Honeywell U2 User Manual page 7

Combination viewing head and signal processors
Table of Contents

Advertisement

HONEYWELL U2 PROGRAMMING
INTERFACE TECHNIQUES:
TAP:
PRESS FINGER ON BUTTON AND REMOVE.
SCROLL:
PRESS FINGER ON GLASS AND MOVE FINGER IN CIRCLES (TWIRL).
RAMP: HOLD FINGER ON THE + OR - BUTTON.
FACTORY DEFAULT
FILE DEFAULT
ON
RS485
OFF
IRDA
PARITY
NONE
BAUD
ODD
EVEN
2400
4800
9600
19200
38400
57600
115200
PANEL LOCK
TIME OUT MIN
NOTE: If sensor is not available in your model, then no menu item will exist for sensor setting. See Table 1 on page 2 to
determine which sensors are active in your U2 model.
Temperature
Displays the processor temperature. Tapping enter will bring
the user into the submenu which will allow changes between
displaying Celsius or Fahrenheit, display the software version,
or display the number of hours the unit has been in operation.
Gain UVTron
NOTE: If sensor is not available in your model, then no
menu item will exist for sensor setting. See
Table 1 on page 2 to determine which sensors
are active in your U2 model.
Displays the Uvtron gain (adjustable 0-99). The default value
is 32.
Filter SSUV
NOTE: If sensor is not available in your model, then no menu item will exist for sensor setting. See Table 1 on page 2 to
determine which sensors are active in your U2 model.
Displays the current solid state UV high pass filter (adjustable 0-9). The default filter is 3. See the filter cutoff frequencies (in
Hertz) in the table below.
FILTER
0
1
HERTZ
9
16
4 SUB MENUS
HOURS
READ ONLY
WRITE ONLY
0->20 OR 4->20
ADDRESS-
A000
*F01
TD03
0000
RT01
0000
Fig. 2. User interface menu overview.
2
3
4
24
33
52
U2 COMBINATION VIEWING HEAD AND SIGNAL PROCESSORS
TWO BUTTON INTERFACE (BACK AND ENTER)
EVERYTHING ELSE CAN BE DONE BY SCROLLING
INTERFACE MODES:
FLAME DISPLAY: TAP BACK (MAY REQUIRE MORE THAN ONE TAP).
HELP:
LAST MENU:
ADJUST MODE: TAP ENTER FROM ADJUSTABLE MENU ITEM,
VERSION
NO YES MODE: CHANGE TO YES AND TAP STORE.
°F OR °C
DEFAULT
AUTO FILTER
AUTO GAIN
3425
COMMS
BACK
PANEL
HELP
FILE
ENTER
STORE
TIME DELAY-
LAST MENU
FFRT-
FLAME OFF-
0600
Gain SSUV
NOTE: If sensor is not available in your model, then no
menu item will exist for sensor setting. See
Table 1 on page 2 to determine which sensors
are active in your U2 model.
Displays the solid state UV gain (adjustable 0-99) The default
value is 75.
Gain IR
NOTE: If sensor is not available in your model, then no
menu item will exist for sensor setting. See
Table 1 on page 2 to determine which sensors
are active in your U2 model.
Displays the IR gain (adjustable 0-99). The default value is 75.
5
6
7
75
100
155
7
TAP + OR - (FROM DISPLAY).
TAP ENTER,
MOVE THROUGH MENU WITH TAPS OR SCROLLS.
CHANGE VALUE USING ANY TECHNIQUE.
127 °F
GT32
GAIN TUBE UV -
G 32
GAIN SS UV-
FILTER SS UV-
HELP
GAIN IR-
FILTER IR-
GAIN MA OUT-
GM32
FLAME ON-
0800
8
9
215
300
F 09
GI32
FI04
M33314
66-2071—02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents