KX-TG8200BXB/KX-TGA820BXB 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
KX-TG8200BXB/KX-TGA820BXB 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TG8200BXB/KX-TGA820BXB 3 Specifications Note: • Specifications are subject to change. Note for Service: • Operation range: Up to 300 m outdoors, Up to 50 m indoors, depending on the condition. • Analog telephone connection: Telephone Line...
KX-TG8200BXB/KX-TGA820BXB 4.2. Circuit Operation (Base Unit) 4.2.1. Outline Base Unit consists of the following ICs as shown in Block Diagram (Base Unit) (P.7). • DECT BBIC (Base Band IC): IC7 - Handling all the audio, signal and data processing needed in a DECT base unit...
Page 9
KX-TG8200BXB/KX-TGA820BXB 4.2.2. Power Supply Circuit The power is supplied to the DECT BBIC, RF Module, EEPROM and Charge Contact from AC Adaptor (+6.5 V) as shown in Fig.101. The power supply is as follows; • DECT BBIC (IC7): CN2 (+6.5 V) → IC1 → Q9 → IC7 CN2 (+6.5 V) →...
Page 10
KX-TG8200BXB/KX-TGA820BXB 4.2.3. Telephone Line Interface <Function> • Bell signal detection • Clip signal detection • ON/OFF hook circuit Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection: In the standby mode, Q3 is open to cut the DC loop current and decrease the ring load.
KX-TG8200BXB/KX-TGA820BXB 4.4. Circuit Operation (Handset) 4.4.1. Outline Handset consists of the following ICs as shown in Block Diagram (Handset) (P.11). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD) •...
KX-TG8200BXB/KX-TGA820BXB 5 Location of Controls and 6 Installation Instructions Components 6.1. Connections 5.1. Controls 5.1.1. Base Unit 5.1.2. Handset...
6.2.3. Battery Level 6.2.4. Panasonic Ni-MH Battery Performance (supplied batteries) Note: • It is normal for batteries not to reach full capacity at the initial charge. Maximum battery performance is reached after a few complete cycles of charge/discharge (use).
KX-TG8200BXB/KX-TGA820BXB 7 Operation Instructions 7.1. Base Unit Settings *1 The item will not be reset when pressing key of the handset. Refer to How to Clear User Setting (P.30). *2 Change the recall time, if necessary, depending on the requirements of your service provider/telephone company or PBX.
KX-TG8200BXB/KX-TGA820BXB 7.2. Handset Settings *1 The item will not be reset when pressing keys. Refer to How to Clear User Setting (P.30). *2 The item will not be reset when pressing keys. Refer to How to Clear User Setting (P.30).
KX-TG8200BXB/KX-TGA820BXB 7.3. Registering a Handset to a Base Unit If you forget your PIN, see For Service Hint (P.23). 7.3.1. Deregistering a handset 7.3.2. Cancelling a base unit Cross Reference: Registering a Handset to a Base Unit (P.19)
KX-TG8200BXB/KX-TGA820BXB 7.4. Copying Phonebook Entries You can copy handset phonebook entries to the handset phonebook of another compatible Panasonic handset. Note: • Category settings for phonebook entries are not copied 7.4.1. Copying all entries 7.5. Dialling Mode (Tone/Pulse) 7.6. Error Message...
KX-TG8200BXB/KX-TGA820BXB 7.7. Troubleshooting If you still have difficulties after following the instructions in this section, disconnect the base unit AC adaptor and turn off the handset, then reconnect the base unit AC adaptor and turn on the handset.
Page 22
KX-TG8200BXB/KX-TGA820BXB Cross Reference: For Service Hint (P.23)
KX-TG8200BXB/KX-TGA820BXB 8 Service Mode 8.1. Engineering Mode 8.1.1. Base Unit...
Page 25
KX-TG8200BXB/KX-TGA820BXB Frequently Used Items (Base Unit) ex.) Items Address Default Data New Data Remarks C-ID (FSK) sensitivity 04 C3 01 (6 dB up) 02 (12 dB up) When hex changes from “00” to “01” or “02”, gain increases by 6 dB or 12 dB.
Page 27
KX-TG8200BXB/KX-TGA820BXB Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Sending level 00 06 Adjusted value Given value (*2) Receiving level 00 07 Adjusted value Given value...
KX-TG8200BXB/KX-TGA820BXB 8.2. Copying Phonebook Items when Repairing You can copy the handset phonebook to another (compatible Panasonic) handset. This will help to save the original phonebook data which the customer has registered. Available models: KX-TG8200 Refer to the following procedures.
Page 29
KX-TG8200BXB/KX-TGA820BXB Note: • BS=Base Unit , HS=Handset • If the max number of handsets are already registered to the base unit, a new handset cannot be registered. • To register the handset, refer to Registering a Handset to a Base Unit (P.19) •...
KX-TG8200BXB/KX-TGA820BXB 8.3. How to Clear User Setting Units are reset to the Factory settings by this operation (Erase stored Phone numbers, Caller list and etc.) Note: • Some menus are not reset. Refer to Operation Instructions (P.17). • The reset menus differ depending on the following operations.
KX-TG8200BXB/KX-TGA820BXB 9 Troubleshooting Guide 9.1. Troubleshooting Flowchart Flow Chart Cross Reference: Check Power (P.32) Bell Reception (P.42) Check Battery Charge (P.33) Check Link (P.34) Check the RF part (P.38) Check Handset Transmission (P.41) Check Handset Reception (P.41) Signal Route (P.14)
Page 32
KX-TG8200BXB/KX-TGA820BXB 9.1.1. Check Power 9.1.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (*1) Cross Reference: Note: Power Supply Circuit (P.9) (*1) Refer to Specifications (P.6) for part number and supply voltage of AC Adaptor. 9.1.1.2. Handset Cross Reference:...
Page 33
KX-TG8200BXB/KX-TGA820BXB 9.1.2. Check Battery Charge 9.1.2.1. Base Unit Cross Reference: Charge Circuit (P.12) 9.1.2.2. Handset Cross Reference: Check Power (P.32) Charge Circuit (P.12) 9.1.2.3. Charger Unit Cross Reference: Charge Circuit (P.12)
Page 34
KX-TG8200BXB/KX-TGA820BXB 9.1.3. Check Link 9.1.3.1. Base Unit Note: (*1) Refer to Troubleshooting by Symptom (Base Unit and Charger Unit) (P.43) Cross Reference: Check Point (Base Unit) (P.43) Power Supply Circuit (P.9)
Page 35
KX-TG8200BXB/KX-TGA820BXB Cross Reference: Check Point (Base Unit) (P.43)
Page 36
KX-TG8200BXB/KX-TGA820BXB 9.1.3.2. Handset Cross Reference: Check Point (Handset) (P.46) Power Supply Circuit/Reset Circuit (P.12)
Page 37
KX-TG8200BXB/KX-TGA820BXB Cross Reference: Check Point (Handset) (P.46)
Page 38
KX-TG8200BXB/KX-TGA820BXB 9.1.4. Check the RF part 9.1.4.1. Finding out the Defective part After All the Checkings or Repairing 1. Re-register the checked Handset to the checked Base Unit, and Regular HS to Regular BU. Note: If you need to register a handset, refer to Registering a Handset to a Base Unit (P.19)
Page 39
KX-TG8200BXB/KX-TGA820BXB 9.1.4.2. RF Check Flowchart Each item (1 ~ 4) of RF Check Flowchart corresponds to Check Table for RF part (P.40). Please refer to the each item. Note: (*1) Base unit - refer to (F) of Check Point (Base Unit) (P.43)
Page 40
KX-TG8200BXB/KX-TGA820BXB 9.1.4.3. Check Table for RF part Item BU (Base Unit) Check HS (Handset) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). (*1) BU. (*1) 2. Press [Talk] key of the Regular HS to 2.
Page 41
KX-TG8200BXB/KX-TGA820BXB 9.1.5. Check Handset Transmission Cross Reference: Signal Route (P.14) 9.1.6. Check Handset Reception Cross Reference: How to Check the Handset Speaker or Receiver (P.68). Signal Route (P.14) 9.1.7. Check Caller ID Cross Reference: Signal Route (P.14)
Page 42
KX-TG8200BXB/KX-TGA820BXB 9.1.8. Bell Reception 9.1.8.1. Base Unit 9.1.8.2. Handset Cross Reference: Telephone Line Interface (P.10) Check Link (P.34) How to Check the Handset Speaker or Receiver (P.68)
KX-TG8200BXB/KX-TGA820BXB 9.2. Troubleshooting by Symptom (Base Unit and Charger Unit) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail.
Page 44
KX-TG8200BXB/KX-TGA820BXB Items Check Procedure Check or Point Replace Parts (G)* Hookswitch Check with 1. Connect CN1 (Telephone Socket) to Tel-simulator which is connected with L1, L2, Q3, R14, 600 Ω. DC Characteristics R15, Q4, R16, 2. Set line voltage to 48 V and line current to 40 mA at off-hook condition of nor- R17, IC7, D3 mal telephone.
Page 45
KX-TG8200BXB/KX-TGA820BXB Items Check Procedure Check or Point Replace Parts (O)* Power RAMP Confirma- Follow steps 1 to 6 of (I). IC7, IC10, L7, tion 7.Confirm that Power RAMP is matching. C117, C118, C124, C125, R106, R109, DA1, C112, R111, C126,...
KX-TG8200BXB/KX-TGA820BXB 9.3. Troubleshooting by Symptom (Handset) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail.
Page 47
KX-TG8200BXB/KX-TGA820BXB Items Check Procedure Check or Point Replace Parts (H)* Battery Monitor Check 1. Apply 2.25 V between BATT and GND. IC1, F1, C1 2. Execute the command “readbatt”. C3, R12 It assumes that the return value is XX. a) 1E...
Page 48
KX-TG8200BXB/KX-TGA820BXB Items Check Procedure Check or Point Replace Parts (P)* Power RAMP Confirma- Follow steps 1 to 3 of (K). IC1, IC4, C58, tion 4.Confirm that Power RAMP is matching. C57, C52, C53, R52, C61, C59, C125, C62 (Q) Audio Check and Confir- 1.
KX-TG8200BXB/KX-TGA820BXB 9.4. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
Page 50
KX-TG8200BXB/KX-TGA820BXB 9.4.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TG8200BXB/KX-TGA820BXB 9.5. How to Replace the LLP (Leadless Leadframe Package) IC 9.5.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 52
KX-TG8200BXB/KX-TGA820BXB 9.5.4. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. 2. Place the solder a little on the land where IC pins are to be attached, then place the IC.
KX-TG8200BXB/KX-TGA820BXB 11 Measurements and Adjustments 11.1. The Setting Method of JIG (Base Unit) 11.1.1. Preparation 11.1.1.1. Equipment Required • DECT tester: Rohde & Schwarz, CMD 60 is recommended. • Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Page 59
KX-TG8200BXB/KX-TGA820BXB 11.1.2.2. Batch file Setting Note: • “****” varies depending on the country. 11.1.2.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG8200BXB/KX-TGA820BXB 11.3. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 11.3.1. Flow Solder Side View Digital Volt Mater /2 W DC POWER DC 6.5 V Note: (A) is referred to Check Point (Charger Unit) (P.45)
KX-TG8200BXB/KX-TGA820BXB 11.4. The Setting Method of JIG (Handset) 11.4.1. Preparation 11.4.1.1. Equipment Required • DECT tester: Rohde & Schwarz, CMD 60 is recommended. • Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Page 63
KX-TG8200BXB/KX-TGA820BXB 11.4.2.2. Batch file Setting Note: • “*****” varies depending on the country. 11.4.2.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG8200BXB/KX-TGA820BXB 11.6. Things to Do after Replacing IC or X'tal Cautions: Some of the content on this page may not apply to models from some countries. The contents below are the minimum adjust- ments required for operation. 11.6.1. Base Unit Before making the following adjustment, ensure you have carried out PC Setting (P.58) in The Setting Method of JIG (Base...
Page 66
KX-TG8200BXB/KX-TGA820BXB 11.6.2. Handset Before making the following adjustment, ensure you have carried out PC Setting (P.62) in The Setting Method of JIG (Hand- set). Items Necessary Adjustment BBIC (FLASH type) Programs for Voice processing, interface for RF 1. Make sure to connect the JIG cable, then detach the DC...
KX-TG8200BXB/KX-TGA820BXB 11.8. How to Check the Handset Speaker or Receiver 1. Prepare the digital voltmeter, and set the selector knob to ohm meter. 2. Put the probes at the speaker terminals as shown below. 11.9. Frequency Table (MHz) BASE UNIT...
KX-TG8200BXB/KX-TGA820BXB 12 Schematic Diagram 12.1. For Schematic Diagram 12.1.1. Base Unit (Schematic Diagram (Base Unit)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology.
Page 71
KX-TG8200BXB/KX-TGA820BXB LINE_DC Loop Current 100k *R13 *R17 2.2k 180k 1.5n C136 for BR Caller ID, 180k Bell Signal 1.5n C137 RX_AF for BR 5.6M TX_AF +2.5V 100k for NL 100k TP_RLY1 L1T/TP_RLY2 for JT 220p 220p L2T/TP_RLY3 L1R/TP_RLY4 5.6M Bell signal...
(*1) This cable is fixed by soldering. Refer to Fix the LCD to the Main P.C. Board (Handset) (P.57). (*2) The rechargeable Ni-MH battery P03P (HHR-4EPT, Capacity: up to 750 mAh) is available through sales route of Panasonic. (*3) Attach the spacer (No. 125) to the exact location described above.
KX-TG8200BXB/KX-TGA820BXB 15.5. Replacement Part List Ref. Part No. Part Name & Description Remarks 1. RTL (Retention Time Limited) PQGT19921Z NAME PLATE Note: 15.5.1.2. Main P.C.Board Parts The “RTL” marking indicates that its Retention Time is Note: Limited. (*1) When replacing IC5, IC7 or X1, data needs to be writ- When production is discontinued, this item will con- ten to them with PQZZTG8200BX.
Page 91
KX-TG8200BXB/KX-TGA820BXB Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks ERJ2GEJ104 100K ECUE1A104KBQ ERJ2RKF1200 ECUE1A104KBQ ERJ2RKF2000 ECUE1H102KBQ 0.001 ERJ1TYJ3R9U C103 ECUE1H100DCQ ERJ1TYJ3R9U C106 ECUE1H100DCQ ERJ1TYJ3R3U C108 PQCUV0J475MB ERJ2GEJ222 2.2K C110 ECUE1H100DCQ ERJ2GEJ222 2.2K...
Page 92
KX-TG8200BXB/KX-TGA820BXB X'tal. Ref. Part No. Part Name & Description Remarks ERJ2GEJ101 Ref. Part No. Part Name & Description Remarks ERJ2GEJ103 ERJ2GEJ103 PCB100 PQWPGA820BXR MAIN P.C.BOARD ASS'Y (RTL) ERJ2GEJ102 (ICs) ERJ3GEYJ470 C1CB00001831 IC (BBIC(FLASH)) (*1) (*2) R103 ERJ2GEJ101 PQWIA130EXRR IC (EEPROM) (*1)
Page 93
ERG2SJ100E (FUSE) K5H302Y00003 FUSE 15.5.4. Accessories and Packing Materials Note: (*1) You can download and refer to the Operating Instruc- tions (Instruction book) on TSN Server. 15.5.4.1. KX-TG8200BXB Ref. Part No. Part Name & Description Remarks PQLV207BXZ AC ADAPTOR PQJA10075Z...