Quincy QTS Series Instruction Manual

Industrial

Advertisement

® ® ® ® ®
Q T S
Q T S
Q T S
Industrial Series
Industrial Series
Industrial Series
Q T S
Q T S
Industrial Series
Industrial Series
This manual contains important safety information and must be
carefully read in its entirety and understood prior to installation by
all personnel who install, operate and/or maintain this product.
Instruction Manual
Manual No. 50263-106
October 2004 Edition

Advertisement

Table of Contents
loading

Summary of Contents for Quincy QTS Series

  • Page 1 ® ® ® ® ® Q T S Q T S Q T S Industrial Series Industrial Series Industrial Series Q T S Q T S Industrial Series Industrial Series Instruction Manual This manual contains important safety information and must be carefully read in its entirety and understood prior to installation by all personnel who install, operate and/or maintain this product.
  • Page 2: Table Of Contents

    What does this warranty cover? Quincy Compressor (the Company) warrants this compressor to be free from defects in materials and workmanship for a period of one year from date of purchase. Vacuum pumps used in natural gas applications are warranted for a 90 day service period.
  • Page 3: Description & Application

    & APPLICATION •Do not change the pressure setting of the pressure Industrial & Air Master QTS Series single stage relief valve, restrict the function of the pressure compressors and vacuum pumps are air-cooled and relief valve, or replace the pressure relief valve splash lubricated.
  • Page 4 Fig.s 1 thru 4 are for two cylinder single stage units only CAUTION ! Verify all wires are secure and fasteners are torqued before connecting power to the unit. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 5 Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 6 Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 7 Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 8 Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 9 Mounting Stationary Units cian. Proper mounting of Quincy compressor units is cru- cial to the safe operation and longevity of the equip- Stationary Industrial & Air Master Series (2 & 4 ment.
  • Page 10: System Components

    When the demand is satisfied, the unit stops. Pressure switches pro- WARNING ! vided by Quincy Compressor are preset at the factory Guards must be fastened in place before starting and should only be modified by a qualified techni- the compressor.
  • Page 11 A clean, cool, dry, non-pressurized air supply is The manual tank drain valve on portable compres- essential to the satisfactory operation of your Quincy sors and some stationary compressors is located on compressor. A condensate trap must be installed as the underside of the air tank.
  • Page 12: Pre-Starting Checklist

    Never assume a compressor is safe to work on just because it is not operating. It could restart at any time. Follow all safety precautions outlined in MAIN- TENANCE. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 13: Maintenance

    (capscrews). To ensure optimal perfor- proximately 80 PSI of air pressure in the mance, Quincy recommends that you initially oper- tank for 1 hour to break-in (use tank drain or ate the compressor for at least one hour. Then shut regulator to control tank pressure).
  • Page 14 • Check belt tension. An in-line filter or dryer, available from your local Quincy distributor, may be required to eliminate the • Check flywheel retaining screws. moisture. Every 6 Months (or every 500* hrs.) Condensation in the air tank can be kept to a •...
  • Page 15 Refer to Fig. 15. To adjust the belt tension, loosen the 4 motor mounting screws and slide the motor in the proper direction. Retighten the motor mounting screws. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 16: Pilot Valve Adjustments

    Step Step 5. Loosen locknut (counterclockwise). * Stabilize with back-up wrench! Step 7. Tighten locknut (clockwise) with wrench. * Stabilize with back- up wrench! Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 17: Decal Locations

    DECAL LOCATIONS Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 18 TYPICAL DECAL LOCATIONS FOR VERTICAL UNITS (model QT-5 vertical unit shown) Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 19: Troubleshooting

    Replace motor. Defective motor. Change power cord & voltage Motor voltage does not match of motor to match voltage of voltage of power source. power source. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 20 Compressor unit bolted to Alignment & Adjustment). uneven surface or not bolted down at all (stationary Shim to level surface & fasten models). to floor if possible. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 21 Turn unit off, unplug it, & when compressor shuts off. tank drain valve, tubing, tighten or replace fittings or fitting or hose). components. Faulty check valve. Replace faulty check valve. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 22 Take to authorized service Restriction in head or check center. valve. Take to authorized service center. Take to authorized service center. Inspect, clean or replace. Industrial Series Quincy Compressor 50263-106, October 2004 3501 Wisman Lane, Quincy IL - 62305-3116...
  • Page 23 ENVIROMENTAL AND OSHA REQUIREMENTS: At the time of ship- in transportation or procuring materials, or causes of any kind beyond Seller’s ment of the equipment from the factory, Quincy Compressor / Ortman Fluid control. No provision for liquidated damages for any cause shall apply under Power will comply with the various Federal, State and local laws and this order.
  • Page 26 Recipr Recipr Recipr Recipr Reciprocating / Systems: ocating / Systems: ocating / Systems: ocating / Systems: ocating / Systems: 217.222.7700 Air Master Air Master Air Master 217.277.0270 Air Master Air Master E-mail: E-mail: E-mail: E-mail: E-mail: info@quincycompressor.com Website: Website: Website: Website: Website: quincycompressor.com...

Table of Contents