3. Press the add key
4. Press the subtract key
5. Press the measure function key
specified length. The display shows "- - - - -".
6. Press and hold the measure key
activate the continuous measuring mode.
The laser distance meter now continuously measures the dis-
tance. The results are shown continuously on the display. If the
measured distance is shorter than the specified length, an
(8) appears on the display. If the measured distance is greater
than the specified length, an
When approaching to the specified length, beeps are heard in
short intervals. When the specified length exactly has been
reached, slow and continuous beeps are heard.
7. Press the measure key
(H) to quit the stake-out mode.
Memory Recall
The laser distance meter stores values of the last 20 measured
distances in the internal memory.
1. Press and hold the countdown/memory key
seconds to activate the memory recall function.
2. Use the add key
the stored values. The memory counter (11) shows the current
memory number.
3. Press the power key
Using
(C) to increase the flashing digit.
(G) to decrease the flashing digit.
icon (8) appears on the display.
(B) and then press the power key
(C) and the subtract key
(H) to quit the memory recall mode.
26
(D) to finish entering the
(B) for approx. 2 seconds to
(E) for approx.2
icon
(G) to recall