Summary of Contents for Panasonic I-PRO EXTREME Series

  • Page 1 SNMP MIB manual for i-PRO camera SNMP MIB manual for i-PRO camera Ver. 3 Panasonic i-PRO Sensing Solutions Co., Ltd. Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 2 SNMP MIB manual for i-PRO camera Change history Version Date Chapter # Comment Trigger 6/10/2020 Added MIB explanation for Trap Trap function added 10/18/2019 First release Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 3 This document is copyright protected and Panasonic i-PRO Sensing Solutions Co., Ltd. reserves all titles and rights in the document. Nobody can copy, reproduce, distribute, or modify this document in any way without the prior written consent of Panasonic i-PRO Sensing Solutions Co., Ltd..
  • Page 4: Table Of Contents

    2. Overview of SNMP support for i-PRO cameras ............8 SNMP version ....................9 PDU-type ......................9 3. MIBs supported by i-PRO cameras ................. 10 Standard MIB ....................11 Extended MIB of Panasonic Corporation ............12 PANASONIC-MIB ..................12 PANA-NCE-SEC ..................13 PANA-SECURITY-MIB ................15 PANA-CAM-MIB ..................15 PANA-CAMTRAP-MIB ................
  • Page 5: Introduction

    This document describes the setting information necessary for the network monitoring system to monitor the camera using the SNMP protocol, and tips for the network administrator to perform camera maintenance. This document does not provide detailed descriptions of SNMP specifications or standard MIBs. Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 6: Definition

    Panasonic Company name. (Corporation) PANASONIC(- Name of the MIB that defines the object ID that Panasonic Corporation MIB) applied for in the extended MIB Object name defined in the PANASONIC-MIB. Panasonic Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 7: Target Devices

    SNMP MIB manual for i-PRO camera Target devices The devices mentioned in this document are i-PRO EXTREME series and WV-SUD638. This document describes the features in the latest firmware version. The differences in functions for each model will be explained in the next chapter.
  • Page 8: Overview Of Snmp Support For I-Pro Cameras

    Not supported Not supported The following models do not support Trap : WV-U1113, WV-U1114, WV-U1130, WV- U1132, WV-U1133, WV-U1134, WV-U1142, WV-U1532L, WV-U1533, WV-U1542L, WV- U2114, WV-U2130L, WV-U2132L, WV-U2134, WV-U2140L, WV-U2142L, WV-U2530L, WV- U2532L, WV-U2540L, WV-U2542L Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 9: Snmp Version

    SNMP MIB manual for i-PRO camera SNMP version i-PRO EXTREME series supports v1, v2c, v3 GET. It also supports v2c Trap.  WV-SUD638 and WV-SUD638B support GET of v1 and v2c.  PDU-type The PDU-Types supported by i-PRO cameras are shown below.
  • Page 10: Mibs Supported By I-Pro Cameras

    SNMP MIB manual for i-PRO camera 3. MIBs supported by i-PRO cameras The i-PRO camera responds with standard MIB (mainly mib-2) and extended MIB (panasonic). This chapter describes the response contents of the standard MIB supported by the camera and the OID of the extended MIB.
  • Page 11: Standard Mib

    OID responses defined by the following standard MIBs at maximum. SNMPv2-MIB IF-MIB IP-MIB TCP-MIB UDP-MIB RFC1213-MIB IPV6-MIB IF-MIB SNMPv2-MIB SNMP-FRAMEWORK-MIB SNMP-MPD-MIB SNMP-USER-BASED-SM-MIB SNMP-VIEW-BASED-ACM-MIB The i-PRO camera does not support the following MIBs when requested with v1 and v2c. SNMP-FRAMEWORK-MIB SNMP-MPD-MIB SNMP-USER-BASED-SM-MIB SNMP-VIEW-BASED-ACM-MIB Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 12: Extended Mib Of Panasonic Corporation

    PANASONIC-MIB PANASONIC-MIB is OID 258 for Panasonic Corporation that has been applied to IANA, Defines .iso (1) .org (3) .dod (6) .internet (1) .private (4) .enterprises (1) .panasonic (258). SNMPv2-SMI and SNMPv2-TC are required to interpret this MIB. There is no definition of OID that the camera can respond to in this MIB.
  • Page 13: Pana-Nce-Sec

    PANA-NCE-SEC PANA-NCE-SEC defines .iso (1) .org (3) .dod (6) .internet (1) .private (4) .enterprises (1) .panasonic (258) .panasonicNetCeCommon (1) And 4 responsive OIDs are defined. To read this MIB, PANASONIC-MIB, SNMPv2-SMI, and SNMPv2-TC are required. Summary of MIBs defined in PANA-NCE-SEC: .iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).panasonic(258)
  • Page 14 DESCRIPTION Current time of the device ▪ Restrictions 12 hours notation, but can't get AM and PM panaNceEqGeneralSerialNum(13) objectName panaNceEqGeneralSerialNum object id .1.3.6.1.4.1.258.1.2.1.13 SYNTAX RANGE DisplayString (SIZE (0..47)) DESCRIPTION Serial number of the device Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 15: Pana-Security-Mib

    PANA-SECURITY-MIB This MIB defines securityProducts(5100) under panasonic(258). To read this MIB, PANASONIC-MIB, SNMPv2-SMI, and SNMPv2-TC are required. There is no definition of OID that the camera can respond to in this MIB. This MIB is required to read the PANA-CAM-MIB.
  • Page 16 Camera type ▪ Response example "fixed", "dome", "fixed_dome" camFisheye objectName camFisheye object id .1.3.6.1.4.1.258.5100.100.1.1.5 SYNTAX RANGE DisplayString (SIZE (0..255)) DESCRIPTION In the case of a fisheye camera, respond “yes”. ▪ Only fisheye cameras respond Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 17 ▪ When an error notification is received from the network monitoring system Refer to the instruction manual for each model camHourMeter objectName camHourMeter object id .1.3.6.1.4.1.258.5100.100.1.1.9 SYNTAX DisplayString (SIZE(0..4)) RANGE DESCRIPTION Years and months since the camera was manufactured. Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 18 SYNTAX RANGE Unsigned32 DESCRIPTION The limit value of pwSupplyCount. Responds when pwState is other than 1 (OK) when the number of power ON times exceeds Limit times. ▪ Note Currently, the value setting is not supported. Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 19 Make sure that the camera is connected to the correct power. Fixed cameras, fisheye cameras, cameras other than those listed above The power supply type has been changed during operation. Check if this change is ○ intended Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 20 | | + nwCamera(100) | | | + camCapabilities(1) | | | | + ImageSensor(5) | | | | | + imgSensorNumber(1) imgSensorNumber objectName imgSensorNumber object id .1.3.6.1.4.1.258.5100.100.1.5.1 SYNTAX RANGE Unsigned32 DESCRIPTION Number of image sensors Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 21 | | | | | + rs485State(1) rs485State objectName rs485State object id .1.3.6.1.4.1.258.5100.100.1.7.1 SYNTAX RANGE INTEGER { OK(1), Disabled(2), Warning(3), Failed(4) } DESCRIPTION rs485 status ▪ Restrictions Currently, there is no camera that supports the abnormal status notification (3, 4) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 22 To know the status of each IO, attach the index of the monitored IO to all the columns in the table. Response example: Index ioIndex ioName ioAlarm ioSetting ioSettingMode Terminal 1 3(None) Terminal 2 3(None) Terminal 3 3(None) ioIndex objectName ioIndex object id .1.3.6.1.4.1.258.5100.100.1.8.2.1.1 SYNTAX RANGE INTEGER (SIZE (0..255)) DESCRIPTION IO Indexq Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 23 Alarm is detected when opened, "no": Alarm is detected when shorted ioSettingCh objectName ioSettingCh object id .1.3.6.1.4.1.258.5100.100.1.8.2.1.6 SYNTAX INTEGER RANGE Setting / Terminal (Index) operation target camera number Setting. no DESCRIPTION response if not supported Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 24 SNMP MIB manual for i-PRO camera Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 25 One SD card is returned for each SD card. If there is no SD card slot, this table will not respond. Response example: storage storage storage storageRemainin overwrit overwriteCou storage Index Name State gCapacity eCount ntLimit Info 2000 Media Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 26 Obtain this value for each recordable time calculated by "Recording Time Calucutator for Network Camera with SD Memory Card", and replace the SD memory card if a response other than OK (1) is returned. “Recording Time Calculator for Network Camera with SD Memory Card” https://www.psn-web.net/ssbu-t/Useful_tool/sd_Calculator/index.html Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 27 “Recording Time Calculator for Network Camera with SD Memory Card” https://www.psn-web.net/ssbu-t/Useful_tool/sd_Calculator/index.html overwriteCount objectName overwriteCount object id .1.3.6.1.4.1.258.5100.100.1.10.2.1.7 SYNTAX RANGE Integer32 DESCRIPTION Overwrite count overwriteCountLimit objectName overwriteCountLimit object id .1.3.6.1.4.1.258.5100.100.1.10.2.1.8 SYNTAX RANGE Integer32 DESCRIPTION Maximum number of overwrites Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 28 Check disc If it returns to normal after a while, there Checking progress is no problem with the SD card. card Writeprotect The SD card tab is LOCK. LOCK state Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 29 ▪ When an error notification is received from the network monitoring system Disabled(2) The temperature sensor is stopped due to the power cable being disconnected. ○ Connect the power cable. Failed(4) The temperature sensor is in an abnormal state ○ Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 30 DESCRIPTION Index tempSensorName objectName tempSensorName object id .1.3.6.1.4.1.258.5100.100.1.11.2.1.2 SYNTAX RANGE DisplayString (SIZE (0..255)) DESCRIPTION identification name tempSensorState objectName tempSensorState object id .1.3.6.1.4.1.258.5100.100.1.11.2.1.3 SYNTAX RANGE INTEGER { OK(1), Disabled(2), Warning(3), Failed(4) } DESCRIPTION Sensor status Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 31 .1.3.6.1.4.1.258.5100.100.1.12.1.2 SYNTAX RANGE DisplayString (SIZE (0..255)) DESCRIPTION image Raito Example : "4_3", ”16_9”, "1_1" imageMaxFps objectName imageMaxFps object id .1.3.6.1.4.1.258.5100.100.1.12.1.3 SYNTAX RANGE DisplayString (SIZE (0..255)) DESCRIPTION Maximum frame rate. Unit fps Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 32 If you want to keep a history of setting changes by the camera administrator ▪ When an error notification is received from the network monitoring system Settings changed. If it is an unintended change, take action such as returning the setting. Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 33 SYNTAX RANGE DisplayString DESCRIPTION "Stream1", "Stream2", …"Stream4" streamTransmission objectName streamTransmission object id .1.3.6.1.4.1.258.5100.100.1.12.3.1.3 SYNTAX RANGE DisplayString DESCRIPTION Stream delivery on / off setting streamEncodingFormat objectName streamEncodingFormat object id .1.3.6.1.4.1.258.5100.100.1.12.3.1.4 SYNTAX RANGE DisplayString DESCRIPTION Stream(Index)Image capture size Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 34 | | | | | | + zoomCountLimit(3) | | | | | + focus(4) | | | | | | + focusState(1) | | | | | | + focusCount(2) | | | | | | + focusCountLimit(3) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 35 .1.3.6.1.4.1.258.5100.100.1.13.1.2 SYNTAX RANGE Unsigned32 DESCRIPTION Pan count objectName panCount object id .1.3.6.1.4.1.258.5100.100.1.13.1.2 SYNTAX Unsigned32 RANGE Number of warning starts. When the number of Count exceeds Limit, State DESCRIPTION is set to warning (3) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 36 .1.3.6.1.4.1.258.5100.100.1.13.2.2 SYNTAX RANGE Unsigned32 DESCRIPTION Tilt count objectName tiltCountLimit object id .1.3.6.1.4.1.258.5100.100.1.13.2.3 SYNTAX Unsigned32 RANGE Number of warning starts. When the number of Count exceeds Limit, State DESCRIPTION is set to warning (3) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 37 .1.3.6.1.4.1.258.5100.100.1.13.3.2 SYNTAX RANGE Unsigned32 DESCRIPTION Zoom count objectName zoomCountLimit object id .1.3.6.1.4.1.258.5100.100.1.13.3.3 SYNTAX Unsigned32 RANGE Number of warning starts. When the number of Count exceeds Limit, State DESCRIPTION is set to warning (3) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 38 .1.3.6.1.4.1.258.5100.100.1.13.4.2 SYNTAX RANGE Unsigned32 DESCRIPTION Focus count objectName focusCountLimit object id .1.3.6.1.4.1.258.5100.100.1.13.4.3 SYNTAX Unsigned32 RANGE Number of warning starts. When the number of Count exceeds Limit, State DESCRIPTION is set to warning (3) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 39 | | + nwCamera(100) | | | + camCapabilities(1) | | | | + IRLED(15) | | | | | + irLEDNumber(1) irLEDNumber objectName irLEDNumber object id .1.3.6.1.4.1.258.5100.100.1.15.1 SYNTAX RANGE INTEGER DESCRIPTION IR-LED equipped model Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 40 (1) in State of each item. ▪ When an error notification is received from the network monitoring system Disabled(2) The function is stopped by disconnecting the power cable. Connect the power ○ cable. Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 41 .1.3.6.1.4.1.258.5100.100.1.16.1 SYNTAX RANGE Unsigned32 DESCRIPTION Number of fans heaterNumber objectName fanNumber object id .1.3.6.1.4.1.258.5100.100.1.17.1 SYNTAX RANGE Unsigned32 DESCRIPTION Number of heaters defrosterNumber objectName defrosterNumber object id .1.3.6.1.4.1.258.5100.100.1.18.1 SYNTAX RANGE Unsigned32 DESCRIPTION Number of defrosters Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 42: Pana-Camtrap-Mib

    SNMP MIB manual for i-PRO camera PANA-CAMTRAP-MIB To read this MIB, PANA-CAM-MIB, PANASONIC-MIB, PANA-SECURITY-MIB, SNMPv2-SMI, and SNMPv2-TC are required. Summary of MIBs defined in PANA-CAM-MIB : + panasonic(258) | | + nwCamera(100) | | | + iProCamTrap(3) | | | | + iProCamEventType(1)
  • Page 43 03 autoTrack04(83) Auto track automatic tracking in area 04 coldStart(301) ( snmp trap only) cold start linkUp(303) ( snmp trap only) link up authenticationFailure(305) ( snmp trap only) authentication Failure Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 44 Object ID .1.3.6.1.4.1.258.5100.100.3.2.5 SYNTAX RANGE DisplayString (SIZE (0..255)) DESCRIPTION Event type of iProCamEvent Event type list: SYNTAX INTEGER { momentary(0), -- momentary start(1), -- start down(2), -- down stop(3), -- stop up(4) -- up Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 45: Trap Format

    (1.3.6.1.2.1.1.3.0) SNMPv2-MIB::snmpTrapOID.0 OID that represents the trap contents. Details will be (1.3.6.1.6.3.1.1.4.1.0) described later. The i-PRO camera responds by expanding the TRAP Extended response message. Details will be described later. SNMPv2-MIB::snmpTrapEnterprise.0 PANA-CAM-MIB::iProCamera (1.3.6.1.6.3.1.1.4.3.0) (1.3.6.1.4.1.258.5100.100.1500) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 46: Snmp General Trap

    Value of linkup sysUpTime The time since the camera started snmpTrapOID 1.3.6.1.6.3.1.1.5.4.0 (IF-MIB::linkUp.0) iProEventID 303(linkUp) iProEventName linkUp iProEventMessage linkUp iProEventUserMessage Character string set in the TRAP setting of SNMP. iProEventType 0(momentary) PANA-CAM-MIB::iProCamera snmpTrapEnterprise (1.3.6.1.4.1.258.5100.100.1500) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 47 Object Name Value of authenticationFailure sysUpTime authenticationFailure of SNMP 1.3.6.1.6.3.1.1.5.5.0 (SNMPv2- snmpTrapOID MIB::authenticationFailure.0) iProEventID 305(authenticationFailure) iProEventName authenticationFailure iProEventMessage authFail iProEventUserMessage Character string set in the TRAP setting of SNMP. iProEventType 0(momentary) PANA-CAM-MIB::iProCamera snmpTrapEnterprise (1.3.6.1.4.1.258.5100.100.1500) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 48: Trap Native Events

    PANA-CAMTRAP-MIB. PANA-CAMTRAP-MIB::iProEventName.0 Event Name (.1.3.6.1.4.1.258.5100.100.3.2.2.0) PANA-CAMTRAP-MIB::iProEventMessage.0 Detailed explanation of the event (.1.3.6.1.4.1.258.5100.100.3.2.3.0) PANA-CAMTRAP- The character string set to the existing TRAP MIB::iProEventUserMessage.0 setting of SNMP. (.1.3.6.1.4.1.258.5100.100.3.2.4.0) PANA-CAMTRAP-MIB:: iProEventType.0 0(momentary) (.1.3.6.1.4.1.258.5100.100.3.2.5.0) SNMPv2-MIB::snmpTrapEnterprise.0 PANA-CAM-MIB::iProCamera (1.3.6.1.6.3.1.1.4.3.0) (1.3.6.1.4.1.258.5100.100.1500) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 49 SNMP MIB manual for i-PRO camera Appendix Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 50: Appendix

    | | | | | | | + storageState(3) | | | | | | | + storageRemainingCapacity(4) | | | | | | | + overwriteCount(7) | | | | | | | + overwriteCountLimit(8) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 51 | | | | | | + DefrosterEntry(1) | | | | | | | + defrosterIndex(1) | | | | | | | + defrosterName(2) | | | | | | | + defrosterState(3) | | | + iProCamTrap(3) Panasonic i-PRO Sensing Solutions Co., Ltd.
  • Page 52 | | | | | + iProEventID(1) | | | | | + iProEventName(2) | | | | | + iProEventMessage(3) | | | | | + iProEventUserMessage(4) | | | | | + iProEventType(5) Panasonic i-PRO Sensing Solutions Co., Ltd.