Pilot Valves; Pilot Valve Repair Kit; Differential Setting Chart - Quincy Air Master QT Series Parts Manual

Table of Contents

Advertisement

110832 Series Pilot Valve (continuous run operation)
Add dash # listed below to 110832 (per pressure setting) to
obtain correct pilot valve.
Dash #
Load PSI
-100
-997
-998
-999
* Customer to set, see differential setting chart. Additional
factory preset valves are available upon request.

Pilot Valve Repair Kit 110832-051

Can be used to repair 110832 series pilot valves only. Cus-
tomer must specify which spring when ordering repair kit.
Item
Part
#
Qty.
Number
1
2
2
1
3
1
4
1 see chart below
5
1

Differential Setting Chart

Spring Part #
Unload
(item 4)
(p.s.i.)
110832-052 (red)
30
"
40
"
50
"
60
"
70
110832-053 (yellow) 80
"
90
"
100
"
110
"
120
"
130
"
140
"
150
110832-054 (green) 160
"
170
"
175
QT-7.5 Air Master
50121M201, May 2001
Unload PSI
90
100
*
30-70 adjustable
*
71-150 adjustable
*
151-175 adjustable
Description
screen
filter
"o"ring
pilot valve spring
ball
Min. Dif.
Max. Dif.
(p.s.i.)
(p.s.i.)
2
4
5
8
5
8
5
8
5
10
5
10
5
12
5
13
5
15
5
15
5
18
5
18
5
20
5
15
5
20
5
23
110998 Series Pilot Valve (dual control operation)
Add dash # listed below to 110998 (per pressure setting) to
obtain correct pilot valve.
Dash #
-115
-140
-165
Differential Setting Chart
Applies to 110998 series pilot valves only.
Unload
(p.s.i.)
40
60
100
150
175
WARNING !
Not all pilots are for use with all compressor systems. Make
sure that the pilot you order is set within the safe operating
limits of your compressor. Failure to heed this warning
could result in an explosion.
14
3501 Wismann Lane, Quincy IL 62305-3116

PILOT VALVES

Load PSI
Unload PSI
100
115
125
140
150
165
Min. Dif.
Max. Dif.
(p.s.i.)
(p.s.i.)
2
5
3
10
4
20
5
30
5
45
Quincy Compressor