3. MOUNTING INSTALLATION
3.1
WALL MOUNTING (see fig.1)
IMPORTANT! The following points should be noted: The heater should always have a
minimum clearance of 450mm from a ceiling and be at least 1M (CH-1500) or 1.5M (CH-
3000) from any object (see table on front page).
IMPORTANT! Ensure that the mounting surface is capable of supporting the weight of the
heater.
IMPORTANT! The heater should be mounted at 30º to 45º from the vertical.
IMPORTANT! The mounting bracket must be sufficiently earthed.
3.2
Remove the wall mounting bracket from the box.
Place heater face down and attach one 'U' bracket to back. Make sure cable gland is towards
3.3
the bottom of the heater.
Diagram A
This Small Spacer
Must Be Used
3.4
Decide whether vertical movement only (Diagram A) or vertical / horizontal movement
(Diagram B) is required for correct positioning of heaters and assemble as shown.
3.5
Before drilling, ensure that there are no wires or water pipes in the area where the heater is to
be placed.
3.6
Use the bracket as a template. Fix the metal bracket to the wall by means of the three holes and appropriate fixings (not supplied).
3.7
Refit the heater onto the bracket making sure mains cable is at the bottom with the bolt and spacers provided.
3.8
Adjust the angle of heater to direct heat where required, ensuring the heater is between 30° and 45° from the vertical.
4. ELECTRICAL CONNECTIONS
4.1
230V INSTALATION
4.2
Please make sure you have read the Safety instructions and you are a suitably qualified electrician before continuing.
4.3
This heaters is factory fitted with high temperature silicon rubber flexible cable conforming to BS 6500 having a temperature rating of 180°C. If
necessary only replace with the same specification / temprature rating cable.
4.4
Heaters must be earthed.
4.5
Connection to a Switched Fused Spur / Isolator.
a) Connect the GREEN/YELLOW earth wire to the
earth connection.
b) Connect the BROWN live wire to the live
connection.
c) Connect the BLUE neutral wire to the neutral
connection.
d) After wiring, check that there are no bare wires,
that all wires have been correctly connected, that
the cable outer insulation extends beyond the
cable restraints and that the restraint is tight.
5. COMMISSIONING
Note: The Heater runs hot so please wait till it has cooled down before moving / adjusting.
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.
5.1
Perform Insulation and Earth continuity tests.
5.2
Switch on the heater(s) and confirm that the Ceramic element(s) are working.
5.3
Ensure each heater aims its warmth into the target area by adjusting the heater angle(s) as required, and then tighten the bracket bolts keeping the
heater(s) firmly in place while doing so.
5.4
Make sure you maintain an angle between 30º & 45º in the vertical plane.
5.5
The user / customer should be made aware of all aspects of the operation and safety advice. Keep the instructions safely for future reference.
5.6
In unoccupied premises it is recommended that the heating system is switched of and isolated from the electrical supply.
6. MAINTENANCE
Note: Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply.
6.1
Ceramic Heaters contain no moving parts and therefore very little maintenance is required other than to ensure that there is no excessive build-up of
dust / dirt on the reflectors or Ceramic elements especially after a long period of non-use as this can cause overheating and premature ceramic failure.
Depending on installation conditions the heater should be regularly inspected, but at least once per year.
Spare Ceramic elements and reflectors are available contact your supplier for details
This product conforms to EU Directive 2002/96/EC.
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as domestic
waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's responsibility to dispose of this appliance
through the appropriate channels. Failure to do so may incur penalties established by laws governing waste disposal.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data,
specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Your BN Thermic product is guaranteed for one year from date of purchase. We will repair or
replace at our discretion any part found to be defective. We cannot assume any consequential liability. This
guarantee in no way prejudices your rights under common law and is offered as an addition to consumer
liability rights.
REGISTER: Activate your warranty by registering online at www.bnthermic.co.uk and retain this installation
data for future reference.
Wall Mounted
Vertical Movement
Only
Wall Mounted Vertical
and Horizontal
Movement
1 Phase Supply
Diagram B
Switched Fused
Spur / Isolator
220 – 240V
For Recommended
Mounting Heights See
Table on Front Page
Green / Yellow
Blue
Brown
BN Thermic Ltd,
34 Stephenson Way, Three Bridges,
Crawley, RH10 1TN
Tel: +44 (0) 1293 547361
Email: sales@bnthermic.co.uk
Web: www.bnthermic.co.uk