Panasonic I-PRO EXTREME Series Manual page 19

Snmp mib
Table of Contents

Advertisement

SNMP MIB manual for i-PRO camera
pwType
objectName
object id
SYNTAX RANGE INTEGER { ok(1), Disabled(2), warning(3), Failed(4) }
DESCRIPTION
▪ Recommended monitoring method
-
WV-X6533L, WV-S6532L, WV-X6531N, WV-X6511N, WV-SUD638
Connect to the correct power supply and check if there is any change during
operation from the response string obtained first.
-
Fixed cameras, fisheye cameras, cameras other than those listed above
Even if the power is disconnected, there is no functional limitation as long as PoE
is connected.
If you want to check for unintended power supply replacement, perform regular
monitoring.
▪ When an error notification is received from the network monitoring system
-
WV-X6533L, WV-S6532L, WV-X6531N, WV-X6511N, WV-SUD638
The power cable is disconnected. The temperature control function such as fan or
heater may be disabled. Make sure that the camera is connected to the correct
power.
-
Fixed cameras, fisheye cameras, cameras other than those listed above
The power supply type has been changed during operation. Check if this change is
intended
Panasonic i-PRO Sensing Solutions Co., Ltd.
pwType
.1.3.6.1.4.1.258.5100.100.1.2.6
The type of power supply currently in use.