SNMP MIB manual for i-PRO camera
pwType
objectName
object id
SYNTAX RANGE INTEGER { ok(1), Disabled(2), warning(3), Failed(4) }
DESCRIPTION
▪ Recommended monitoring method
-
WV-X6533L, WV-S6532L, WV-X6531N, WV-X6511N, WV-SUD638
Connect to the correct power supply and check if there is any change during
○
operation from the response string obtained first.
-
Fixed cameras, fisheye cameras, cameras other than those listed above
Even if the power is disconnected, there is no functional limitation as long as PoE
○
is connected.
If you want to check for unintended power supply replacement, perform regular
○
monitoring.
▪ When an error notification is received from the network monitoring system
-
WV-X6533L, WV-S6532L, WV-X6531N, WV-X6511N, WV-SUD638
The power cable is disconnected. The temperature control function such as fan or
○
heater may be disabled. Make sure that the camera is connected to the correct
power.
-
Fixed cameras, fisheye cameras, cameras other than those listed above
The power supply type has been changed during operation. Check if this change is
○
intended
Panasonic i-PRO Sensing Solutions Co., Ltd.
pwType
.1.3.6.1.4.1.258.5100.100.1.2.6
The type of power supply currently in use.