TECHNICAL CHARACTERISTICS

Power circuit
Input voltage
Frequency
Maximum consumption
Environmental conditions
Temperature range
Humidity range
Mechanical characteristics
Enclosure material
Protection grade
Unit dimensions (Width x Height x Length)
Weight
Mounting
Maximum working altitude
Serial interface
Type
Baud rate
Data bits
Parity
Stop bits
Characteristics and electrical security
Security
Protection class
External current transformers
Standards
Standards

CONNECTIONS AND LEDS

Input voltage of SEM One is connected at terminals L1 and N and external current transformers are used for current
metering. Next are detailed all connections and leds:
SEM One
110 .... 264 Vac
47 .... 63 Hz
2,5 .... 4,5 VA
-10 .... +60ºC
5 .... 95%
Plastic UL94 – V0 Self-extinguishable
IP30
18 x 70 x 109 mm
70 g
DIN Rail (1 module)
2000 m
RS-485 three wires
9600 / 19200 / 38400 / 57600 / 115200 bps configurable
8
Without parity / Even configurable
1 / 2 configurable
CAT III 300 V under EN 61010
Class II
Series TRC and TRA (In / 0,250 A)
UNE EN 61010-1:2010, UNE-EN 61000-6-2, UNE-EN 61000-6-4
V01-090817

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SEM One and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PickData SEM One

  • Page 1 Standards UNE EN 61010-1:2010, UNE-EN 61000-6-2, UNE-EN 61000-6-4 CONNECTIONS AND LEDS Input voltage of SEM One is connected at terminals L1 and N and external current transformers are used for current metering. Next are detailed all connections and leds: V01-090817...
  • Page 2 INSTALLATION The SEM One unit must be installed on an electric panel or enclosure, attached to a DIN rail (IEC 60715). The unit must be connected to a power circuit that is protected with gl (IEC 269) or M type fuses with a rating of 0.5 to 2 A.
  • Page 3 UNE EN 61010-1:2010, UNE-EN 61000-6-2, UNE-EN 61000-6-4 CONEXIONADO Y LEDS La alimentación de SEM One se realiza entre los bornes de L1 y N, y se requieren transformadores de corriente externos para la medida de corriente. A continuación el detalle de cada borne:...
  • Page 4 Web. MANTENIMIENTO Y SERVICIO TÉCNICO El equipo no requiere mantenimiento. En caso de cualquier duda de funcionamiento o avería del equipo contactar con el servicio técnico de PickData, SL PickData, SL - Servicio de Asistencia Técnica Calle Innovació, 3 08232 –...

Table of Contents