www.aeg.com
Problem
An acoustic signal sounds
and the hob deactivates.
An acoustic signal sounds
when the hob is deactivated.
The hob deactivates.
Residual heat indicator does
not come on.
Hob²Hood does not work.
Automatic Heat Up does not
operate.
The heat setting changes
between two levels.
The sensor fields become
hot.
Possible cause
The fuse is blown.
You do not set the heat set‐
ting for 10 seconds.
You touched 2 or more sen‐
sor fields at the same time.
Pause operates.
There is water or fat stains
on the control panel.
You put something on one or
more sensor fields.
You put something on the
sensor field
.
The zone is not hot because
it operated only for a short
time or the sensor is dam‐
aged.
You covered the control pan‐
el.
You use a very tall pot which
blocks the signal.
The zone is hot.
The highest heat setting is
set.
Power management oper‐
ates.
The cookware is too large or
you put it too near to the
controls.
Remedy
Make sure that the fuse is
the cause of the malfunction.
If the fuse is blown again
and again, contact a quali‐
fied electrician.
Activate the hob again and
set the heat setting in less
than 10 seconds.
Touch only one sensor field.
Refer to "Daily use".
Clean the control panel.
Remove the object from the
sensor fields.
Remove the object from the
sensor field.
If the zone operated suffi‐
ciently long to be hot, speak
to an Authorised Service
Centre.
Remove the object from the
control panel.
Use a smaller pot, change
the cooking zone or operate
the hood manually.
Let the zone become suffi‐
ciently cool.
The highest heat setting has
the same power as the func‐
tion.
Refer to "Daily use".
Put large cookware on the
rear zones, if possible.