§1. Introduction 430 MHz Wireless Communication Frequency 30M/1500M (optional) Wireless Communication Distance 9600bps Wireless Communication Rate X1FM: 6-digit 0.8 inches red LED Display X5FM: 6-digit 0.8 inches green LED 1/2/5/10/20/50/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005 Division RS232 interface with continuous data output Serial Interface Baud rate 1200, 2400, 4800, 9600 Optional RS485 interface Display, computer, printer, etc.
Page 4
§3. Keypad Function and Status Indicators ON : Switch on OFF : Switch off : Manual accumulation mode * : Select function and configure → : Move flashing digit ↑ : Increase flashing digit and high resolution →0← : Zero, tare and decrease flashing digit AC : Mains power applied : Battery capacity AUT : Automatic accumulation mode...
Page 5
switch off function disable Ones digit=1 means zero when weight is 2℅F·S, and automatic switch off function enable Ones digit=2 means zero when weight is 20℅F·S, and automatic switch off function disable Ones digit=3 means zero when weight is 20℅F·S, and automatic switch off function enable Ones digit=4 means zero when weight is 50℅F·S, and automatic...
Step Operation Displaying Descriptions Press CAL SP Indicator in calibration mode Press → CAL 00 Enter to set ZERO Press ------ Set ZERO 3000 After several seconds, indicator displays maximum weight Load max weight 3000 Display weight Press Press → 000000 If the weight is not the max weight, press →...
Hexadecimal displays automatically retain two decimal points. 2 After The Decimal Point Every 16 Binary Press → Digit flash Press ↑ Change digit →0← Press d 0. 0.0 Set display form when unit is lb or UU HE=1, d has two situations: 0. 0.0 and 0. 0 Press ↑...
Page 8
Aut=3: animal weighing mode, accumulate automatically finial weight which is unload 20d, -AUT- turns on Aut=4: peak hold mode, accumulate automatically finial weight which is unload 20d, -AUT- turns on Aut=5: animal weighing mode and manual accumulation Aut=6: peak hold mode and manual accumulation Aut=7: counting mode and manual accumulation Aut=8: double-way weighing mode, weight pressure and pull from positive and negative way...
Page 9
press → Cnt030 Enter sample amount 30 press ↑ →0← press Save samples data and display samples amount press ↑ Press ↑ to change weighing and amount displaying Operation put the weight on scale, number is weight when indicator displays 54 , and number is amount when indicator displays 60 .
N: 2.91kg C: 54pcs Accumulation mode NO: 0002 S: 5.82kg Accumulation with counting mode: NO: 0002 C: 108pcs S: 5.82kg §15. Safety precautions Do not expose indicators to either direct sun light or any heat sources. Do not use indicators in hazardous area or in dusty environments. Weight cannot more than max weighing Do not use strong solvents (such as: benzene, nitric acid oil) to clean the indicators.
Need help?
Do you have a question about the X1FM and is the answer not in the manual?