INDUSTRIAL DEHUMIDIFIER
OPERATING ISSUE
The unit is not working.
The unit shuts down and displays
an error code.
PAGE 1 OF 6
1-800-295-5510
uline.com
TROUBLESHOOTING
CAUSES
The breaker tripped.
The unit is plugged into a GFI protected
circuit.
The unit is being run from a generator.
The extension cord is not the correct
gauge for the distance run.
(14 AWG up to 25' and 12 AWG over 25')
ER 1: Overflow switch remaining closed
for over two minutes.
Plugged or kinked drain hose.
Bad connection in pump circuit.
Defective condensate pump.
ER 2: Internal pressure switch indicates
refrigerant pressure is too high.
Air filter is dirty or plugged.
The coil is dirty.
Loose or faulty electrical connections
to pressure switch.
Fan is not working.
Defective pressure switch.
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
RECOMMENDATIONS
Reset breaker.
Remove from area. Excessive moisture will trip GFI.
Check output does not fluctuate, as the unit will
not operate at low voltage.
Verify voltage while unit is starting. Start up will
cause the highest current draw and largest
voltage drop. Even if plugged directly to outlet,
there can be a significant voltage drop. Never
assume the voltage is okay without verifying.
Remove obstruction.
Check connections.
Replace pump.
Clean or replace air filter.
Clean coil.
Check connections.
Replace fan.
Replace pressure switch.
0621 TH-6621

Advertisement

loading
Need help?

Need help?

Do you have a question about the Н-6621 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for U-Line Н-6621

  • Page 1 Para Español, vea páginas 3-4. Pour le français, consulter les pages 5-6. H-6621 1-800-295-5510 uline.com INDUSTRIAL DEHUMIDIFIER TROUBLESHOOTING OPERATING ISSUE CAUSES RECOMMENDATIONS The unit is not working. The breaker tripped. Reset breaker. The unit is plugged into a GFI protected Remove from area.
  • Page 2 TROUBLESHOOTING CONTINUED OPERATING ISSUE CAUSES RECOMMENDATIONS The unit continually ices up. No warm air is blowing out of the back Ambient temperature may be too low. Raise of the unit. temperature with supplementary source. NOTE: Some ice buildup on the evaporator coil Air filter is dirty and airflow is obstructed.
  • Page 3: Solución De Problemas

    π H-6621 800-295-5510 uline.mx DESHUMIDIFICADOR INDUSTRIAL SOLUCIÓN DE PROBLEMAS PROBLEMA OPERATIVO CAUSAS RECOMENDACIONES La unidad no está funcionando. El interruptor automático se botó. Reinicie el interruptor automático. Retire del área. La humedad excesiva hace que el La unidad está conectada a un circuito protegido con un interruptor de circuito de GFI se bote.
  • Page 4 CONTINUACION DE SOLUCIÓN DE PROBLEMAS PROBLEMA OPERATIVO CAUSAS RECOMENDACIONES La unidad se escarcha No sale nada de aire caliente de la parte La temperatura ambiente puede estar muy continuamente. posterior de la unidad. baja. Suba la temperatura con una fuente complementaria.
  • Page 5: Dépannage

    π H-6621 1-800-295-5510 uline.ca DÉSHUMIDIFICATEUR INDUSTRIEL DÉPANNAGE PROBLÈME DE FONCTIONNEMENT CAUSES RECOMMANDATIONS L'appareil ne fonctionne pas. Le disjoncteur a été déclenché. Réinitialisez le disjoncteur. L'appareil est branché sur un circuit protégé Enlevez l'appareil de la zone à sécher. Une par le DDFT. humidité...
  • Page 6 DÉPANNAGE PROBLÈME DE FONCTIONNEMENT CAUSES RECOMMANDATIONS De la givre se forme continuellement L'air chaud ne souffle pas à l'arrière de La température ambiante peut être trop basse. sur l'appareil. Augmentez la température avec une source l'appareil. supplémentaire. REMARQUE : Une certaine Le filtre à...