Download Print this page

Hitachi CR12V Disassembly And Reassembly page 9

Saber saw
Hide thumbs Also See for CR12V:

Advertisement

For N.Z.:
1-4. Remaingin Reassembly:
Remaining reassembly can be accomplished by following the disassembly procedures in reverse.
1-5. Insulation Tests:
On completion of disassembly and repair, carefully measure the insulation resistance and conduct
dielectric strength test.
Insulation Resistance: 7MΩ or more with 500V DC Megohm Tester
Dielectric Strength:
AC 4000V/1 minute, with no abnormalities ................... 220V - 240V
AC 2500V/1 minute, with no abnormalities ................... 110V - 127V
Fig. 17
− 8 −
Trigger Switch
Noise Suppressor
Choke Coil
(and 110V for U.K. products)
(except U.K. products)