In Canada, the installation of this range must conform with the
current standards CAN/CSA-Z240.1, latest edition, or with local
codes.
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood
combination above the cooking surface, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
A. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61.0 cm]
minimum clearance if bottom of wood or metal cabinet is covered by
not less than 1 /4" [6.4 mm] flame-retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015" [0.4 mm] stainless
steel, 0.024" [0.06 cm] aluminum, or 0.020" [0.5 mm] copper)
D. 13" (33.0 cm) recommended upper cabinet depth
E. 2
1
/
" (5.4 cm)
8
F.
19
15
/
" (50.6 cm)
16
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet: 12" (30.5 cm) minimum from bottom of
countertop
I.
Junction box or outlet: 10" (25.4 cm) from right-hand side of cabinet
J.
28
5
/
" (72.7 cm) on 30" (76.2 cm) models
8
34
3
/
" (88.3 cm) on 36" (91.4 cm) models
4
K. 6" (15.2 cm) minimum distance to nearest left and right side
combustible surface above cooktop
L.
2" (5.1 cm) minimum clearance between back wall and countertop
cutout
M. Gas line opening - Wall: anywhere 6" (15.2 cm) below underside of
countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is
recommended.
N. 25" (63.5 cm) depth of countertop
NOTE: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
� A minimum side clearance of 6" (15.2 cm) is recommended
between side of cooktop and side wall for maximum ventilation
performance.
Cutout Dimensions
A. 28
5
/
" (72.7 cm) maximum on 30" (76.2 cm) models
8
34
3
/
" (88.3 cm) maximum on 36" (91.4 cm) models
4
B. 19
15
/
" (50.6 cm) maximum on both 30" (76.2 cm) and
16
36" (91.4 cm) models
C. 7
7
/
" (20.0 cm) on 30" (76.2 cm) models
8
16
3
/
" (41.1 cm) on 36" (91.4 cm) models
16
D. 5
3
/
" (14.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models
4
E. 2
1
/
" (5.4 cm) minimum space to front edge of cooktop
8
F.
Floor exhaust option
G. 6
1
/
" (15.6 cm) for 6" (15.2cm) vent system
8
H. 7
7
/
" (20.0 cm) on 30" (76.2 cm) models
8
16
3
/
" (41.1 cm) on 36" (91.4 cm) models
16
I.
14
11
/
" (37.3 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models
16
J.
Wall exhaust option

Venting Requirements

IMPORTANT: This cooktop must be exhausted outdoors unless
using the Duct-Free Filter Accessory Kit. See the "Venting
Methods" section.
� Do not terminate the vent system in an attic or other enclosed
area.
� Use a vent cap.
� Vent system must terminate to the outside.
� Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is
recommended. For best performance, do not use plastic or
metal foil vent.
� Before making cutouts, make sure there is proper clearance
within the wall or floor for the exhaust vent.
� Do not cut a joist or stud unless absolutely necessary. If a joist
or stud must be cut, then a supporting frame must be
constructed.
� The size of the vent should be uniform.
� The vent system must have a damper.
� Use vent clamps to seal all joints in the vent system.
� Use caulking to seal exterior wall or roof opening around the
cap.
� Determine which venting method is best for your application.