Pump Setup - Ace ACE5S 1/2 HP Installation Manual

Jet pumps
Table of Contents

Advertisement

Available languages

Available languages

Installation

Pump Setup

NOTE: Pump may be supplied attached to a shipping pallet.
Inspect pump for visible signs of damage. Remove and discard
pallet from pump before installation.
IMPORTANT: SELECT CORRECT
VOLTAGE
Ensure pump circuit breaker is OFF and pump is disconnected
from power source before changing the pump voltage.
To change the voltage, the selector switch is located underneath
the access cover on the end of the motor. To access the switch,
remove the two screws holding the cover. To change the voltage
setting, turn the dial with a nut driver or a wrench so the correct
Power Supply Connections
Voltage
Change
Dial
Ground Wire Connection
Voltage Set to 230 Volts
Voltage Set to 115 Volts
WIRING CHART – RECOMMENDED WIRE AND FUSE SIZES
Motor
Model
HP
Volts
ACE5S
1/2
115/230
ACE5C
ACE10S
1
115/230
ACE10C
1
115/230
*Time delay fuse or circuit breakers are recommended in any motor circuit.
Pressure Switch
Nameplate
Branch Fuse
Amps
Rating* Amp
12.4/6.2
20/15
18.6/9.3
20/15
14.8/7.4
20/15
voltage shows in the cutout in the dial. The voltage number that
appears is the voltage setting for the pump. Replace the cover
and secure it with the screws.
WIRING YOUR PUMP
Ensure pump circuit breaker is OFF and pump is disconnected
from power before servicing or handling pump.
Remove the cover from the pressure switch. Connect the bare
copper ground to the ground screw in the pressure switch.
Connect the power supply to the terminals marked "From Line"
in the diagram below.
Ground
Connections
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 100
101 - 200
(0 - 30)
(31 - 61)
AWG WIRE SIZE (mm
12/14(3/2)
10/14(5.5/2)
12/14(3/2)
18/14(8.4/2)
12/14(3/2)
8/14(8.4/2)
3
To Motor
From Line
5907 1108
201 - 300
301 - 400
(62 - 91)
(92 - 122)
)
2
8/14(8.4/2)
6/12(14/3)
6/14(14/2)
6/12(14/3)
6/14(14/2)
6/12(14/3)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents