Saivod TMS307 Instructions Manual page 30

Table of Contents

Advertisement

Available languages

Available languages

SECURITY CHARACTERISTICS
 Security Valve: This electric water heater fits a mono-directional security valve. It must be installed
at the water entering hole sector of this unit of the electric water heater. When the tank's pressure
is over 0.8MPa, this valve will automatically leak the pressure. It may exist the water drops to fall
down at the pressure leakage mouth sector. In any conditions, this pressure leakage mouth must
not to be blocked. You must keep it anti-through with the atmosphere.( Diagram 1)
Note: For the interior-ventilating styled security valve, its pressure leakage exit sector may not exits
the water drops to drip down. Otherwise, during the heating procedure, the water-entering pipe's outer
cover under the safety valve may have a certain temperature. This belongs to the normal conditions. This
indicates that it is internally-draining the leakage pressure.
 To drain the tank perform the following steps :
If needing to make the tank empty, firstly close the water-entering valve door, open the water-exiting
valve door. Then tear down the fixed screw nails on the security valve with tools. Make the plastic handle
lift up; let the water in the tank naturally flow out.
(Diagram 2)
TECHNICAL REFERENCE DATA
RATED VOLTAGE
RATED FREQUENCY
RATED PRESSURE
RATED WATER TEMPERATURE
WATER-PROOF DEGREE
FITTED SOCKET
30
water heater.indd 30
Diagram 1
Diagram 2
220-240V~
RATED POWER
50/60HZ
RATED CURRENT
0.75MPA
RATED VOLUME
75°C
IPX4
STRUCTURE MODE
250V~,10A
FIXING MODE
1500W
6.5A
30L, 50L,80L
HERMETICALLY
CLOSED TYPED
WATER STORAGE
STYLE
HANGING TYPE
3/1/2017 4:42:43 PM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tms507Tms807

Table of Contents