Kinghome GJC15BY-A6NRNC5A Owner's Manual

Window type air conditioner

Advertisement

Quick Links

Owner's Manual
Original Instructions
Window Type Air Conditioner
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent
or visit www.gree.com or send an email to global@cn.gree.com for
the electronic version.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GJC15BY-A6NRNC5A and is the answer not in the manual?

Questions and answers

Summary of Contents for Kinghome GJC15BY-A6NRNC5A

  • Page 1 Owner's Manual Original Instructions Window Type Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.gree.com or send an email to global@cn.gree.com for the electronic version.
  • Page 2 GJC15BY-A6NRNC5A GJC15BY-A6NRND2A...
  • Page 3: Table Of Contents

    Contents Operation and Maintenance Installation Operation Notices Installation Notice Installation and Maintenance..17 Safety Precautions ......1 Preparation before installation..19 recautions........4 Window Types and Requirements...20 Parts Name........5 Operation Guide Installation Function and Control.......6 Installation procedure....21 Introduction of remote controller ..9 Sponge Sticking Method Instruction for fan direction and Procedures......29 adjusting........12...
  • Page 4 This appliance is not intended for use by persons (including children) with reduc- ed physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the ap- pliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance.
  • Page 5 Please read this operating manual carefully before operating the unit. Caution, risk of fire. Before use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The figures in this manual may be different with the material objects, please refer to the material objects for reference.
  • Page 6 WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn.
  • Page 7 Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 8: Safety Precautions

    Safety Precautions CAUTION When the air filter is to be Do not clean the air conditioner Ventilate the room well when used removed, do not touch the metal with water. together with a stove, etc. parts ofthe unit. It may cause an injury. Water may enter the unit and degrade An oxygen shortage may occur.
  • Page 9 Safety Precautions WARNING CAUTION “ ” WARNING Operation of Current Device NOTICE Please contact Customer Service. with a new cord - please contact Customer Service.
  • Page 10: Precautions

    Precautions Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock. purpose socket. Otherwise, it may cause r, otherwise the remote controller may be broken. o not spray water on air conditioner. It may cause electric shock or mal unction. personal injury or damage.
  • Page 11: Parts Name

    Parts Name Air outlet frame Control Fan direction panel adjusting rod Air-in panel Power cord NOTE:Panel outlook picture,just for reference,please take the real unit as standard.
  • Page 12: Function And Control

    Function and Control After putting through the power, air conditioner will give out a sound and indic- ators on control panel will be on. After that, you operate the air conditioner through remote controller or control panel. Light indicates the unit is in the temperature or delay time Set mode.
  • Page 13 3RZHU EXWWRQ Press this button can turn on or turn of f air conditioner. NOTE:Press this button to turn on air conditioner, the unit will operate in Energy Save mode; if the unit is energized after power failure, the unit will still operate according to the status before power failure.
  • Page 14 Filter check button After fan rotates for 250h totally, lamp of cleaning filter is on to remind customer clean it. Note: When user cleaned the filter, press Filter check button to clear the opera- tion time. Meanwhile, the warning indicator will turn off. button Under temperature setting status, after each pressing of “...
  • Page 15: Introduction Of Remote Controller

    Introduction of remote controller Note: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn’t have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 16 MODE button Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL, SAVE, FAN and DRY, as the following: AUTO COOL SAVE - / + button Pressing + or - button once will increase or decrease set temperature by 1°F(°C). Hold + or - button for 2s, set temperature on remote controller will change quickly.
  • Page 17 SLEEP button Press this button to go into the SLEEP operation mode. Press it again to cancel this function. This function is available in COOL, HEAT (Only for models with heating function) or DRY mode to maintain the most comfortable temperature for you.
  • Page 18: Instruction For Fan Direction Adjusting

    Instruction for fan direction adjusting You can adjust the fan direction adjusting rod to select left&right air outlet dire- ction according to your requirement. Fan direction adjusting rod You can adjust the air outlet frame to select up&down air outlet direction acc- ording to your requirement.
  • Page 19: Clean And Maintenance

    Clean and Maintenance WARNING Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock. 'R QRW ZDVK WKH DLU FRQGLWLRQHU ZLWK Zater to avoid electric shock. 'R QRW XVH YRODWLOH OLTXLG WR FOHDQ WKH air conditioner. 1.
  • Page 20: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the problem still can't be solved, please contact dealer or professional person. Phenomenon Troubleshooting Solution 3RZHU IDLOXUH" Wait after power recovery. ,V SOXJ ORRVH" 5HLQVHUW WKH SOXJ :KHWKHU WKH DLU VZLWFK LV WULSSHG Ask professional person to replace ofI RU IXVH LV EXUQW"...
  • Page 21 Whether air outlet or air inlet is Eliminate the obstacles. blocked? Under heating mode, whether The unit will stop blowing fan indoor temperature is reached No fan blowed after reaching to set temperature. to set temperature? out from air conditioner In order to prevent cold air, air Whether heating mode is conditioner will delay for a while to...
  • Page 22 Note: E3 malfunction code is only applicable foU FRROLQJ RQO\ XQLW F1/F2/F4/FJ malfunction codes are only applicable for electric KHDWLQJ PRGHO WARNING If there's below phenomenon, please turn off the air conditioner and disconnect the power immediately. After that, please contact dealer at once. 3RZHU FRUG LV RYHUKHDWLQJ RU GDPDJHG 7KHUH V DEQRUPDO VRXQG GXULQJ RSHration.
  • Page 23: Installation And Maintenance

    Installation and Maintenance 2EVHUYH DOO JRYHUQLQJ FRGHV DQG RUGLQDQFHV 'R QRW XVH GDPDJHG RU QRQVWDQGDUG pRZHU FRUG %H FDXWLRQ GXULQJ LQVWDOODWLRQ DQG PDLQWHQDQFH 3URKLELW LQFRUUHFW RSHUDWLRQ WR SUHYHQW HOHFWULF VKRFN FDVXDOW\ DQG RWKHU DFFLGHQWV Selection of Installation Location Basic requirement IQVWDOOLQJ WKH XQLW LQ WKH fROORZLQJ SODFHV PD\ FDXVH PDOfXQFWLRQ If LW LV XQDYRLGDEOH SOHDVH FRQVXOW WKH ORFDO GHDOHU YRODWLOH REMHFWV VSUHDG LQ WKH DLU...
  • Page 24 Requirements for Electric Connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. and air switch. 3. Make sure the power supply matches with the requirement of air conditioner. hazard or malfunction. 4. Please make sure the power supply complies with the requirement of air conditioner.
  • Page 25: Preparation Before Installation

    Preparation before installation Phillips screwdriver Screwdriver Level bar Scissors Pencil Measuring tape Window type unit Sealing strip ( without adhesive) Upper guide rail Sealing strip ( with adhesive)(2) Sponge R1 Sealing sponge Sealing strip ( with adhesive)(2) Left tripod (1) Right tripod (1) of flexible screen(2) Type A screw (10)
  • Page 26: Window Types And Requirements

    Window types and requirements NOTICE: The description for below installation is for the standard window. If it’s other types of window, you may need to adjust the window. ,I \RX QHHG WR LQVWDOO WKH DLU FRQGLWLRQHU DW WKH VPDOO ZLQGRZ, you may not need for details.
  • Page 27: Installation Procedure

    Installation procedure Location How to install: Choose a location where there are no 500mm 500mm any obstacle surrounding the unit, and the plug is accessible. Choose the installation space ac- cording to the following diagram. The distance between the air conditioner 300mm 300mm and the around obstacles should meet the...
  • Page 28 Note: When removing the front case, pull out the bottom and then lift the front case upwards to remove it. control panel screw front case screw screw screw at the two sides of outer case, and then pull out the main unit from the outer case.
  • Page 29 Tear off the binder fixing gasket and then take out the gasket and binder. gasket Step 2: Install upper guide rail Tear off the paster at the back of sealing strip, and then align it at the bottom edge of upper guide rail to stick the sealing strip at the bottom of upper guide rail.
  • Page 30 2. Stick one sealing strip respectively on the left side and right side of flexible screen installation frame, as shown in the figure. A: Tighten screws from inside to B: Tighten screws from outside outside of outer case. to inside of outer case.
  • Page 31 Step 4: Stick sealing strip Stick the sealing strip (with adhesive) at the bottom of window frame. Sealing strip ( with adhesive) Step 5: Install outer case Put the outer case at the windowsill, and the lower guide rail should be stuck to the windowsill.
  • Page 32 outer case type E screw supporter 3. Adjust the position of screw connecting the tripod and supporter into order (Note: The outer case should be placed horizontally or inclined outwards slightly.) horizontal or inclined about 3° 3° Can be moved vertically to adjust the gradient of...
  • Page 33 plastic window wooden window Step 7: Plug sealing strip Plug the sealing strip (without adhesive) in the window. Step 8: Install main unit 1. Ask two persons to push the main unit slowly into the outer case.
  • Page 34 l cover with screw. screw screw grounding screw case at the top of outer case, and then push the bottom of front case)
  • Page 35: Sponge Sticking Method And Procedures

    Sponge Sticking Method and Procedures 1. Install flexible screen sub-assy. After finishing installation, measure the width L between outer case of air conditioner and window frame. 2. Take out R1 sponge from the package. Cut off the sponge in rectangular shape with scissors.
  • Page 36: Safety Operation Of Flammable Refrigerant

    Safety operation of flammable refrigerant  All the work men who are engaging in the refrigeration system should bear the for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised 2.
  • Page 37 Welding 1. If you should cut or weld the refrigerant system pipes in the process of maintain- ing, please follow the steps as below a. Shut down the unit and cut power supply b. eliminate the refrigerant c. vacuuming d. clean it with N e.
  • Page 38 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com Web: www.gree.com 600005062249...

This manual is also suitable for:

Gjc15by-a6nrnd2a

Table of Contents