TECHNICAL CHARACTERISTICS

Power circuit
Input voltage
Frequency
Maximum consumption
Environmental conditions
Temperature range
Humidity range
Mechanical characteristics
Enclosure material
Protection grade
Unit dimensions (Width x Height x Length)
Weight
Mounting
Maximum working altitude
Serial interface
Type
Baud rate
Data bits
Parity
Stop bits
Characteristics and electrical security
Security
Electric shock protection
Standards
Standards

CONNECTIONS AND LEDS

RS-485 COMMUNICATION

The device comes equipped with a RS-485 communication port to read and write the parameters of the device or other devices
connected. The protocol used is Modbus RTU.
By default the device is configured with peripheral number 1 (decimal) and communication mode 0 (9600 bps, 8, N, 1). Using
the command for changing the device number it is possible to assign any other number (maximum FF in hexadecimal or 255 in
decimal).
In case you don't remember the slave number, you can return to default number and communication mode following this steps:
Press and hold for 10 seconds the reset button.
Stop pressing the reset button (leds will blink several times) and the device will recover all factory default settings.
Bridge LR 230 VAC
110 ... 264 Vac
47 ... 63 Hz
2,5 .... 4,5 VA
-10 .... +60ºC
5 .... 95%
Plastic UL94 – V0 Self-extinguishable
IP20
18 x 70 x 109 mm
70 g
DIN Rail (1 module)
2000 m
RS-485 three wires
9600 / 19200 / 38400 / 57600 / 115200 bps configurable
8
Without parity / Even configurable
1 / 2 configurable
CAT III 300 V under EN 61010
Double insulation class II
UNE EN 61010-1:2010, UNE-EN 61000-6-2, UNE-EN 61000-6-4
Led
Description
ON
Power
Activity: Green led on
-
RF
LoRa
radiofrequency
TM
Data transmission: Red slow blinking
-
Data reception: Green rapid blinking
-
Silence/waiting time: Blue led on
-
(only on Master mode)
COM
RS-485
Data transmission: Red rapid blinking
-
Data reception: Green rapid blinking
-
V05-060619

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LR 230 VAC and is the answer not in the manual?

Questions and answers

Summary of Contents for PickData LR 230 VAC

  • Page 1 Bridge LR 230 VAC Please note that this document is only a shot user manual and does not handle every function. The complete manual is available at www.pickdata.net TECHNICAL CHARACTERISTICS Power circuit Input voltage 110 … 264 Vac Frequency 47 … 63 Hz Maximum consumption 2,5 ….
  • Page 2 Pay special attention to the installation standards of the National Electrical Code. DISCLAIMER PickData, SL reserves the right to make modifications to the device or the unit specifications set out in this instruction manual without prior notice.
  • Page 3 Bridge LR 230 VAC Tenga en cuenta que este documento es únicamente una manual de usuario en versión reducida y no contiene todas las funcionalidades del equipo. El manual completo puede ser descargado en www.pickdata.net CARACTERÍSTICAS TÉCNICAS Circuito de alimentación Alimentación...
  • Page 4 Código Eléctrico Nacional. LIMITACIÓN DE RESPONSABILIDAD PickData, SL se reserva el derecho de realizar modificaciones, sin previo aviso, del dispositivo o a las especificaciones del equipo, expuestas en el presente manual de instrucciones.

Table of Contents