19. Cleaning the shower head base

19.1 Undo the screw using a hexagonal wrench.
19.2 With a screwdriver, carefully lever out the jet base.
19.3 Clean the shower head base.
19.4 Reassemble in reverse order.

20. Replacing a filter

Water volume regulator filter
20.1 Remove the shower panel (see
20.2 Unscrew the locking screws (a) on the water volume regulators.
20.3 Replace the filters (b).
Important!
Note the installation position of the filters.
20.4 Reassemble in reverse order.

21. Replacing the flow rate regulator

21.1 Undo the grub screw with a hexagonal wrench.
21.2 Pull the shower head out of the connection pipe.
21.3 Remove the locking ring on the inside using appropriate pliers for locking rings.
21.4 Pull out the flow rate regulator using flat-nosed pliers.
21.5 Replace the flow rate regulator. Heed the table.
Flow rate
0.15 l/s (orange)
0.20 l/s (red)
Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
21.6 Insert the flow rate regulator and secure with the locking ring.
a: Struts
b: Direction of flow
21.7 Reassemble in reverse order.
Chapter
Flow rate regulator
FAR order no. 2000104782
FAR order no. 2000104783
- 12 -