CTC Union XE150 Product Manual
CTC Union XE150 Product Manual

CTC Union XE150 Product Manual

Enclosure for sc200 series premium signal conditioners

Advertisement

Quick Links

Product Manual
MNX10030 / REV 0
MODEL XE150
Enclosure for SC200 Series Premium
Signal Conditioners

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XE150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CTC Union XE150

  • Page 1 Product Manual MNX10030 / REV 0 MODEL XE150 Enclosure for SC200 Series Premium Signal Conditioners...
  • Page 2: Table Of Contents

    Contents Section I Overview Introduction..............….… 2 Description................2 Section II Installation Mounting………............... 4 Electrical Connections............. 5 Section III Operation Operating Procedure............... 6 Section IV Maintenance General..................8 Warranty.................. 8 Figures Figure 1 (Selection Guide)……………………...………………...3 Figure 2 (Mounting Bracket Location)........4 Figure 3 (Conduit Entry Layout).……………….……………..…...
  • Page 3: Section I

    10 VDC output and a 4-20mA output and a temperature output in 0-1.2 VDC) and ± sensor input (vibration, displacement and temperature inputs) these connections are based upon the XE150 variant ordered. There is also a green indicator light (Transducer Signal OK) which illuminates when the sensor is properly connected to the transmitter and working correctly.
  • Page 4: Figure 1 (Selection Guide)

    • Specifications on a particular Signal Conditioner may be obtained from the unit's label or by calling an Application Engineer for more information. Selection Guide Below is a guide to help select which XE150 series enclosure fits your specific requirements. Figure 1. Selection Guide...
  • Page 5: Installation Mounting

    Section II Installation Mounting 1. Attach the enclosed mounting brackets to the NEMA enclosure at the predetermined locations (if applicable). CTC Vibration Mounting Enclosure Brackets Figure 2. Mounting Bracket Location 2. Conduit Entry: If you are running conduit to your enclosure, CTC recommends the conduit cable entry from the bottom of the enclosure when mounted.
  • Page 6: Electrical Connections

    Outputs The 4-20mA output of the XE150 and XE150T are located on the left side of the enclosure as indicated by the labeling “4-20mA Output”. These terminal blocks follow the same scheme as the inputs – Standard XE150 using 3 position terminal blocks and the XE150T using 4 position terminal blocks.
  • Page 7: Operation

    Section III Operation Power AC power for the small enclosure and the large enclosures (for both XE150 and XE150T) enters the enclosure through a ½” conduit fitting and is connected directly to the power supply. Signal Conditioner Configuration Refer to MNX10020 for configuration specifications and procedure for SC200 signal conditioners.
  • Page 8 Indicators The LED on the front of the Signal Conditioner will indicate the status of the Signal Conditioner. A constant bright LED indicates normal operating condition, and a Flashing LED indicates an error has occurred. STATE 1 – “Normal” Mode Operation •...
  • Page 9: Maintenance

    Section IV Maintenance General There are no customer replaceable parts. It should provide trouble-free continuous service under normal operating conditions. Warranty If any PRO product should ever fail, we will repair or replace it at no charge, as long as the product was not subjected to misuse, natural disasters, improper installation or modification which caused the defect.