SCE100 Series Signal Conditioner Enclosure
SCE100 Series Signal Conditioner Enclosure
4 Channel
4 Channel
Product Manual
Product Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the SCE100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for CTC Union SCE100 Series

  • Page 1 SCE100 Series Signal Conditioner Enclosure SCE100 Series Signal Conditioner Enclosure 4 Channel 4 Channel Product Manual Product Manual...
  • Page 2: Table Of Contents

    Table of Contents • Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 •...
  • Page 3: Introduction

    Introduction This document contains information on the operation, installation and maintenance of the SCE Series Signal Conditioner Enclosure . This manual is an overview of the system and references the specific component manuals . User manuals are provided with the system for all configurable internal components . Product Overview The SCE Series Signal Conditioner Enclosure is a turnkey solution coming fully populated with signal conditioners, power supply, and terminal blocks for...
  • Page 4: Product Dimensions & Diagram

    Product Dimensions 11.90 in [302.2 mm] 6.84 in 9.03 in [173.7 mm] [229.3 mm] 13.77 in 12.85 in [349.8 mm] [326.3 mm] Front View Side View Figure 1. Dimensions Figure 2. Diagram...
  • Page 5: Mounting Instructions

    Mounting Instructions Independant stainless steel mounting feet are included on the enclosure . Wall anchoring screws are not included . Note: if you have purchased a SCE100 series enclosure without cable entries provided, you should add your own entry prior to mounting the enclosure .
  • Page 6: Conduit Entry

    Note: To ensure moisture will not flow into the enclosure, a hole should be drilled at the lowest point in the conduit to provide drainage for any moisture . Correct Incorrect Drill Drain Hole Here Figure 4. Conduit Entry for SCE100 Series...
  • Page 7: Grounding

    Grounding Ensure the shield ground wire on the SCE100 Series enclosure is grounded to earth ground . A. Mounting to Earth Ground When mounting SCE100 Series enclosures to earth ground (such as an I-Beam), mount the shield ground wire using a mounting bolt through one of the mounting brackets on the enclosure .
  • Page 8 B. Mounting to non-grounded structure When mounting the SCE100 series enclosure to a non-grounded structure, ensure the shield ground wire or customer supplied ground wire is tied to a source of earth ground . Figure 6. Ground Wire Placement...
  • Page 9: Electrical Connections

    Electrical Connectons Cables enter and exit the enclosure through conduit fittings or cord grips on the bottom of the unit . All input and output wiring is connected to the terminal blocks and signal conditioners inside the unit . Inputs are routed through a conduit fitting or cord grips (1 per channel), output wiring is routed through a conduit fitting .
  • Page 10 . All wires are connected to terminal blocks within the enclosure . Sensor inputs for the SCE100 series are located on the right side of the enclosure as indicated by the interior labeling “Sensor Input .”...
  • Page 11 Input for Vibration and Temperature Data Four Signal Pole Conditioner Terminal Terminal Block Block Cable Position Position Color Destination Signal (+) Black Common Green Shield Drain White Temperature Note: If there is no sensor wired to the sensor input terminal, the corresponding transmitter for that channel will not power on .
  • Page 12: Troubleshooting

    Wiring Outputs The 4-20mA output of the SCE100 series are located on the left side of the enclosure as indicated by the interior labeling “Output .” SCE111 — Signal Conditioners with Single Vibration Band Output Four Signal Pole Conditioner Terminal...
  • Page 13 SCE112 — Signal Conditioners with Single Vibration Band and Temperature Outputs Four Signal Pole Conditioner Terminal Terminal Block Block Cable Position Position Color Destination Channel 1 Output Black Common White Temperature Output...
  • Page 14 SCE113 — Signal Conditioners with Dual Vibration Band Output Four Signal Pole Conditioner Terminal Terminal Block Block Cable Position Position Color Destination Channel 1 Output Black Common Blue Channel 2 Output...
  • Page 15 SCE114 — Signal Conditioners with Dual Vibration Band and Temperature Outputs Four Signal Pole Conditioner Terminal Terminal Block Block Cable Position Position Color Destination Channel 1 Output Black Common Blue Channel 2 Output White Temperature Output...
  • Page 16 Note: When collecting waveform data from the BNC jack on the signal conditioner using a portable data collector that supplies constant current power, it is recommended that the data collector is configured so that power to the sensor is turned off . Although the BNC connector circuitry offers short circuit protection and can safely sink the current, long-term degradation may occur due to increased power dissipation depending on the magnitude of the IEPE current .
  • Page 17 A short circuit is indicative of a lack of electrical resistance, removing the ability to measure the impact from a change in voltage . This instance is largely driven by an incorrect wiring setup . Verify that all wiring connections are attached in the correct polarity, and that no signal and common wires are touching .
  • Page 18 This state occurs when the signal conditioner starts up, confirms there is an available configuration, and sets up its peripherals and outputs . If the USB cable is connected and plugged into a PC, this state will persist . Plugging in the USB cable at any point will also cause the device to enter this state .