Hide thumbs Also See for ASTRO:

Advertisement

Available languages

Available languages

Quick Links

INSTRUCTION MANUAL
2797
EN14594:2005 3B
RESPIRATORY PROTECTION
BSI Certified Product
AS/NZS 1716:2012
BMP# 714303
RESPIRATORY PROTECTION
ENGLISH
EN
NEDERLANDS
NL
EMPLOYERS: read this manual and the flow control device instruction
manual and carry out the employer responsibilities (page 8).
PRODUCT USERS: read this manual and the flow control device instruction
manual and follow the product user safety instructions (page 10).
Manuals are regularly updated. Make sure this manual is available to all
users for reference.
CURRENT VERSION OF MANUAL AND OTHER LANGUAGES:
rpbsafety.com/respirators/astro
The Respiratory Protection
2
25
Brand
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASTRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RPB ASTRO

  • Page 1 PRODUCT USERS: read this manual and the flow control device instruction manual and follow the product user safety instructions (page 10). Manuals are regularly updated. Make sure this manual is available to all users for reference. CURRENT VERSION OF MANUAL AND OTHER LANGUAGES: rpbsafety.com/respirators/astro The Respiratory Protection Brand ®...
  • Page 2: Table Of Contents

    DANGER Indicates a hazardous situation that, if not avoided, will result in DANGER death or serious injury. Read the Instruction Manual. Additional copies of RPB manuals can be found at rpbsafety.com. ® CERTIFIED BY: BSI Group The Netherlands B.V. (NB 2797) Say Building, John M.
  • Page 3: Introduction

    The green and gray color combination is a registered trademark of RPB Safety, LLC. All rights in the RPB Intellectual Property contained in this publication, including copyright, trademarks, service marks, trade secret, and patent rights are reserved.
  • Page 4: Important Safety Information

    EN 14594 approved respirator with an Assigned Protection Factor of 40 (Nominal Protection Factor of 1000). As such, it significantly reduces, but does not completely eliminate, the breathing of contaminates by the respirator wearer. Use with an airline filter, such as the 04-900 RPB ®...
  • Page 5 FACE AND EYES:  The ASTRO respirator with Inner Lens DOES NOT meet EN 166:2001 (AS/NZS 1337.1:2010) ® requirements.  The ASTRO is not designed or tested to provide protection against molten metals or corrosive ® liquids.  Note: Safety glasses may be required to be worn depending on the job hazard analysis. The...
  • Page 6: Respiratory Component Diagram - Cautions & Limitations

    ASTRO ® RESPIRATOR COMPONENT CONCEPT The RPB ASTRO Respirator consists of three main components: Respirator Helmet Assembly, ® ® Breathing Tube Assembly, And Air Supply Hose. All three components must be present and properly assembled to constitute a complete EN 14594 (AS/NZS 1716) approved Respirator.
  • Page 7: Air Source, Fittings, And Pressure

    1715 requirements. AIR QUALITY This respirator must be supplied with clean breathable air at all times. Breathable air must at least meet the requirements for EN 12021 and AS/NZS 1715. The RPB ASTRO does not purify air or filter ®...
  • Page 8: Employer Responsibilities

    ASTRO ® EMPLOYER RESPONSIBILITIES Your specific responsibilities may vary by location and industry, but in general RPB expects that ® employers will:  Follow all applicable standards and regulations for your location, industry, and activity. Depending on your location and industry, a number of standards and regulations may apply to your selection and use of respirators and other personal protective equipment.
  • Page 9 (e.g. regarding respirable silica). Refer to rpbsafety.com/important-safety-information/ for links to websites that can provide regulatory guidance.  If you have any questions, contact RPB ®  Call Customer Service Department: Tel: 1-866-494-4599 Email: customerservice@rpbsafety.com...
  • Page 10: Product User Safety Instructions

    ® you are using. MAKE SURE THE SYSTEM IS READY FOR USE Make sure you have a complete system. Verify that you have all required components for the ASTRO ® to serve as a complete approved respirator:  Respirator Helmet Assembly (ASTRO ®...
  • Page 11 (page 17) for fit information. VERIFY THAT YOU HAVE THE APPROPRIATE EQUIPMENT FOR YOUR ACTIVITY Verify that the ASTRO provides appropriate protection for your activity. As applicable, check your ® workplace safety program, respiratory protection program, and standards and regulations for your activity or industry.
  • Page 12 PRODUCT USER SAFETY INSTRUCTIONS CONTINUED PRODUCT CARE Never place the helmet on hot surfaces. Do not apply paints, solvents, adhesives or self-adhesive labels except as instructed by RPB . This product may be adversely affected by certain chemicals. ® Clean and disinfect with warm water and mild detergent or a disinfecting wipe. See the “Respirator Setup and Use”...
  • Page 13: Breathing Air Pressure Table

    BREATHING AIR PRESSURE TABLE S - SPECIAL OR CRITICAL USERS INSTRUCTIONS - SAR TABLE 1.1 This table lists air pressure ranges needed to provide the RPB ASTRO with the volume of air that ® ® falls within the required range of 6-15cfm or 170-425 lts/min according to government regulations.
  • Page 14: Respirator Setup And Care

    Place the lens into the face frame and push past the locating ribs. NOTE Always make sure that a RPB Safety inner lens is securely fitted into the window frame gasket. ® Proceed fitting lenses as Fig 3.1, Fig 3.2, Fig 3.3.
  • Page 15 VISOR REPLACEMENT FIGURE 3.4 FIGURE 3.5 Remove the old visor by removing the To install the replacement visor with a screws and nuts holding on the visor. standard lens, place the visor onto the helmet and insert the attachment spacers with “3”...
  • Page 16 ASTRO ® RESPIRATOR SETUP AND CARE CONTINUED SETTING UP Head Harness To adjust the head harness first unclip the locating pegs, then slide the band in or out to the desired size. Note: slide inwards to reduce the size. Once the desired size is obtained, clip the locating pegs back together.
  • Page 17: Donning And Doffing

    Not doing these steps could expose you to hazardous materials and contaminants that could impair the function of the respirator. DONNING YOUR HELMET Once you have completed the set up, you are ready to fit your RPB ASTRO . Firstly check inside ®...
  • Page 18 ASTRO ® DONNING AND DOFFING CONTINUED FIGURE 6.3 FIGURE 6.4 Now bring both buckles together at the front Now the helmet is fully fitted and the belt and push them until you hear a click. Pull tightened. Again check the air pressure the tab to tension the belt.
  • Page 19: Inspection And Cleaning

    Certain parts such as lenses must be replaced frequently. All components of the respirator assembly should be inspected for damage or wear and tear before use. Replace worn or damaged parts immediately. USE ONLY RPB ASTRO parts. Refer to the ®...
  • Page 20 ASTRO ® INSPECTION, CLEANING AND DISINFECTING CONTINUED REMOVING THE CAPE INSPECTING THE HELMET FIGURE 7.1 FIGURE 8.1 First remove the cape cover band to reveal Having removed the cape, wipe out the the eight snaps. The cape can then easily be inside of the helmet with a soft cloth and removed by undoing the snaps.
  • Page 21: Parts And Accessories

    PARTS AND ACCESSORIES VISOR AND LENSES FIGURE 10.1 02-806 02-807 02-804 02-811-015 02-805 02-810 02-816 02-809 02-808 Part No. Description Part No. Description 02-804 Visor 02-809 Head Suspension 02-805 Visor Strap 02-810 Inner Lens (pkt 10) 02-806 Cleat 02-811-015 Outer Lens (pkt 50) 02-807 Gasket Seal 02-816...
  • Page 22 ® logo and part number), and only in the specified configuration. Using incomplete or ® inappropriate equipment, including the use of counterfeit or non-RPB parts, can result in ® inadequate protection and will void the approval of the entire respirator assembly.
  • Page 23 AIR SUPPLY HOSES Figure 10.4 3. Supplied-Air Hose Series 1. Couplers 2. Plugs Assemblies 03-022-CF 04-322-25 RPB 7.5m RPB Quick 04-322-50 RPB 15m Connect 04-322-100 RPB 30m 50ft 100ft 25ft As detailed in column 3 of Figure 10.4...
  • Page 24: Warranty And Liability Statement

    Products, or the failure to properly maintain the Products. RPB’s limited warranty coverage runs from the original date of purchase of the Products, and ® applies only to warranted defects which first manifest themselves and are reported to RPB within ® the warranty period. RPB retains the right to determine to its reasonable satisfaction whether any ®...
  • Page 25: Nederlands

    SAFETY - EMEA ® T: +44-800-689-5031 E: sales@rpbsafety.co.uk rpbsafety.com Copyright ©2019 RPB Safety, LLC. Alle rechten voorbehouden. Alle inhoud op deze website is beschermd door de Amerikaanse auteursrechtwetgeving en mag niet worden gereproduceerd, gedistribueerd, overgedragen, weergegeven, gepubliceerd of uitgezonden zonder de voorafgaande schriftelijke toestemming van RPB Safety, LLC.
  • Page 26 De groen met grijze kleurencombinatie is een geregistreerd handelsmerk van RPB Safety, LLC. Alle rechten op het intellectuele eigendom van RPB in deze publicatie, inclusief auteursrecht, handelsmerken, dienstmerken, bedrijfsgeheimen en octrooirechten, zijn voorbehouden.
  • Page 27 Gebruik met een Ademlucht filter, zoals de 04-900 RPB RADEX Ademlucht Filter. ® ® Specifieke bescherming hangt af van de instelling van de Ademlucht filter (zie de RPB RADEX ® ® Gebruiksaanwijzing). Dit ademhalingstoestel is goedgekeurd met de 03-102 Regelaar.
  • Page 28 ASTRO ® DIAGRAM VAN ADEMHALINGSCOMPONENTEN Het RPB ASTRO Ademhalingstoestel bestaat uit drie hoofdcomponenten. Alle drie de ® ® componenten moeten aanwezig zijn en correct gemonteerd zijn om een compleet goedgekeurd Ademhalingstoestel met Ademlucht te vormen, conform EN 14594 en AS/NZS 1716.
  • Page 29 EN 12021 en AS/NZS 1715. De RPB ASTRO zuivert geen lucht en ® ® filtert geen verontreinigingen. Gebruik altijd een koolmonoxide-meter. Sluit de ademluchtslang van het ademhalingstoestel niet aan op stikstof, GEVAAR giftige gassen, inerte gassen of andere niet-adembare luchtbronnen. Controleer de luchtbron voordat u het masker gebruikt.
  • Page 30 Laat een gekwalificeerde arts of andere bevoegde zorgverlener medische evaluaties uitvoeren met behulp van een medische vragenlijst of een standaard medisch onderzoek.  Train medewerkers in het gebruik, onderhoud en de beperkingen van ASTRO ® Benoem een gekwalificeerd persoon met voldoende kennis over de RPB...
  • Page 31 Gebruik dit ademhalingstoestel niet totdat u deze handleiding en de Gebruiksaanwijzing van de regelaar heeft gelezen (extra exemplaren beschikbaar op rpbsafety.com/resources/) en getraind bent in het gebruik, het onderhoud en de beperkingen van het ademhalingstoestel door een gekwalificeerd persoon (benoemd door uw werkgever) die kennis heeft van het RPB ASTRO ademhalingstoestel.
  • Page 32 Raadpleeg Montage en Onderhoud van het Ademhalingstoestel (pagina 33). Zie Aantrekken (pagina 34) voor informatie over de pasvorm. CONTROLEER OF DE UITRUSTING GESCHIKT IS VOOR UW WERKZAAMHEID Controleer of de ASTRO de juiste bescherming biedt voor uw werkzaamheid. Controleer, indien van ®...
  • Page 33 ADEMLUCHTDRUKTABEL S - BIJZONDERE OF BELANGRIJKE AANWIJZINGEN VOOR DE GEBRUIKER - SAR TABEL 1.1 In deze tabel wordt het luchtdrukbereik vermeld dat nodig is om de RPB ASTRO te voorzien van ®...
  • Page 34 Opmerking: Controleer de slangaansluitingen op LET OP lucht lekt en zet vast indien nodig - vervang alle Zorg er altijd voor dat een RPB Veiligheid ® versleten onderdelen. Interne Ruit stevig in de venster pakking RUITEN is aangebracht.
  • Page 35 Als u deze stappen niet uitvoert, kunt u worden blootgesteld aan gevaarlijke materialen en verontreinigingen die het functioneren van het ademhalingstoestel nadelig kunnen beïnvloeden. DE KAP AANDOEN Nadat u klaar bent met de montage, bent u klaar om de RPB ASTRO aan te doen. Controleer ®...
  • Page 36 6.6 OP PAGINA 17 kap en uw werkkleding te reinigen voordat INSPECTIE, REINIGING EN DESINFECTIE Het ASTRO Ademhalingstoestel met ademlucht heeft een beperkte levensduur, daarom moet er regelmatig een inspectie- en vervangingsprogramma worden uitgevoerd. Bepaalde onderdelen zoals vizierruiten moeten vaak worden vervangen.
  • Page 37 VIZIEREN EN VIZIERPAKKINGEN Controleer de pakking van de interne ruit op spleten, scheuren of slijtage. Vervang beschadigde of versleten onderdelen onmiddellijk door originele RPB -onderdelen. De Pakking van de Interne ® Ruit kan worden schoongemaakt met warm water en een mild reinigingsmiddel, gespoeld en aan de lucht gedroogd.
  • Page 38 02-813 Nylon Cape ADEMHALINGSSLANG & REGELAARS AFBEELDING 10.3 OP PAGINA 21 Onderdeel Nummer Beschrijving NV2021B Breathing Tube 03-035 Breathing Tube Adaptor (to upgrade the ASTRO from the NV2021 to the ® NV2021B) NV2022 Belt 03-102 Constant Flow Valve ADEMLUCHTSLANGEN AFBEELDING 10.4 OP PAGINA 22...
  • Page 39 Producten. Deze beperkte garantie komt ten goede aan de oorspronkelijke koper van het Product en kan niet worden overgedragen of toegewezen. Dit is de enige en exclusieve garantie die door RPB ®...
  • Page 40 ™ Looking for an advanced climate control device that can heat and cool your supplied air just by the slide of a lever? Look no further than the RPB ® ™ From the searing heat of an Arizona summer to a severe Scandinavian...

Table of Contents