  • Page 1 DWP-PC SERIES PRICE COMPUTING SCALE User’s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice...
  • Page 2: Table Of Contents

    CONTENTS INSTALLATION SPECIFICATIONS KEYS, DISPLAY AND CONNECTIONS GETTING STARTED INITIAL SETUP INSTRUCTION FOR USE RS232 DATA OUTPUT BATTERY POWER AND RECHARGING ERROR CODES 10. DAILY CARE AND MAINTENANCE Appendix A: - About Bi-Directional Communication...
  • Page 3: Installation

    1. INSTALLATION Because metrological legislation, installation/some metrological parameter settings are limited to be done by authorized personnel only. Do not attempt to change any of the built-in metrological parameters. Contact your dealer for more information and technical assistance. To ensure performance accuracy, do not use the instrument in where or when the environment condition falls beyond as those listed on SPECIFICATIONS.
  • Page 4: Specifications

    2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS DWP-PC Series(resolution 1:6000; unit : lb, kg,g) Model# DWP-30PC DWP-60PC 30lb 60lb Capacity Readability 0.005lb 0.01lb Common Specification Stabilisation 2 second typical time Operating 5°C - 35°C temperature AC 110V 60Hz Power supply built-in rechargeable battery 6V4AH.
  • Page 5: Keys, Display And Connections

    3. KEYS, DISPLAY AND CONNECTIONS 1. CH KEY Press this key to change status . Payment is entered by numeric keys. 2. WEIGHT UNIT KEY Press this key to shift among various weight units. 3. STORE KEY Press this key to store the unit price (200 unit price can be stored by press 0-9 numeric keys.) 4.
  • Page 6 8. ZERO KEY Press this key to set weight displayed to zero when an empty scale has drifted away from a true zero reading. 9. CE KEY Press this key to clear value entered. 10. NUMERIC KEYS Numeric keys 0 ~ 9 and decimal key. There are three windows on front panel and rear panel Weight Panel ;...
  • Page 7 11. BATTERY POWER / LEVEL INDICATOR This indicator appears to show:-  The instrument is running on the built-in rechargeable battery,  It shows the remaining battery level. 12. SPARE No assignment. 13. ZERO INDICATOR Visible when instrument at true zero weight status. 14.
  • Page 8 C. TOTAL PRICE PANEL Quantity value is shown here. D. BUBBLE LEVEL Refer to this bubble to obtain a horizontal position for the instrument. E. CHARGE STATUS INDICATOR Red = Recharging battery; Green = Charging completed. F. ON/OFF KEY Press this key to turn the instrument on or off. G.
  • Page 9: Getting Started

    4. GETTING STARTED In order to obtain accurate weighing and total price result, the instrument must be placed on a strong and level surface horizontally. Avoid using the instrument in environment where excessive wind flow, vibration and extreme temperature change exist. The instrument should be installed from any sources of excessive electrical noise.
  • Page 10: Initial Setup

    5. INITIAL SETUP 5.1 INTERNAL SETTINGS Preferred application parameters can be checked or set through internal functions. Refer to 5.4 for internal function description and setting procedures. 5.2 HOW TO ENTER AND SELECT INTERNAL FUNCTION Follow the below steps to enter and select desired parameter of an internal function.
  • Page 14: Instruction For Use

    6. INSTRUCTION FOR USE 6.1 POWER ON Powered on the instrument, instrument displays: - a. software and revision number and capacity of instrument, b. calibration count value, c. parameter set count value, d. all LCD segments, Then countdown process starts. After that, the instrument is ready for operation.
  • Page 15 Tare function is used to temporarily set the instrument to zero (such as cancelling the weight of a box or a container) in order to get the net weight result How to use function of the printer Place the weight on the scale, and then key in the price per lb(example $99), then hit the PRINT button once the DATE, TIME, NO.,NET,GROSS,PRICE,TOTAL will display on the receipt...
  • Page 16 6.4.2 Manual Tare When a container is used, follow the below steps to tare the weight of the container off to get a net weight result. a. Remove all loads from platter, b. Make sure that the Zero Indicator is on. If not, press [ZERO] to set weight reading to zero, c.
  • Page 17 a. Refer to 6.2 and 6.4 for zero, selecting preferred weight unit and tare operation, b. Enter the unit price per quantity ,Press [QTY], now the unit price is display on the Weight Panel c. Enter the quantity of the sample through the numeric keypad .It will display on the Unit Price Panel d.
  • Page 18: Rs232 Data Output

    b. The instrument: -  displays “ACC” on Weight Panel. ACC denotes data has been accumulated to memory,  displays “n” on Unit Price Panel. n donates the number of transactions which have been accumulated to memory.  Displays total accumulated value on Amount Panel ...
  • Page 19 transmission. Baud rate has to be set before proceeding to other settings. 7.1 PC (COMPUTER) MODE Weight status and data are sent under the PC (Computer) Mode). Data is transmitted in ASCII code. Data format is listed on below table. DATA BIT DESCRIPTION MOTION STATUS...
  • Page 20 7.2 PRT (PRINTER) MODE 7.2.1 Printing Current Transaction A standard printout as will be sent through the RS232 Comport when [PRINT] is pressed. Refer to Standard Printout Sample on next page for description. Number of copies sent = the number of copy set in internal function F8. Refer to 5 INITIAL SETUP for more information.
  • Page 21 Standard Printout Sample Description DATE 07.08.2010 TIME 12:08:57 Date of printing, Time of printing, M+ sequent number TARE 0.1kg Tare Weight, GROSS 0.242kg Gross Weight, 0.142kg Net weight, PRICE. 30.00 Unit price /100g Weight unit(price accordingly) TOTAL 42.60 Amount for this item, 10.
  • Page 22: Battery Power And Recharging

    8. BATTERY POWER AND RECHARGING Remaining battery power of the built-in rechargeable battery is displayed on the Battery Power / Level Indicator. 8.1 SYMBOLS AND REMAINING POWER: - Full Battery: ≥ 6.3V 2 Blocks: ≥6.0V 1Block: ≥5.7V Frame only: <5.7V 8.2 BATTERY OPERATION TIME Depends on the battery condition, a fully charge new rechargeable battery will usually give: -...
  • Page 23: Error Codes

    9. ERROR CODES Error Description Code No. Err 1 Time value error Err 2 Date value error Err 3 Exceed maximum manual zero range Err 4 Offset out of range / unstable during power on Err 5 No load cell signal detected Err 6 Tare operation error --oL--...
  • Page 24: Daily Care And Maintenance

    10. DAILY CARE AND MAINTENANCE  Clean the instrument with a soft, damp cloth. If necessary, use a mild detergent in water,  Do not use any harsh, abrasive material, acetone, volatile solvent, thinner or alcohol for cleaning,  Verify the accuracy of this unit periodically. Re-calibrate this unit if necessary.
  • Page 25 Calibration Turn on the scale and press/hold the tare key for 4 sec then Let go and it will display F1, with the “Print” button go to F10 Cal Press “Tare “ to enter ,show “P----”; the initial pass ward is 1234 . (“Alarm”...