RPB NOVA 3 Instruction Manual
Hide thumbs Also See for NOVA 3:

Advertisement

Quick Links

INSTRUCTION
MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NOVA 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for RPB NOVA 3

  • Page 1 INSTRUCTION MANUAL...
  • Page 2 Parts and Acessories RPB Safety T: 1-866-494-4599 F: 1-866-494-4509 E: info@rpbsafety.com www.rpbsafety.com RPB, advancing your safety and NOVA 3 are registered trademarks of RPB Safety For technical assistance contact out Customer Service Department on 1-866-494-4599 or email: customerservice@rpbsafety.com RPB 155 /1...
  • Page 4 NV2016 Flow Control Valve, 4000-01 Cold Air Tube and the 4000-20 Hot Air Tube. All RPB Safety products are covered by a manufactures warranty of 3 months. The manufacturer warranty covers defects in material, workmanship DQG GRHV QRW FRYHU GDPDJH FDXVHG E\ PLVXVH RU DEXVH 53% 6DIHW\·V RQO\...
  • Page 5: Respirator Component Concept

    ® RESPIRATOR COMPONENT CONCEPT The NOVA 3 Supplied Air Respirator consists of 4 main components: Respirator Helmet Assembly ‡ ‡ Respirator Cape ‡ Breathing Tube Assembly Air Supply Hose ‡ All 4 components must be present and properly assembled to constitute a complete NIOSH Approved Respirator.
  • Page 6 :$51,1*6 'R QRW XVH WKLV UHVSLUDWRU XQWLO \RX KDYH EHHQ WUDLQHG LQ WKH UHVSLUDWRUV XVH PDLQWHQDQFH DQG OLPLWDWLRQV E\ D TXDOLILHG LQGLYLGXDO DSSRLQWHG E\ \RXU HPSOR\HU ZKR KDV H[WHQVLYH NQRZOHGJH RQ WKH 129$  5HVSLUDWRU $OO WUDLQLQJ PXVW EH LQ DFFRUGDQFH ZLWK WKLV 8VHUV ,QVWUXFWLRQ 0DQXDO %HIRUH XVLQJ WKLV UHVSLUDWRU HQVXUH \RXU HPSOR\HU KDV GHWHUPLQHG WKDW DLUERUQH FRQWDPLQDQW FRQFHQWUDWLRQV GR QRW...
  • Page 7 G-7.1. The respirator must be supplied with clean breathable air at all times. A carbon monoxide monitor must be used at all times. Contact your RPB distributor for a Radex 08-200 CO Monitor. RPB Safety cannot accept any liability of whatsoever nature...
  • Page 8 RPB Safety products, including purposes that the products are not designed for. RPB Safety is not liable for damage, loss or expense resulting from the failure to give advice or information or the giving of incorrect advice or information, ZKHWKHU RU QRW GXH WR 53% 6DIHW\·V QHJOLJHQFH RU WKDW of its employees, agents or sub-contracters.
  • Page 9 Š 5HFRPPHQGDWLRQ :KHQ XVLQJ D 129$  6XSSOLHG $LU 5HVSLUDWRU ,W LV UHFRPPHQGHG WR XVH D 5DGH[ $LUOLQH )LOWHU SQ  DQG D FDUERQ PRQR[LGH PRQLWRU SQ  1,26+  &$87,216 $1' /,0,7$7,216 1RW IRU XVH LQ DWPRVSKHUHV FRQWDLQLQJ OHVV WKDQ  SHUFHQW R[\JHQ 1RW IRU XVH LQ DWPRVSKHUHV LPPHGLDWHO\ GDQJHURXV WR OLIH RU KHDOWK...
  • Page 10: Operation

    Type 1 gaseous air described in the Compressed Gas Association Commodity Specifications G.7.1 (Grade D or higher) and as specified by Federal Law 42 CFR 84, subpart J.84.141(b) and 29 CFR 1910.134 (i) the NOVA 3 does not purify air or filter contaminants. AIR SOURCE Locate the air source in a clean air environment, always use a filter on the inlet of your air source.
  • Page 11: Breathing Air Pressure

    The NOVA 3 Breathing Air Pressure table on page 11 defines the air pressure ranges needed to provide the respirator with a volume of air which falls in the required range of 6-15cfm or 170-425 Its/min.
  • Page 12: Breathing Air Pressure Table

    BREATHING AIR PRESSURE TABLE This table lists air pressure ranges needed to provide the NOVA 3 with the volume of air that falls within the required range of 6-15cfm or 170-425 lts/min according to U.S government regulations. Fig. 2.1 Air Source...
  • Page 13: Setup And Use

    INNER LENS Fig. 3.1 Fig. 3.2 Place RPB Inner lens (NV3-722) into the left of the Secure locating Inner lens frame pins into visor Inner lens frame (NV3-723) and work it round latch mount rolling the frame round the inner...
  • Page 14: Connecting The Air Supply

    TEAR OFF AND OUTER LENSES (cont.) Fig. 3.4 Fig. 3.5 Place the lenses onto the Lens Slide the lenses under the lens Locator at the centre of the visor locators that are positioned at the p/n: N3-726. sides of the visor. CONNECTING THE AIR SUPPLY Fig.
  • Page 15 Š &211(&7,1* 7+( $,5 6833/< FRQW )LJ  )LJ  &RQQHFW WKH %UHDWKLQJ $LU 6XSSO\ 1RZ FRQQHFW WKH %UHDWKLQJ $LU +RVH 19  19 WR WKH 6XSSO\ +RVH WR WKH )ORZ &RQWURO SRLQW RI DWWDFKPHQW  'HYLFH $LU VKRXOG EH QRZ IORZLQJ 5DGH[ $LUOLQH )LOWHU VKRZQ WKURXJK WKH 5HVSLUDWRU :$51,1*...
  • Page 16 '211,1* <285 +(/0(7 FRQW )LJ  )LJ  $GMXVW WKH 5HVSLUDWRU SDGGLQJ VL]H )ROG EDFN FDSH RSHQ WKH ,QQHU E\ WXUQLQJ WKH UDWFKHW NQRE ORFDWHG %LE DQG SODFH \RXU ILQJHUV RQ WKH XQGHU WKH FDSH FROODU DW WKH EDFN ,QQHU %LE DQG WKH VLGH RI KHOPHW DW RI WKH UHVSLUDWRU SDGGLQJ DSSUR[LPDWHO\ HDU SRVLWLRQ /LIW WKH KHOPHW DQG SODFH RQWR \RXU KHDG...
  • Page 17 Š '211,1* <285 +(/0(7 FRQW )LJ  )LJ  )DVWHQ WKH 19 EHOW DW ZDLVW RU 5H FKHFN WKH DLU SUHVVXUH DQG KLS OHYHO DQG DGMXVW IRU FRPIRUW DGMXVW LI QHFHVVDU\ :LWK DLU IORZ 0RYH WKH )ORZ &RQWURO 'HYLFH LQWR \RXU UHVSLUDWRU \RX DUH QRZ DZD\ IURP VSLQH UHDG\ WR HQWHU WKH ZRUN DUHD '2)),1* <285 +(/0(7...
  • Page 18: Inspection & Maintenance

    CLEANING STORAGE – As the NOVA 3 Supplied Air Respirator has a limited service life, a regular inspection and replacement programme must be conducted. Before using the Respirator all parts should be inspected for damage or wear and tear. Replace all worn or damaged parts immediately.
  • Page 19 Š +(/0(7 $1' /,1,1*6 FRQW )LJ  )LJ  5HPRYH +HDG /LQHU SDGGLQJ IURP 5HPRYH UHDU SDG WKH KHDG OLQHU WKH SDGGLQJ FDQ EH ZDVKHG RU GLVSRVHG 7KH SDGGLQJ LV VHFXUHG ZLWK KRRN IDVWHQHUV )LJ  )LJ  7KH LQVLGH RI WKH KHOPHW FDQ EH 2U LI \RX QHHG WR UHPRYH WKH ZLSHG FOHDQ ZLWK D OLTXLG FRPSOHWH +HDG /LQHU ILUVW UHPRYH...
  • Page 20: Breathing Tube Assembly

    Check Inner Lens Gasket p/n NV3-721 and the Inner Lens Frame p/n NV3-723 for splits, cracks or wear and tear. Replace any damaged or worn parts immediately with RPB Safety genuine parts. The Inner Gasket and Inner Lens fame can be sponged with warm water and a gentle detergent, rinsed and air dried.
  • Page 21 Do not run water through the inside of the hose. Clean the Quick Disconnect Couplings with an air blow down gun to remove any sand or dirt that may jam the coupler. !WARNING! USE ONLY NIOSH APPROVED RPB SAFETY AIR SUPPLY HOSES.
  • Page 22 6725$*( )LJ  $IWHU WKH UHVSLUDWRU FRPSRQHQWV KDYH EHHQ FOHDQHG DQG LQVSHFWHG SODFH WKHP LQ D SODVWLF EDJ RU DQ DLUWLJKW FRQWDLQHU 6WRUH UHVSLUDWRU SDUWV DZD\ IURP H[FHVVLYH KHDW GXVW FROG PRLVWXUH DQG KDUPIXO FKHPLFDOV )LJ  $IWHU \RX KDYH XVHG WKH UHVSLUDWRU KDQJ LW XS E\ WKH KDQG VWUDS LQ D FOHDQ HQYLURQPHQW WKLV ZLOO KHOS NHHS WKH LQVLGH IUHH RI...
  • Page 23 Š 3$576 $1' $&&(6625,(6 )LJ  +HOPHW &RPSRQHQWV )LJ  3DGGLQJ 6\VWHP )LJ  9LVRU DQG /HQVHV )LJ  5HVSLUDWRU &DSHV )LJ  %UHDWKLQJ 7XEH )ORZ &RQWURO 'HYLFHV )LJ  )LOWUDWLRQ 0RQLWRULQJ 3OHDVH UHIHU WR 53% &DWDORJ $LU 6XSSO\ +RVH )LJ  :$51,1* 7KH XVH RI XQDSSURYHG UHSODFHPHQW SDUWV YRLGV WKH DSSURYDO RI WKH HQWLUH UHVSLUDWRU...
  • Page 24 HELMET COMPONENTS - Fig 7.2 All kits contain screws and nuts NV3-727-2 when necessary NV3-729 NV3-730 NV3-727/8 NV3-759 NV3-727-2 - Visor Hinge Lock NV3-727/8 - Visor Latche Mount Kit - Includes: Latch Mount, Hinge Mount, Covers NV3-729 - Air Inlet Kit - Includes: Air Inlet, O-Ring, Back Plate, Hanging Strap NV3-730 - Padding Connectors (left &...
  • Page 25 ® INSTRUCTION MANUAL BREATHING TUBE & FLOW CONTROL DEVICE - Fig 7.4 NV2016 4000-20 4000-01 NV2021B NV2022 NV2021B - Breathing Tube (dark grey) NV2022 - Belt NV2016 - Flow Control Valve Assembly - Includes: Flow Control Valve, Belt 4000-01 - Cool Air Tube Assembly - Includes: Cool Air Tube, Belt 4000-20 - Hot Air Tube Assembly -...
  • Page 26 PADDING SYSTEMS - Fig 7.6 NV3-734 NV3-735-1 07-900 NV3-734-1 NV3-733 NV3-735 NV3-732 NV3-731 NV3-731 - Side Padding Frames (left & right) NV3-732-XXX - Side Padding, where XXX indicates size and style. Contact your distributor for options NV3-733 - Side Padding Covers (left & right) NV3-734 - Head Liner Kit - Includes: Head Liner, Head Liner Foam Padding, Head Liner Clips x4...
  • Page 27 Š 0$,17(1$1&( 5(&25' 'DWH 0DLQWHQDQFH 'HWDLOV 6LJQHG...
  • Page 28 The RADEX Airline Filter offers you more capacity, versatility & filtration. You can combine the versatility of either floor or wall mounting with increased filtration capacity. Our range of optional equipment means you can customize your filter to meet your requirements. RPB 155/1 1-866-494-4599 www.rpbsafety.com...

Table of Contents