TECHNICAL CHARACTERISTICS

Power circuit
Input voltage
Frequency
Maximum consumption
Environmental conditions
Temperature range
Humidity range
Mechanical characteristics
Enclosure material
Protection grade
Unit dimensions (Width x Height x Length)
Weight
Mounting
Maximum working altitude
Radio communication
Protocol
Frequency
External antenna connector
External antenna connector type
Autosync sensor-gateway
Temperature metering
Probe type
Number of probes included
Digital inputs characteristics
Type
Maximum activation current
Outputs characteristics
Type
Nominal voltage
Electrical endurance
Nominal current
With resistive charge
With inductive charge (CA)
With inductive charge (CC)
Characteristics and electrical security
Security
Electric shock protection
Standards
Standards
TIR Two
TIR Two (Temperature Inputs Relays) is a digital signals and impulse
centralizer. In only 4 DIN modules, the unit has 2 relay outputs, 2 voltage
free digital inputs and 2 NTC/PTC inputs for temperature sensors.
The device works with LoRa
communications, with maximum communication's range of 1 km indoor and
up to 20 outdoor with direct line of sight.
All setup in radio communications is done using the dip-switch located in
the lower part of the device. Once the configuration is completed, TIR Two
devices connect automatically with Gateway LR for a fast and easy
110 ... 264 Vac
47 ... 63 Hz
2,5 .... 4,5 VA
-10 .... +60ºC
5 .... 95%
Plastic UL94 – V0 Self-extinguishable
IP20
18 x 70 x 109 mm
70 g
DIN Rail (1 module)
2000 m
LoRa
TM
868 / 915 MHz configurable
Yes
SMA female
Yes
NTC/PTC
1
Free voltage
5 mA
Relay
250 Vac
3 x 10
operations (5 A A.C.)
4
250 Vac / 5 A A.C.
250 Vac / 2 A A.C.
24 Vdc / 5 A D.C.
CAT III 300 V under EN 61010
Double insulation class II
UNE EN 61010-1:2010, UNE-EN 61000-6-2, UNE-EN 61000-6-4
TM
protocol for long range radio
V01-050417

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TIR Two and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PickData TIR Two

  • Page 1 20 outdoor with direct line of sight. All setup in radio communications is done using the dip-switch located in the lower part of the device. Once the configuration is completed, TIR Two devices connect automatically with Gateway LR for a fast and easy installation.
  • Page 2 INSTALLATION TIR Two has been designed for DIN rail mounting. IMPORTANT Take into account that when the device is connected, the terminals may be hazardous to the touch, and opening the covers or removing elements may provide access to parts that are dangerous to the touch.
  • Page 3 Digital input 2 Relay 1 OUT1 Relay 2 OUT2 MODEL REFERENCE Model Reference Protocol Communication TIR Two C005 LoRa Radiofrequency TEMPERATURE PROBE REFERENCE In case that an extra temperature probe is needed: Model Reference Cable length Connection type Probe NTC 15...
  • Page 4 National Electrical Code. DISCLAIMER PickData, SL reserves the right to make modifications to the device or the unit specifications set out in this instruction manual without prior notice. PickData, SL on its web site, supplies its customers with the latest versions of the device specifications and the most updated manuals.

Table of Contents