Delta Environmental Products DE33 Series Installation, Operation & Parts Manual

Submersible solids handling pumps
Table of Contents

Advertisement

Available languages

Available languages

8275 Florida Blvd. • Denham Springs, LA 20726
Submersible Solids
Handling Pumps
INSTALLATION, OPERATION, & PARTS MANUAL
SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for
personal injury!
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
1. Read these rules and instructions carefully. Failure to
follow them could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing. You must com-
ply with their rules.
3. Vent sewage or septic tank according to local codes.
MOTOR, SWITCH, & CORD SPECIFICATIONS
Model
Motor
Number
HP
DE33-20-A1
1/3
DE33-20-M1
1/3
DE40H-20-A1
4/10
DE40H-20-M1
4/10
DS40-20-A1
4/10
DS50-20-A1
1/2
DS50-20-M1
1/2
DS50F-20-A1
1/2
DS50F-20-M1
1/2
© 2009
Motor
Full
Voltage
Load Amps
115/1
13.0
115/1
13.0
115/1
9.7
115/1
9.7
115/1
12.5
115/1
13.0
115/1
13.0
115/1
9.0
115/1
9.0
4. Do not install pump in any location classified as haz-
ardous by National Electrical Code, ANSI/NFPA 80-1984
or the Canadian Electrical Code.
burn, or kill. During operation the pump is in water.
To avoid fatal shocks, proceed as follows if pump needs
servicing:
5A. Disconnect power to outlet box before unplugging pump.
5B. Take extreme care when changing fuses. Do not stand
in water or put your finger in the fuse socket.
5C. Do not modify the cord and plug. When using the cord
and plug, plug into a grounded outlet only. When wiring
to a system control, connect the pump ground lead to
the system ground.
6. Do not run the pump dry. Dry running can overheat the
pump, (causing burns to anyone handling it) and will
void the warranty.
7. The pump normally runs hot. To avoid burns when ser-
vicing pump, allow it to cool for 20 minutes after shut-
down before handling it.
8. The pump is permanently lubricated. No oiling or greas-
ing is required in normal operation. for overhaul, see
instructions under "Service".
Individual
Cord
Branch Circuit
Length
Required (Amps)
in ft. (m)
20
20 (6.1)
20
20 (6.1)
15
15 (4.6)
15
15 (4.6)
20
20 (6.1)
20
20 (6.1)
20
20 (6.1)
10
20 (6.1)
10
20 (6.1)
DE33/DE40H/DS40/
DS50/DS50H Series
Hazardous voltage. Can shock,
Switch Setting
in inches (mm)
On
Off
13.5 (343)
4.5 (114)
16.5 (419)
7.5 (191)
16 (406)
7 (178)
16 (406)
7 (178)
18 (457)
8.5 (216)
Discharge
Adapter
Size
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
2"
DE504 (7/14/09)

Advertisement

Table of Contents
loading

Summary of Contents for Delta Environmental Products DE33 Series

  • Page 1 DE33/DE40H/DS40/ DS50/DS50H Series 8275 Florida Blvd. • Denham Springs, LA 20726 Submersible Solids Handling Pumps INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION 4. Do not install pump in any location classified as haz- ardous by National Electrical Code, ANSI/NFPA 80-1984 Carefully read and follow all safety instructions in this or the Canadian Electrical Code.
  • Page 2: Specifications

    DESCRIPTION In a sewage system use a 2" (51mm) check valve in pump dis- charge to prevent backflow of liquid into sump basin. The check These submersible sump/effluent and sewage pumps are valve should be a free flow valve that will easily pass solids. Be designed for effluent and wastewater removal, sump drainage, sure check valve installation complies with local codes.
  • Page 3: Operation

    OPERATION 3. Remove the capscrews holding the lower motor hous- ing to the volute; lift off the lower motor housing. 4. Hold the rotor shaft assembly and unscrew the Risk of fire or explosion. Can cause severe impeller by turning it counter-clockwise. Remove personal injury, property damage or death.
  • Page 4 Pump Disassembly DE33/DS50 Series Oil Fill Plug Power Cord Housing O-Ring Capscrew Insulating Lower Disk Motor Housing Rotor/Stator Assembly Shaft Seal, Stator Stationary Capscrew Head Ass’y Shaft Seal, Rotating Mating Ring Impeller Volute 410 0893 Pump Disassembly – DE40H Series Rotor/Stator Capscrew Spacer...
  • Page 5 Pump Disassembly – DS40 Series Oil Fill Plug Switch Cord Clamp Capscrews Upper Motor Housing Insulating Disk Lower Motor Housing Shaft Seal, Stationary Head Assembly Shaft Seal, Rotating Mating Ring Impeller Volute 3917 0301 Disassmbly Pump Disassembly – DS50F Series Power cord Rotor/Stator connector...
  • Page 6: Repair Parts List

    DE33/DS50 SERIES EXPLODED VIEW REPAIR PARTS LIST DE33-20-M1 DS50-20-M1 Part DE33-20-A1 DS50-20-A1 Description Qty. 1/3 HP 115 V 1/2 HP 115V Power Cord PW117-122-TSE PW117-122-TSE Cord Connector PS17-46P PS17-46P Handle Ring U97-128 U97-128 1/4" NPT Plug U78-57DT U78-57DT Upper Motor Housing PW18-22F PW18-22F #10-32 x 3/4"...
  • Page 7 DE40H SERIES EXPLODED VIEW 1050 0797 EC4 REPAIR PARTS LIST DE40H-20-M1 Part DE40H-20-A1 Description 4/10 HP 115V Power Cord PW117-122-TSE Automatic Float Switch* PS117-126P Cord Connector PS17-46P #8-32 x 1/2” Capscrew* U30-539SS Switch Cord Clamp* CC0030-13 Handle Ring U97-128 1/4" NPT Plug U78-57DT Upper Motor Housing PW18-133...
  • Page 8 DS40 SERIES EXPLODED VIEW REPAIR PARTS LIST Part DS40-20-A1 Description 4/10 HP 115V Power Cord PW117-122-TSE Cord Connector PS17-46P O-Ring U9-370 #10-32 x 3/4" Capscrew U30-482SS Upper Motor Housing O-Ring U9-339 Insulating Disk PS18-82 Lower Motor Housing Shaft Seal, Stationary Head Assembly U9-379A Shaft Seal, Rotating Mating Ring...
  • Page 9 DS50F SERIES EXPLODED VIEW 3310 0898 SC6 REPAIR PARTS LIST DS50F-20-M1 Part DS50F-20-A1 Description 1/2 HP 115V Power Cord PW117-122-TSE Cord Connector PS17-46P 1/4" NPT Plug U78-57DT Handle Ring U97-128 Upper Motor Housing PW18-133 #10-32 x 3/4" Capscrew U30-482SS Capacitor U18-1590 #10-32 x 4-1/4"...
  • Page 10: Limited Warranty

    LIMITED WARRANTY Delta Environmental Products (“Delta”) warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product...
  • Page 11 Series DE33/DE40H/DS40/ DS50/DS50H 8275 Florida Blvd. • Denham Springs, LA 20726 Bombas sumergibles para el manejo de partículas sólidas MANUAL DE INSTALACIÓN, OPERACIÓN Y REPUESTOS INFORMACIÓN SOBRE No instale la bomba en ningún lugar clasificado como peligroso por el Código Eléctrico Nacional, la norma 80-1984 de LA SEGURIDAD ANSI/NFPA o el Código Eléctrico Canadiense.
  • Page 12: Especificaciones

    DESCRIPCIÓN En un sistema de aguas residuales, use una válvula de retención de 2" (51 mm) en la descarga de la bomba para evitar retroflujo de líquido a Estas bombas sumergibles para sumideros, efluente y aguas resid- la esclusa del sumidero. La válvula de retención deberá ser una válvula uales han sido diseñadas para la remoción de efluente y aguas resid- de flujo libre que pueda pasar partículas sólidas con facilidad.
  • Page 13: Operación

    OPERACIÓN Saque los tornillos prisioneros que sostienen la caja inferior del motor a la voluta; levante y saque la caja inferior del motor. ADVERTENCIA Sostenga la unidad del eje de rotor y destornille el impulsor Riesgo de incendio o de explosión. haciéndolo girar en la dirección opuesta a las agujas del Puede causar lesiones graves, daños materiales o muerte.
  • Page 14 Desensamblaje de la bomba Series DE33/DS50 Oil Fill Tapón de relleno Plug Cordón de de aceite Power Cord corriente Tornillo Housing prisionero Aro Tórico O-Ring Capscrew de la caja Insulating Disco Lower Disk aislador Caja inferior Motor del motor Housing Rotor/Stator Unidad del rotor/estator...
  • Page 15 Desensamblaje de la bomba Serie DS40 Tapon de Oil Fill relleno Plug de aceite Abrazadera del cordón del comnutador Switch Cord Clamp Tornillos Capscrews Caja superior Upper Motor Housing del motor Disco aislador Insulating Disk Caja inferior Lower Motor Housing del motor Ensamblaje del cabezal fijo del eje sellado Shaft Seal, Stationary Head Assembly...
  • Page 16 VISTA AGRANDADA DE LAS SERIES DE33/DS50 LISTA DE REPUESTOS PARA REPARACIONES DE33-20-M1 DS50-20-M1 Clave DE33-20-A1 DS50-20-A1 Descripción de la pieza Cant. 1/3 CV 115 V 1/2 CV 115V Cordón de corriente PW117-122-TSE PW117-122-TSE Conector del cordón PS17-46P PS17-46P Manija anular U97-128 U97-128 Enchufe de 1/4"...
  • Page 17 VISTA AGRANDADA DE LAS SERIES DE40H 1050 0797 EC4 LISTA DE REPUESTOS PARA REPARACIONES DE40H-20-M1 Clave Descripción DE40H-20-A1 de la pieza Cant 4/10 CV 115V Cordón de corriente PW117-122-TSE Conmutador automático de flotación * PS117-126P Conector del cordón PS17-46P Tornillo prisionero #8 – 32 x 1/2" U30-539SS Abrazadera del cordón del conmutador * CC0030-13...
  • Page 18 VISTA AGRANDADA DE LAS SERIES DS40 LISTA DE REPUESTOS PARA REPARACIONES Clave Descripción DS40-20-A1 de la pieza Cant. 4/10 CV 115V Cordón de corriente PW117-122-TSE Conector del cordón PS17-46P Aro tórico U9-370 Tornillo prisionero #10 – 32 x 3/4" U30-482SS Caja superior del motor Aro tórico U9-339...
  • Page 19 VISTA AGRANDADA DE LA SERIE DS50F 3310 0898 SC6 LISTA DE REPUESTOS PARA REPARACIONES DS50F-20-M1 Clave DS50F-20-A1 Descripción de la pieza Cant. 1/2 CV 115V Cordón de corriente PW117-122-TSE Conector del cordón PS17-46P Enchufe de 1/4" NPT U78-57DT Manija anular U97-128 Caja superior del motor PW18-133...
  • Page 20: Problemas - Soluciones

    GARANTÍA LIMITADA Delta Environmental Products (“Delta”) le garantiza al comprador/consumidor original (“Comprador” o “Usted”) de los productos enumerados abajo, que estos estarán libres de defectos en material y mano de obra durante el Período de Garantía indicado a continuación.

Table of Contents