Sec. II Filling Tank with Hydrocolloid Paste
1. PLUG IN MAIN POWER TO A GROUNDED OUTLET.
2. Turn unit on by pressing the red switch to "I". Wait approx 15-20
minutes for the unit to heat up. The Temperature Controller will read
approx PV 130 (top numbers in white) and SV 130 (bottom numbers
in green).
3. Fill tank with chunks of Hydrocolloid Paste (no larger than 1 inch
chunks) to rim of tank, gently pack down and re-fill to rim again.
Note:
If you do not add approximately 1 cup of water to re-melts, paste
.
may be lumpy
FIG 5
Using the handles carefully and
gently place lid (with mixer) back on
the unit, ensure that the lid is all the
way down and locks into the Mixer
Locking Pins.
FIG 6
Sec. III Melt Down Process
If at any time an error is made during set up of melt down, simply
press
.
Note:
Fill tank with hydrocolloid paste. Refer to Sec II above.
1. Plug Mixer Unit into the Power Plug located at the back of unit.
2. Press SEL (hold down for approx. 2 seconds) and "PROG OFF" will be
displayed.
FIG 7a
3. Press SEL again and OFF will flash.
4. Press UP ARROW once and RUN will flash.
5. Press SEL and PROG RUN will be displayed.
The unit is now in the melt down cycle
After approx 1-2 minutes PV will display the actual temperature in the
unit and SV will display the ramp up temperatures as the unit heats up
(which will eventually be 194°F within 20 minutes). After approximately
10 -15 minutes these temperatures will be close to mirroring each other.
FIG 7e
Note:
The unit may reach a slightly higher temperature than 194°F
during this melt down for a short period of time. Melt down time is set
for 1 hour and 10 minutes, the mixer will turn on and off constantly.
6. After the melt down cycle is complete, the SV (green numbers) will
drop to 130 and the PV (white numbers) will indicate the actual
temperature of the paste. When the SV and PV both read 130, the
paste is ready for use. This cool down time is approx 2 hrs.
tcs®
We suggest melting down at the end of the work day so that the paste
is ready for use in the morning.
Duplicating
Sec. IV Ready to Use
Unit
When the SV and PV both read 130°F, the paste is ready for use.
7. Dispensing the paste: Slightly pull up on the Dispensing Handle while
Model #3611-01
slowly pulling outward at the same time. Material will begin to flow out.
FIG 8
8. Stop flow by pushing the Dispensing Handle back and locking in.
FIG 7e
Temperature Controller
~190
nufactured in the U.S.A.
~194
tcs®
3 Copyright 2019 Thermoplastic Comfort Systems, Inc.
Operation Instructions: TCS Duplicating Unit Model TC105
FIG 6
FIG 7b
FIG 7c
FIG 7d
tcs®
Duplicating
Unit
Model #3611-01
FIG 7f
PV
SV
I
tcs®
0
FIG 3
FIG 3
FIG 4
tcs®
FIG 5
Duplicating
Unit
A .
S .
U .
e
t h
i n
d
r e
t u
a c
u f
n
M
a
Model #3611-01
FIG 7
Antifreeze Indicator
should be half full.
A .
S .
U .
e
t h
i n
FIG 7a
tcs®
Duplicating
Unit
Model #3611-01
tcs®
FIG 7c
FIG 7f
Manufactured in the U.S.A.
FIG 9
tcs®
FIG 8
Temperature Controller
130
PV
130
SV
I
0
FIG 4
A .
S .
U .
e
t h
i n
d
r e
t u
a c
u f
n
a
M
FIG 7
tcs®
Add
1 cup
of water to
Duplicating
re-melts
Unit
Model #3611-01
d
r e
t u
a c
u f
n
a
M
Temperature Controller
FIG 7b
tcs®
ProG
PV
Duplicating
oFF
Unit
SV
Model #3611-01
I
tcs®
0
Press SEL
Keep Pressed until
"PROG OFF" is displayed
tcs®
Temperature Controller
FIG 7d
Duplicating
Unit
ProG
PV
rUn
Flash
SV
Model #3611-01
I
0
tcs®
Press UP arrow
tcs® DUPLICATING UNIT
tcs® DUPLICATING UNIT
"rUN" will ash
Warnings
Warnings
Temperature Controller
• Read Instructional Manual prior to use.
• Read Instructional Manual prior to use.
• DO NOT plug in unit without adding 100% PURE ANTIFREEZE.
• DO NOT plug in unit without adding 100% PURE ANTIFREEZE.
Do not substitute antifreeze.
Do not substitute antifreeze.
• Maintain antifreeze level
• Maintain antifreeze level
(approx half full according to glass indicator on side of unit).
(approx half full according to glass indicator on side of unit).
• When filling the unit with Duplicating Paste unplug the motor from
• When filling the unit with Duplicating Paste unplug the motor from
the control box.
the control box.
• Replug motor to control box after lid is securely on unit.
• Replug motor to control box after lid is securely on unit.
• Ready for use when red light temperature reads 130 degrees.
• Ready for use when red light temperature reads 130 degrees.
• This unit is designed to be left ON at all times.
• This unit is designed to be left ON at all times.
FIG 9
C A U T I O N
C A U T I O N
H O T S U R F A C E
H O T S U R F A C E
PV
130
Manufactured in the U.S.A.
SV
130
SEL ^
Pull up and outward
I
0
www.tcsdentalinc.com / 866-426-2970
I112012 Rev D
Effective Date: 11/12/19
Hydrocolloid
Paste Chunks
Antifreeze Indicator
should be half full.
A .
S .
U .
e
t h
i n
d
r e
t u
a c
u f
n
a
M
A .
S .
U .
t h
e
i n
d
r e
t u
a c
u f
n
a
M
Temperature Controller
ProG
PV
oFF
SV
Flash
I
0
Press SEL again
without keeping
"oFF" will ash
tcs®
Temperature Controller
Duplicating
Unit
ProG
PV
rUn
SV
Model #3611-01
I
0
tcs® DUPLICATING UNIT
tcs® DUPLICATING UNIT
Press SEL one time and
Warnings
Warnings
Temperature Contro
"PROG" "rUN" will appear
• Read Instructional Manual prior to use.
• Read Instructional Manual prior to use.
• DO NOT plug in unit without adding 100% PURE ANTIFREEZE.
• DO NOT plug in unit without adding 100% PURE ANTIFREEZE.
Do not substitute antifreeze.
Do not substitute antifreeze.
• Maintain antifreeze level
• Maintain antifreeze level
(approx half full according to glass indicator on side of unit).
(approx half full according to glass indicator on side of unit).
• When lling the unit with Duplicating Paste unplug the motor from
• When lling the unit with Duplicating Paste unplug the motor from
the control box.
the control box.
• Replug motor to control box after lid is securely on unit.
• Replug motor to control box after lid is securely on unit.
• Ready for use when red light temperature reads 130 degrees.
• Ready for use when red light temperature reads 130 degrees.
• This unit is designed to be left ON at all times.
• This unit is designed to be left ON at all times.
C A U T I O N
C A U T I O N
130
H O T S U R F A C E
H O T S U R F A C E
Manufactured in the U.S.A.
SEL
^
Push in
and down
to lock
PV
130
SV
<
^
^
I
0

Advertisement