INTRODUCTION:
GENERAL:
Thank you for purchasing your Fairbanks Nijhuis
please read the following manual carefully.
BEFORE OPERATION. Read the following in structions care ful ly. Reasonable care and safe meth ods should be practiced. Check
local codes and requirements before installation.
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or
other reproductive harm.
ATTENTION: This manual contains important information for the safe use of this product. Read this manual completely
before using this product and refer to it often for con tin ued safe product use. DO NOT THROW AWAY OR LOSE THIS
MAN U AL. Keep it in a safe place so that you may refer to it often.
UNPACKING PANEL. Remove panel from carton. When un pack ing unit, check for concealed damage. Claims for damage must be
made at the receiving end through the delivery carrier. Damage cannot be processed from the factory.

POWER SUPPLY:

Do not attempt to wire this control box unless you have a good working knowledge of electricity and are familiar with the
state and local codes. If you are in doubt about anything, contact a qualified electrician.
Do not attempt to operate this unit on any other voltage or power distribution other than for which it was originally
designed (check nameplate). Failure to comply with this will result in the immediate cancellation of all warranties
and claims.
It is advisable to put the panel on its own circuit using a circuit breaker adequately sized to protect the mixer. Check state and local
codes for the correct wire size and circuit protection to use. The wire should be sized large enough to handle the full load current of
the mixer you are operating and any voltage drop that might occur due to long service runs.
Run power supply lines to the control box and secure (knockouts are not supplied in this box). Select a convenient location on the
bottom to enter the box with the power supply. Cut a hole with a chassis punch. Caution should be taken not to get metal chips in
the components while cutting hole. After the hole is cut, any metal particles must be removed from the box. Failure to do so may
result in premature component failure.
Connect incoming power to the terminal blocks per the included schematic and all necessary ground wires to the ground lug at the
bottom right of the box. The ground lug should be fastened to a good driven earth ground by one of the methods described in the
National Electric Code. NEC does not permit using ground as a current-carrying conductor, therefore a neutral must be provided for
115 volt 1 phase, 208 volt 1 phase, 230 volt 1 phase, or 208 volt 3 phase systems.
Before handling these mixers and controls, always disconnect the power first. Do not smoke or use sparkable electrical
devices or flames in a septic (gaseous) or possible septic sump.
ELECTRICAL CONNECTIONS: The contractor must conform to the latest requirements of the National Electrical Code. All conduit
and ca bles shall be in accordance with NEC Code NFPA #70. To maintain UL and CSA ENCL rating, use the same type UL and
CSA weatherproof con duit hubs when connecting to this en clo sure. Prior to conducting any in stal la tion, repair or service with
re gard to the control panel, refer to the schematic appropriate for that panel. The schematic will provide guidance with regard to the
terminal block con nec tions.
A nonmetallic enclosure does not provide grounding conduit con nec tions. Use grounding bush ing and jumper wires.
MAKE THE FOLLOWING ELECTRICAL CON NEC TIONS:
a. Connect the mixer leads to the control panel.
b. Connect the mixer heat sensor and seal failure leads (if available on the mixer) to the appropriate ter mi nal blocks in the
control panel.
c. Before connecting power to the control panel, make sure all con trol switches (e.g. H-O-A switch) and protective devices (e.g.
breakers) are in the Off po si tion. Now connect power to the terminal block or the circuit break er as directed by the sche mat ic.
d. Control panel must be grounded properly per NEC and/or local codes. To facilitate this, a ground lug is provided on the
control panel.
®
Basin Mixer Control Panel. To help ensure years of trouble-free operation,

CALIFORNIA PROPOSITION 65 WARNING:

WARNING:
WARNING:
CAUTION:
FBM(X)20 Basin Mixer Control Panel
Instruction and Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fairbanks nujhuis fbmx20

Table of Contents