Download Print this page

TCS TC105 Operating Instructions page 2

Duplicating unit - 2 gallon

Advertisement

2. Unpacking and Safety
Your safety and the safety of others are important. We have provided important safety messages in this manual. Please read these messages
carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert
symbol. The definition of these symbols are described below:
Ventilation Clearance:
Back of the instrument
Sides of the instrument
3. First Time Use
Before Plugging in Unit
Sec. I Filling the Unit with Antifreeze
1. Disconnect Mixer Power Plug from the back of the unit and remove
lid (with mixer) by lifting straight up by the 2 handles. Set lid carefully
on its side.
FIG 1
2. DO NOT lift lid from Mixer Motor.
3. Place a funnel into Antifreeze Intake Pipe located at the back of unit.
Pour in 100% pure antifreeze, the unit will take almost the entire
gallon of antifreeze that was included with the unit. Check antifreeze
indicator on the side of unit to ensure that it is half full.
IMPORTANT: 100% Pure Antifreeze must be used. Do not
substitute antifreeze. In case too much antifreeze is poured in, it
will overflow from the Intake Pipe.
Note:
Always maintain level of antifreeze at half full according to
Antifreeze Indicator.
FIG 2
Depending on use and other variables, more antifreeze will have to be
added a few times per year.
4. With a damp cloth clean inside of unit and remove any antifreeze
fluid that may have poured in.
2 Copyright 2019 Thermoplastic Comfort Systems, Inc.
Operation Instructions: TCS Duplicating Unit Model TC105
General Safety Hazard: Refer to the instructions for details on the specific hazard.
Caution: Hot surface warning
Caution: Electrical shock hazard
Technical Symbol: All operations marked with this symbol are to be performed by qualified maintenance
personnel only.
AREA
Above
Below
Warning: DO NOT PLUG IN unit until filled with 100% pure antifreeze.
Caution: High voltages are present. The line power connections must have a functioning ground connection
and over voltage protection in the form of a fuse or circuit breaker.
** DO NOT DEFEAT THE GROUND WIRE ON POWER PLUG
** TURN OFF INJECTOR BEFORE DISCONNECTION OR CONNECTING ELECTRICAL PLUGS
FIG 1a & 1b
FIG 2
MINIMUM REQUIRED CLEARANCE
10 cm / 4 inches
20 cm / 8 inches
30 cm / 12 inches
FIG 1
A .
S .
U .
e
t h
i n
d
r e
t u
a c
u f
n
a
M
FIG 2
ANTIFREEZE
Antifreeze Indicator
should be half full.
.
A
.
. S
U
e
h
t
i n
d
r e
u
c t
f a
u
n
a
M
N/A
FIG 1a
FIG 1b
A .
S .
U .
t h
e
i n
d
r e
t u
a c
u f
n
a
M
A .
S .
U .
e
h
i n
t
d
r e
u
c t
u f
a
n
a
M
www.tcsdentalinc.com / 866-426-2970
I112012 Rev D
Effective Date: 11/12/19

Advertisement

loading