humidity
§2. Wireless Connection
Note: One wireless indicator only can connect with one wireless weighing transmitter, and both
wireless communication frequencies should be same. Wireless communication frequencies are set in
factory and user cannot change. Regular wireless communication frequency is 430MHz
If user wants to use two or more than two set of wireless weighing indicator and wireless weighing
transmitter, wireless communication frequencies must be different. Please let salesman know and
wireless communication frequencies will be set in factory.
1.
Connect wireless weighing transmitter with load cell.
2.
Switch on wireless weighing transmitter until the wireless function works.
3.
Switch on wireless weighing indicator and calibrate.
4.
In configuration mode, set "Con" to Con=78.
5.
When indicator wireless lamp flashes, wireless weighing transmitter and wireless weighing indicator
are connecting.
6.
Then, to calibrate wireless weighing indicator and configure.
7.
RS-232C D-B 9: Pin 3 Output (TXD) and Pin 5 Signal Ground (GND)
8. RS232 interface is continuous data output
9.
Address = 0 continuous data output, form is =,X1,X2,X3,X4,X5,X6, while X1,X2,X3,X4,X5,X6 is
data,= is break. E.g.: if weigh is 123.45kg, data will be = 54.321 =54.321
Address = 99 continuous data output, form is =,X6,X5,X4,X3,X2,X1, while X6,X5,X4,X3,X2,X1 is
data,= is break. E.g.: if weigh 123.45kg, data will be = 123.45= 123.45
430 MHz
30M/1500M (optional)
9600bps
X1FM: 6-digit 0.8 inches red LED
Display
X5FM: 6-digit 0.8 inches green LED
1/2/5/10/20/50/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005
Division
RS232 interface with continuous data output
Baud rate 1200, 2400, 4800, 9600
Optional RS485 interface
Display, computer, printer, etc.
kg/lb/UU (user unit should be set in factory)
Weight Unit
lb and UU can be in two systems
100-240VAC 50/60Hz
6V/4AH
–10 °C to +40 °C
–25 °C to +55 °C
10% to 85% non-condensing
X1FM: 220×140×130 (mm)
Dimensions
X5FM: 265×162×58 (mm)
2kg
Weight
VER 22.0
Version