32
User Wave Data
This is the actual wave that is sent along with each wave parameter.
System Exclusive Format
Field
Value
01
SYSEX
F0
02
MAN
44
03
MOD
11,02
dev
04
Either 00 to 1F, or 7F
act
05
04(HDS), 05(HDR), 07(Control)
cat
06
Wave Data = 08
prm
07
00-7F
ilen/dlen See "IV This Model's System Exclusive Messages".
08
ps
09
Indicates the wave number being transferred.
For details, see "40 About Parameter Set (PS) numbers".
index
10
See "IV This Model's System Exclusive Messages".
data
11
See "IV This Model's System Exclusive Messages".
sum
12
See "IV This Model's System Exclusive Messages".
13
EOX
F7
33
User DSP Parameter Set
System Exclusive Format
Field
Value
01
SYSEX
F0
02
MAN
44
03
MOD
11,02
dev
04
Either 00 to 1F, or 7F
act
05
04(HDS), 05(HDR), 07(Control)
cat
06
DSP = 09
prm
07
00-7F
ilen/dlen See "IV This Model's System Exclusive Messages".
08
ps
09
Indicates the DSP number being transferred.
For details, see "40 About Parameter Set (PS) numbers".
index
10
See "IV This Model's System Exclusive Messages".
data
11
See "IV This Model's System Exclusive Messages".
sum
12
See "IV This Model's System Exclusive Messages".
13
EOX
F7
63