Download Print this page

TCS TC105 Operating Instructions

Duplicating unit - 2 gallon

Advertisement

Quick Links

TCS Duplicating Unit - 2 gallon
Operating Instructions
tcs®
Duplicating
Unit
Model #3611-01
tcs® DUPLICATING UNIT
Warnings
• Read Instructional Manual prior to use.
• DO NOT plug in unit without adding 100% PURE ANTIFREEZE.
Do not substitute antifreeze.
• Maintain antifreeze level
(approx half full according to glass indicator on side of unit).
• When lling the unit with Duplicating Paste unplug the motor from
the control box.
• Replug motor to control box after lid is securely on unit.
• Ready for use when red light temperature reads 130 degrees.
• This unit is designed to be left ON at all times.
C A U T I O N
PV
H O T S U R F A C E
Manufactured in the U.S.A.
SV
SEL
<
^
^
I
tcs®
0
DO NOT PLUG IN
antifreeze immediately burns the heating element and voids the warranty.
1. Get to Know Your Machine
A
tcs®
Duplicating
Unit
Model #3611-01
B
B
C
H
tcs® DUPLICATING UNIT
Warnings
• Read Instructional Manual prior to use.
• DO NOT plug in unit without adding 100% PURE ANTIFREEZE.
Do not substitute antifreeze.
• Maintain antifreeze level
(approx half full according to glass indicator on side of unit).
• When lling the unit with Duplicating Paste unplug the motor from
the control box.
• Replug motor to control box after lid is securely on unit.
• Ready for use when red light temperature reads 130 degrees.
• This unit is designed to be left ON at all times.
C A U T I O N
H O T S U R F A C E
Manufactured in the U.S.A.
F
tcs®
G
WARNING: DO NOT PLUG IN UNIT UNTIL FILLED WITH 100% PURE ANTIFREEZE. MAINTAIN ANTIFREEZE
Important things to know about your machine:
• This unit is pre-calibrated as follows: Once the program cycle is set to "run" (refer to instruction) and the melt down begins it will take 20 minutes to reach
its calibrated high temperature of 194°F. The unit will remain at the high temperature for 1 hour and 10 minutes as it melts the paste. The unit will then
automatically begin to cool to the holding temperature of 130°F, this will take approximately 2 hours. It will remain at this temperature at all times until all
the paste is used and you are ready to run a new cycle.
• This unit is designed to be "on" at all times.
• At the beginning of the melt down cycle the mixer will make very slight turning movements, however, as the paste begins to melt, the mixer will turn
faster. The mixer is designed to turn periodically in small increments once it is at holding temperature. The double boiler protects the paste from burning.
• If the default parameters are not working for your type of paste, e.g. lumpy paste, refer to FAQ to change parameters or contact TCS Inc. for assistance.
• Always add approximately one cup of water to each re-melt down to avoid lumpy paste.
1 Copyright 2019 Thermoplastic Comfort Systems, Inc.
Operation Instructions: TCS Duplicating Unit Model TC105
The TCS Duplicating Unit uses antifreeze
in a double boiler design. This engineering
spares the
hydrocolloid
sticking to the sides of the tank and
burning. This unit is meant to be kept "on"
at all times so that you have paste ready
when you need it.
Item #3614-01 (110V)
please read manual prior to use
**W A R N I N G**
until filled with 100% pure Antifreeze. Running the unit without
FRONT VIEW
A. Mixer motor
B. Handles
C
C. Mixer locking pins
D. Temperature controller
E. On/off button
D
ProG
PV
F. Dispensing handle
rUn
SV
G. Drip plate
I
E
0
H. Antifreeze indicator
SPECIFICATIONS
Capacity: 2 gallons
Weight: 20 lbs | 9 kilos
Dimensions: Width 14-1/4'" | Height 21" | Tank diameter 10"
Dimensions: 110V
LEVEL APPROX. 1/2 FULL ACCORDING TO ANTIFREEZE INDICATOR.
paste
from
J
K
L
Model TC105
BACK VIEW
I. Antifreeze intake pipe
J. Fuse
K. Mixer power cord 110V
I
L. Unit power plug
A .
S .
U .
e
t h
i n
d
r e
t u
a c
u f
n
a
M
www.tcsdentalinc.com / 866-426-2970
I112012 Rev D
Effective Date: 11/12/19

Advertisement

loading

Summary of Contents for TCS TC105

  • Page 1 The mixer is designed to turn periodically in small increments once it is at holding temperature. The double boiler protects the paste from burning. • If the default parameters are not working for your type of paste, e.g. lumpy paste, refer to FAQ to change parameters or contact TCS Inc. for assistance.
  • Page 2 4. With a damp cloth clean inside of unit and remove any antifreeze fluid that may have poured in. Antifreeze Indicator should be half full. www.tcsdentalinc.com / 866-426-2970 2 Copyright 2019 Thermoplastic Comfort Systems, Inc. I112012 Rev D Operation Instructions: TCS Duplicating Unit Model TC105 Effective Date: 11/12/19...
  • Page 3 Pull up and outward nufactured in the U.S.A. ~194 Push in and down to lock tcs® tcs® www.tcsdentalinc.com / 866-426-2970 3 Copyright 2019 Thermoplastic Comfort Systems, Inc. I112012 Rev D Operation Instructions: TCS Duplicating Unit Model TC105 Effective Date: 11/12/19...
  • Page 4 The temperature has been changed, your next melt down will use this new parameter. www.tcsdentalinc.com / 866-426-2970 4 Copyright 2019 Thermoplastic Comfort Systems, Inc. I112012 Rev D Operation Instructions: TCS Duplicating Unit Model TC105 Effective Date: 11/12/19...