Probewell Lab Inc.
AvailableTests
•
Quick: Tests all phases simultaneously with all loads (HL, PF, LL).
•
Custom: Tests all phases simultaneously with only one load selected by the
operator.
•
Full: Performs a Quick Test and all phases separately (only available with
polyphase meters).
•
Four-Quadrant (Wh): Performs a Quick Test at various phase angle lags
between voltage and current to test operation in all four quadrants. The
measurements are in Wh.
•
Four-Quadrant (VARh): Performs a Quick Test at various phase angle lags
between voltage and current to test operation in all four quadrants. The
measurements are in VARh.
•
Manual/Tracking: Tests the meter manually, without using a pickup.
•
Line Monitor: Analyzes the line voltage, the frequency fluctuation and the
line voltage harmonic content (THD) up to the 32nd order.
•
Creep: Performs a creep test.
•
Demand: Allows the operator to perform a KW demand test.
•
Accuracy: Verifies against a NIST-traceable electronic standard (only
available on the "Settings" page if no meter is installed).
Quick, Custom, Full, Four-Quadrant (Wh) and Four-Quadrant (VARh) test are only
available when an optical pickup is installed.
Page •26