For Alpha Intec –
Gain access to the boiler terminal block as described in the boiler installation
and service instructions.
Pass the wire from the Climatic controller through the rubber grommet in the
terminal block cover
Connect it to terminals 12 & 13.
Remove link wire from terminals 1 & 2
(DO NOT connect Climatic wires into terminals 1 & 2!)
Secure the wire under the cable clamp and re-assemble in reverse order.
For Alpha Intec –
Gain access to the boiler terminal block as described in the boiler installation
and service instructions.
Remove the screws from the fixing posts in the back of the control panel,
position the receiver and re-fit the screws to secure it in place.
Connect the wires from the receiver terminal to the BUS connections 12 & 13
on the boiler terminal block (the wires can be connected either way round).
Hard Wired
RF Wireless
8